-
2
-
-
0021235571
-
Burn depth estimation-man or machine
-
Heimbach DM, Afromowitz MA, Engrav LH, Marvin JA, Perry B. Burn depth estimation-man or machine. J Trauma 1984 24 : 373 8.
-
(1984)
J Trauma
, vol.24
, pp. 373-8
-
-
Heimbach, D.M.1
Afromowitz, M.A.2
Engrav, L.H.3
Marvin, J.A.4
Perry, B.5
-
3
-
-
0038784579
-
Noncontact laser doppler imaging in burn depth analysis of the extremities
-
Riordan CL, McDonough M, Davidson JM, Corley RAS, Perlov C, Barton R, Guy J, Nanney LB. Noncontact laser doppler imaging in burn depth analysis of the extremities. J Burn Care Rehabil 2003 24 : 177 86.
-
(2003)
J Burn Care Rehabil
, vol.24
, pp. 177-86
-
-
Riordan, C.L.1
McDonough, M.2
Davidson, J.M.3
Corley, R.A.S.4
Perlov, C.5
Barton, R.6
Guy, J.7
Nanney, L.B.8
-
4
-
-
0035371809
-
Perfusion of burn wounds assessed by laser doppler imaging is related to burn depth and healing time
-
Kloppenberg FW, Beerthuizen GI, ten Duis HJ. Perfusion of burn wounds assessed by laser doppler imaging is related to burn depth and healing time. Burns 2001 27 : 359 63.
-
(2001)
Burns
, vol.27
, pp. 359-63
-
-
Kloppenberg, F.W.1
Beerthuizen, G.I.2
Ten Duis, H.J.3
-
5
-
-
0035063518
-
An audit of the use of laser doppler imaging (LDI) in the assessment of burns of intermediate depth
-
Pape SA, Skouras CA, Byrne PO. An audit of the use of laser doppler imaging (LDI) in the assessment of burns of intermediate depth. Burns 2001 27 : 233 9.
-
(2001)
Burns
, vol.27
, pp. 233-9
-
-
Pape, S.A.1
Skouras, C.A.2
Byrne, P.O.3
-
6
-
-
0141992746
-
Laser doppler imaging determines need for excision and grafting in advance of clinical judgment: A prospective blinded trial
-
Jeng JC, Bridgeman A, Shivnan L, Thornton PM, Alam H, Clarke TJ, Jablonski KA, Jordan MH. Laser doppler imaging determines need for excision and grafting in advance of clinical judgment: a prospective blinded trial. Burns 2003 29 : 665 70.
-
(2003)
Burns
, vol.29
, pp. 665-70
-
-
Jeng, J.C.1
Bridgeman, A.2
Shivnan, L.3
Thornton, P.M.4
Alam, H.5
Clarke, T.J.6
Jablonski, K.A.7
Jordan, M.H.8
-
7
-
-
0028860599
-
Burn depth estimation by use of indocyanine green fluorescence: Initial human trial
-
Sheridan RL, Schomaker KT, Lucchina LC, Hurley J, Yin LM, Tompkins RG, Jerath M, Torri A, Greaves KN, Bue DP. Burn depth estimation by use of indocyanine green fluorescence: initial human trial. J Burn Care Rehabil 1995 16 : 602 4.
-
(1995)
J Burn Care Rehabil
, vol.16
, pp. 602-4
-
-
Sheridan, R.L.1
Schomaker, K.T.2
Lucchina, L.C.3
Hurley, J.4
Yin, L.M.5
Tompkins, R.G.6
Jerath, M.7
Torri, A.8
Greaves, K.N.9
Bue, D.P.10
-
8
-
-
0030178656
-
Fluorescein and burn depth
-
Peled IJ. Fluorescein and burn depth. J Burn Care Rehabil 1996 17 : 378.
-
(1996)
J Burn Care Rehabil
, vol.17
, pp. 378
-
-
Peled, I.J.1
-
9
-
-
0022918947
-
Burn depth evaluation with fluorometry: Is it really definitive?
-
Black KS, Hewitt CW, Miller DM, Ramos E, Halloran J, Bressler V, Martinez SE, Achauer BM. Burn depth evaluation with fluorometry: is it really definitive? J Burn Care Rehabil 1986 7 : 313 7.
