메뉴 건너뛰기




Volumn 37, Issue 2, 2007, Pages 97-102

Spatial localization of EEG electrodes

Author keywords

EEG sensor; Electroencephalography, EEG; Magnetic Resonance Imaging, MRI; Source localization; Spatial localization

Indexed keywords

ARTICLE; BIOSENSOR; DIGITAL IMAGING; ELECTRODE; ELECTROENCEPHALOGRAPHY; ELECTROMAGNETIC FIELD; HEAD; NUCLEAR MAGNETIC RESONANCE IMAGING; PHOTOGRAPHY; SIGNAL DETECTION; THREE DIMENSIONAL IMAGING; ULTRASOUND;

EID: 34249331722     PISSN: 09877053     EISSN: 17697131     Source Type: Journal    
DOI: 10.1016/j.neucli.2007.03.002     Document Type: Article
Times cited : (75)

References (16)
  • 2
    • 0021842454 scopus 로고
    • Ten percent electrode system for topographic studies of spontaneaous and evoked EEG activity
    • Chatrian G.E., Lettich E., and Nelson P.L. Ten percent electrode system for topographic studies of spontaneaous and evoked EEG activity. Am J EEG Technol 25 (1985) 83-92
    • (1985) Am J EEG Technol , vol.25 , pp. 83-92
    • Chatrian, G.E.1    Lettich, E.2    Nelson, P.L.3
  • 5
    • 0000147667 scopus 로고
    • The ten twenty electrode system of the International Federation
    • Jasper H.H. The ten twenty electrode system of the International Federation. Electroencephalogr Clin Neurophysiol 10 (1958) 371-375
    • (1958) Electroencephalogr Clin Neurophysiol , vol.10 , pp. 371-375
    • Jasper, H.H.1
  • 7
    • 0032923116 scopus 로고    scopus 로고
    • Spatial mislocalization of EEG electrodes-effects on accuracy of dipole estimation
    • Khosla D., Don M., and Kwong B. Spatial mislocalization of EEG electrodes-effects on accuracy of dipole estimation. Clin Neurophysiol 110 (1999) 261-271
    • (1999) Clin Neurophysiol , vol.110 , pp. 261-271
    • Khosla, D.1    Don, M.2    Kwong, B.3
  • 9
    • 0031803082 scopus 로고    scopus 로고
    • A rapid method for determining standard 10/10 electrode positions for high resolution EEG studies
    • Le J., Lu M., Pellouchoud E., and Gevins A. A rapid method for determining standard 10/10 electrode positions for high resolution EEG studies. Electroencephalogr Clin Neurophysiol 106 (1998) 554-558
    • (1998) Electroencephalogr Clin Neurophysiol , vol.106 , pp. 554-558
    • Le, J.1    Lu, M.2    Pellouchoud, E.3    Gevins, A.4
  • 10
    • 0035084667 scopus 로고    scopus 로고
    • the five percent electrode system for high-resolution EEG and ERP measurements
    • Oostenveld R., and Praamstra P. the five percent electrode system for high-resolution EEG and ERP measurements. Clin Neurophysiol 112 (2001) 713-719
    • (2001) Clin Neurophysiol , vol.112 , pp. 713-719
    • Oostenveld, R.1    Praamstra, P.2
  • 11
  • 13
    • 34249279104 scopus 로고
    • A new device for scalp electrode localization with unrestrained head
    • Steddin S., and Bötzel K. A new device for scalp electrode localization with unrestrained head. J Neurol 242 (1995) 65
    • (1995) J Neurol , vol.242 , pp. 65
    • Steddin, S.1    Bötzel, K.2
  • 14
    • 0027214741 scopus 로고
    • Spatial sampling of head electrical fields: the geodesic sensor net
    • Tucker D.M. Spatial sampling of head electrical fields: the geodesic sensor net. Electroencephalogr Clin Neurophysiol 87 (1993) 154-163
    • (1993) Electroencephalogr Clin Neurophysiol , vol.87 , pp. 154-163
    • Tucker, D.M.1
  • 15
    • 0030175675 scopus 로고    scopus 로고
    • An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head
    • Wang Y., Maurer C., and Fitzpatrick J. An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head. IEEE Trans Biomed Eng 43 6 (1996) 627-637
    • (1996) IEEE Trans Biomed Eng , vol.43 , Issue.6 , pp. 627-637
    • Wang, Y.1    Maurer, C.2    Fitzpatrick, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.