1
-
-
28844479458
-
Characteristics of high frequency signal propagation within a transformer winding model using transfer function analysis and experimental evaluation
-
February
-
B Han, P L Lewin, Y Tian and P Jarman "Characteristics of high frequency signal propagation within a transformer winding model using transfer function analysis and experimental evaluation" IEE Proc Int Conf on Reliability of Transmission and Distribution Networks, pp99-103, February 2005
-
(2005)
IEE Proc Int Conf on Reliability of Transmission and Distribution Networks
, pp. 99-103
-
-
Han, B.1
Lewin, P.L.2
Tian, Y.3
Jarman, P.4
-
3
-
-
34249663354
-
-
th ed Butterworth and Co Ltd, 1983
-
th ed Butterworth and Co Ltd, 1983
-
-
-
-
4
-
-
0025593766
-
The detection of partial discharge activities within power transformers using computer aided acoustic emission techniques
-
S L Jones "The detection of partial discharge activities within power transformers using computer aided acoustic emission techniques" IEEE ISEI, pp106-110. 1990
-
(1990)
IEEE ISEI
, pp. 106-110
-
-
Jones, S.L.1
-
5
-
-
0001483660
-
Transformer monitoring using the UHF technique
-
August
-
M D Judd, B M Prior, S C Kelly and B F Hampton "Transformer monitoring using the UHF technique" International Symposium on High Voltage Engineering, Vol 5, pp362-365, August 1999
-
(1999)
International Symposium on High Voltage Engineering
, vol.5
, pp. 362-365
-
-
Judd, M.D.1
Prior, B.M.2
Kelly, S.C.3
Hampton, B.F.4
-
6
-
-
28844505693
-
Measurement of discharge signal propagation within a dry-type transformer model
-
February
-
B Han, P L Lewin, Y Tian, Z D Wang and P Jarman "Measurement of discharge signal propagation within a dry-type transformer model" IEE Proc Int Conf on Reliability of Transmission and Distribution Networks, pp161-165, February 2005
-
(2005)
IEE Proc Int Conf on Reliability of Transmission and Distribution Networks
, pp. 161-165
-
-
Han, B.1
Lewin, P.L.2
Tian, Y.3
Wang, Z.D.4
Jarman, P.5
-
7
-
-
28844492190
-
Partial discharge measurements on a 400kV cable joint using optical modulation techniques
-
February
-
Y Tian, P L Lewin, G Schroeder, J S Wilkinson and S J Sutton "Partial discharge measurements on a 400kV cable joint using optical modulation techniques" IEE Proc Int Conf on Reliability of Transmission and Distribution Networks, pp283-286, February 2005
-
(2005)
IEE Proc Int Conf on Reliability of Transmission and Distribution Networks
, pp. 283-286
-
-
Tian, Y.1
Lewin, P.L.2
Schroeder, G.3
Wilkinson, J.S.4
Sutton, S.J.5
-
8
-
-
33845893205
-
Partial Discharge Monitoring of Power Transformers
-
PhD Thesis, University of Southampton
-
B. Han, "Partial Discharge Monitoring of Power Transformers" PhD Thesis, University of Southampton, 2004
-
(2004)
-
-
Han, B.1
-
9
-
-
28744438034
-
Procedure for Identification and Localization of Dangerous PD Sources in Power Transformers
-
J Fuhr, "Procedure for Identification and Localization of Dangerous PD Sources in Power Transformers" IEEE Trans DEIS, 12(5), p1005-1114, 2005
-
(2005)
IEEE Trans DEIS
, vol.12
, Issue.5
, pp. 1005-1114
-
-
Fuhr, J.1
|