-
(1986)
J Burn Care Rehabil
, vol.7
, pp. 313-7
-
-
Black, K.S.1
Hewitt, C.W.2
Miller, D.M.3
Ramos, E.4
Halloran, J.5
Bressler, V.6
Martinez, S.E.7
Achauer, B.M.8
-
11
-
-
0033934846
-
Determination of burn depth with noncontact ultrasonography
-
Iraniha S, Cinat ME, VanderKam VM, Boyko A, Lee D, Jones J, Achauer BM. Determination of burn depth with noncontact ultrasonography. J Burn Care Rehabil 2000 21 : 333 8.
-
(2000)
J Burn Care Rehabil
, vol.21
, pp. 333-8
-
-
Iraniha, S.1
Cinat, M.E.2
Vanderkam, V.M.3
Boyko, A.4
Lee, D.5
Jones, J.6
Achauer, B.M.7
-
12
-
-
0025810048
-
Thermographic assessment of burns using a nonpermeable membrane as wound covering
-
Cole RP, Shakespeare PG, Chissell HG, Jones SG. Thermographic assessment of burns using a nonpermeable membrane as wound covering. Burns 1991 17 : 117 22.
-
(1991)
Burns
, vol.17
, pp. 117-22
-
-
Cole, R.P.1
Shakespeare, P.G.2
Chissell, H.G.3
Jones, S.G.4
-
14
-
-
0017355940
-
Effect of evaporative surface cooling on thermographic assessment of burn depth
-
Anselmo VJ, Zawacki BE. Effect of evaporative surface cooling on thermographic assessment of burn depth. Radiology 1977 123 : 331 2.
-
(1977)
Radiology
, vol.123
, pp. 331-2
-
-
Anselmo, V.J.1
Zawacki, B.E.2
-
15
-
-
0022475401
-
Assessing burn wound depth using in vitro nuclear magnetic resonance (NMR)
-
Koruda MJ, Zimbler A, Settle RG, Jacobs DO, Rolandelli RH, Wolf GL, Rombeau JL. Assessing burn wound depth using in vitro nuclear magnetic resonance (NMR). J Surg Res 1986 40 : 475 81.
-
(1986)
J Surg Res
, vol.40
, pp. 475-81
-
-
Koruda, M.J.1
Zimbler, A.2
Settle, R.G.3
Jacobs, D.O.4
Rolandelli, R.H.5
Wolf, G.L.6
Rombeau, J.L.7
-
16
-
-
0035470991
-
In vivo burn depth determination by high-speed fiber-based polarization sensitive optical coherence tomography
-
Park BH, Saxer C, Srinivas SM, Nelson JS, de Boer JF. In vivo burn depth determination by high-speed fiber-based polarization sensitive optical coherence tomography. J Biomed Opt 2001 6 : 474 9.
-
(2001)
J Biomed Opt
, vol.6
, pp. 474-9
-
-
Park, B.H.1
Saxer, C.2
Srinivas, S.M.3
Nelson, J.S.4
De Boer, J.F.5
-
17
-
-
1642633821
-
Determination of burn depth by polarization-sensitive optical coherence tomography
-
Srinivas SM, de Boer JF, Park H, Keikhanzadeh K, Huang HE, Zhang J, Jung WQ, Chen Z, Nelson JS. Determination of burn depth by polarization-sensitive optical coherence tomography. J Biomed Opt 2004 9 : 207 12.
-
(2004)
J Biomed Opt
, vol.9
, pp. 207-12
-
-
Srinivas, S.M.1
De Boer, J.F.2
Park, H.3
Keikhanzadeh, K.4
Huang, H.E.5
Zhang, J.6
Jung, W.Q.7
Chen, Z.8
Nelson, J.S.9
-
18
-
-
33745388567
-
A critical evaluation of the clinimetrics of laser doppler as a method of burn assessment in clinical practice
-
Chatterjee JS. A critical evaluation of the clinimetrics of laser doppler as a method of burn assessment in clinical practice. J Burn Care Res 2006 27 : 123 30.
-
(2006)
J Burn Care Res
, vol.27
, pp. 123-30
-
-
Chatterjee, J.S.1
-
20
-
-
33646858569
-
Hyperspectral imaging: A new approach to the diagnosis of hemorrhagic shock
-
Cancio LC, Batchinsky AI, Mansfield JR, Panasyuk S, Hertz K, Martini D, Jordan BS, Tracey B, Freeman JE. Hyperspectral imaging: a new approach to the diagnosis of hemorrhagic shock. J Trauma 2006 60 : 1087 95.
-
(2006)
J Trauma
, vol.60
, pp. 1087-95
-
-
Cancio, L.C.1
Batchinsky, A.I.2
Mansfield, J.R.3
Panasyuk, S.4
Hertz, K.5
Martini, D.6
Jordan, B.S.7
Tracey, B.8
Freeman, J.E.9
-
21
-
-
20944448125
-
Can near-infrared spectroscopy identify the severity of shock in trauma patients?
-
Crookes BA, Cohn SM, Bloch S, Amortegui J, Manning R, Li P, Proctor MS, Hallal A, Blackbourne LH, Benjamin R, Soffer D, Habib F, Schulman CI, Duncan R, Proctor KG. Can near-infrared spectroscopy identify the severity of shock in trauma patients? J Trauma 2005 58 : 806 13.
-
(2005)
J Trauma
, vol.58
, pp. 806-13
-
-
Crookes, B.A.1
Cohn, S.M.2
Bloch, S.3
Amortegui, J.4
Manning, R.5
Li, P.6
Proctor, M.S.7
Hallal, A.8
Blackbourne, L.H.9
Benjamin, R.10
Soffer, D.11
Habib, F.12
Schulman, C.I.13
Duncan, R.14
Proctor, K.G.15
-
22
-
-
3042534639
-
Noninvasive muscle oxygenation to guide fluid resuscitation after traumatic shock
-
Crookes BA, Cohn SM, Burton EA, Nelson J, Proctor KG. Noninvasive muscle oxygenation to guide fluid resuscitation after traumatic shock. Surgery 2004 135 : 662 70.
-
(2004)
Surgery
, vol.135
, pp. 662-70
-
-
Crookes, B.A.1
Cohn, S.M.2
Burton, E.A.3
Nelson, J.4
Proctor, K.G.5
-
23
-
-
0035063773
-
Near infrared spectroscopic assessment of hemodynamic changes in the early post-burn period
-
Sowa MG, Leonardi L, Payette JR, Fish JS, Mantsch HH. Near infrared spectroscopic assessment of hemodynamic changes in the early post-burn period. Burns 2001 27 : 241 9.
-
(2001)
Burns
, vol.27
, pp. 241-9
-
-
Sowa, M.G.1
Leonardi, L.2
Payette, J.R.3
Fish, J.S.4
Mantsch, H.H.5
-
24
-
-
0034277354
-
Near-infrared spectroscopy and imaging: A new approach to assess burn injuries
-
Leonardi L, Sowa MG, Payette JR, Mantsch HH. Near-infrared spectroscopy and imaging: a new approach to assess burn injuries. Am Clin Lab 2000 19 : 20 2.
-
(2000)
Am Clin Lab
, vol.19
, pp. 20-2
-
-
Leonardi, L.1
Sowa, M.G.2
Payette, J.R.3
Mantsch, H.H.4
-
25
-
-
0010612190
-
The pathophysiology of inhalation injury
-
In: Herndon, D., editor. Edinburgh: Saunders
-
Traber DL, Herndon DN, Soejima K. The pathophysiology of inhalation injury. In : Herndon D, editor. Total burn care. Edinburgh : Saunders, 2002 : 221 31.
-
(2002)
Total Burn Care.
, pp. 221-31
-
-
Traber, D.L.1
Herndon, D.N.2
Soejima, K.3
-
27
-
-
1642580004
-
Electrical injuries
-
In: Herndon, D., editor. Edinburgh: Saunders
-
Purdue GF, Hunt JL. Electrical injuries. In : Herndon D, editor. Total burn care. Edinburgh : Saunders, 2002 : 455 60.
-
(2002)
Total Burn Care.
, pp. 455-60
-
-
Purdue, G.F.1
Hunt, J.L.2
-
28
-
-
34249281582
-
Chemical burns
-
In: Herndon, D., editor. Edinburgh: Saunders
-
Sanford AP, Herndon DN. Chemical burns. In : Herndon D, editor. Total burn care. Edinburgh : Saunders, 2002 : 475 80.
-
(2002)
Total Burn Care.
, pp. 475-80
-
-
Sanford, A.P.1
Herndon, D.N.2
-
29
-
-
0017324756
-
Non-invasive, infra-red monitoring of cerebral O2 sufficiency, bloodvolume, HbO2-Hb shifts and bloodflow
-
Jobsis FF. Non-invasive, infra-red monitoring of cerebral O2 sufficiency, bloodvolume, HbO2-Hb shifts and bloodflow. Acta Neurol Scand Suppl 1977 64 : 452 3.
-
(1977)
Acta Neurol Scand Suppl
, vol.64
, pp. 452-3
-
-
Jobsis, F.F.1
-
30
-
-
0027236375
-
Towards human brain near infrared imaging: Time resolved and unresolved spectroscopy during hypoxic hypoxia
-
Ferrari M, De Blasi RA, Safoue F, Wei Q, Zaccanti G. Towards human brain near infrared imaging: time resolved and unresolved spectroscopy during hypoxic hypoxia. Adv Exp Med Biol 1993 333 : 21 31.
-
(1993)
Adv Exp Med Biol
, vol.333
, pp. 21-31
-
-
Ferrari, M.1
De Blasi, R.A.2
Safoue, F.3
Wei, Q.4
Zaccanti, G.5
-
31
-
-
0043168162
-
Muscle perfusion and oxygen consumption by near-infrared spectroscopy in septic-shock and non-septic-shock patients
-
Girardis M, Rinaldi L, Busani S, Flore I, Mauro S, Pasetto A. Muscle perfusion and oxygen consumption by near-infrared spectroscopy in septic-shock and non-septic-shock patients. Intensive Care Med 2003 29 : 1173 6.
-
(2003)
Intensive Care Med
, vol.29
, pp. 1173-6
-
-
Girardis, M.1
Rinaldi, L.2
Busani, S.3
Flore, I.4
Mauro, S.5
Pasetto, A.6
-
32
-
-
0031590042
-
Cerebral oxygenation and haemodynamics in the foetus and newborn infant
-
Wyatt JS. Cerebral oxygenation and haemodynamics in the foetus and newborn infant. Philos Trans R Soc Lond B Biol Sci 1997 352 : 697 700.
-
(1997)
Philos Trans R Soc Lond B Biol Sci
, vol.352
, pp. 697-700
-
-
Wyatt, J.S.1
-
34
-
-
0036777425
-
Skin hydration images from near-infrared reflectance spectra
-
Attas EM, Sowa MG, Posthumus TB, Schattka BJ, Mantsch HH, Zhang SL. Skin hydration images from near-infrared reflectance spectra. Am Clin Lab 2002 21 : 32 6.
-
(2002)
Am Clin Lab
, vol.21
, pp. 32-6
-
-
Attas, E.M.1
Sowa, M.G.2
Posthumus, T.B.3
Schattka, B.J.4
Mantsch, H.H.5
Zhang, S.L.6
-
35
-
-
0035173120
-
Visualization of cutaneous hemoglobin oxygenation and skin hydration using near-infrared spectroscopic imaging
-
Attas M, Hewko M, Payette J, Posthumus T, Sowa M, Mantsch H. Visualization of cutaneous hemoglobin oxygenation and skin hydration using near-infrared spectroscopic imaging. Skin Res Technol 2001 7 : 238 45.
-
(2001)
Skin Res Technol
, vol.7
, pp. 238-45
-
-
Attas, M.1
Hewko, M.2
Payette, J.3
Posthumus, T.4
Sowa, M.5
Mantsch, H.6
-
36
-
-
0033111469
-
Noninvasive diagnostics: Predicting flap viability with near-IR spectroscopy and imaging
-
Payette JR, Sowa MG, Germscheid SL, Stranc MF, Abdulrauf B, Mantsch HH. Noninvasive diagnostics: predicting flap viability with near-IR spectroscopy and imaging. Am Clin Lab 1999 18 : 4 6.
-
(1999)
Am Clin Lab
, vol.18
, pp. 4-6
-
-
Payette, J.R.1
Sowa, M.G.2
Germscheid, S.L.3
Stranc, M.F.4
Abdulrauf, B.5
Mantsch, H.H.6
-
37
-
-
0032822694
-
Near-infrared spectroscopic assessment of tissue hydration following surgery
-
Sowa MG, Payette JR, Mantsch HH. Near-infrared spectroscopic assessment of tissue hydration following surgery. J Surg Res 1999 86 : 62 9.
-
(1999)
J Surg Res
, vol.86
, pp. 62-9
-
-
Sowa, M.G.1
Payette, J.R.2
Mantsch, H.H.3
-
38
-
-
0031071661
-
Noninvasive assessment of regional and temporal variations in tissue oxygenation by near-infrared spectroscopy and imaging
-
Sowa MG, Mansfield JR, Scarth GB, Mantsch H. Noninvasive assessment of regional and temporal variations in tissue oxygenation by near-infrared spectroscopy and imaging. Appl Spectrosc 1997 51 : 143 52.
-
(1997)
Appl Spectrosc
, vol.51
, pp. 143-52
-
-
Sowa, M.G.1
Mansfield, J.R.2
Scarth, G.B.3
Mantsch, H.4
-
40
-
-
0027291207
-
Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy
-
De Blasi RA, Cope M, Elwell C, Safoue F, Ferrari M. Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy. Eur J Appl Physiol Occup Physiol 1993 67 : 20 5.
-
(1993)
Eur J Appl Physiol Occup Physiol
, vol.67
, pp. 20-5
-
-
De Blasi, R.A.1
Cope, M.2
Elwell, C.3
Safoue, F.4
Ferrari, M.5
-
41
-
-
0027104006
-
Oxygen consumption of human skeletal muscle by near infrared spectroscopy during tourniquet-induced ischemia in maximal voluntary contraction
-
De Blasi RA, Cope M, Ferrari M. Oxygen consumption of human skeletal muscle by near infrared spectroscopy during tourniquet-induced ischemia in maximal voluntary contraction. Adv Exp Med Biol 1992 317 : 771 7.
-
(1992)
Adv Exp Med Biol
, vol.317
, pp. 771-7
-
-
De Blasi, R.A.1
Cope, M.2
Ferrari, M.3
-
42
-
-
0028850787
-
Near infra-red spectroscopy: A non-invasive monitor of perfusion and oxygenation within the microcirculation of limbs and flaps
-
Irwin MS, Thorniley MS, Dore CJ, Green CJ. Near infra-red spectroscopy: a non-invasive monitor of perfusion and oxygenation within the microcirculation of limbs and flaps. Br J Plast Surg 1995 48 : 14 22.
-
(1995)
Br J Plast Surg
, vol.48
, pp. 14-22
-
-
Irwin, M.S.1
Thorniley, M.S.2
Dore, C.J.3
Green, C.J.4
-
43
-
-
0032054550
-
The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery
-
Thorniley MS, Sinclair JS, Barnett NJ, Shurey CB, Green CJ. The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery. Br J Plast Surg 1998 51 : 218 26.
-
(1998)
Br J Plast Surg
, vol.51
, pp. 218-26
-
-
Thorniley, M.S.1
Sinclair, J.S.2
Barnett, N.J.3
Shurey, C.B.4
Green, C.J.5
-
44
-
-
0024094693
-
Multispectral imaging of burn wounds: A new clinical instrument for evaluating burn depth
-
Afromowitz MA, Callis JB, Heimbach DM, DeSoto LA, Norton MK. Multispectral imaging of burn wounds: a new clinical instrument for evaluating burn depth. IEEE Trans Biomed Eng 1988 35 : 842 50.
-
(1988)
IEEE Trans Biomed Eng
, vol.35
, pp. 842-50
-
-
Afromowitz, M.A.1
Callis, J.B.2
Heimbach, D.M.3
Desoto, L.A.4
Norton, M.K.5
-
45
-
-
0032718652
-
Reflection-optical multispectral imaging method for objective determination of burn depth
-
Eisenbeiss W, Marotz J, Schrade JP. Reflection-optical multispectral imaging method for objective determination of burn depth. Burns 1999 25 : 697 704.
-
(1999)
Burns
, vol.25
, pp. 697-704
-
-
Eisenbeiss, W.1
Marotz, J.2
Schrade, J.P.3
-
46
-
-
0029898556
-
Progressive burn injury documented with vimentin immunostaining
-
Nanney LB, Wenczak BA, Lynch JB. Progressive burn injury documented with vimentin immunostaining. J Burn Care Rehabil 1996 17 : 191 8.
-
(1996)
J Burn Care Rehabil
, vol.17
, pp. 191-8
-
-
Nanney, L.B.1
Wenczak, B.A.2
Lynch, J.B.3
-
47
-
-
0036155281
-
Spectroscopic assessment of cutaneous hemodynamics in the presence of high epidermal melanin concentration
-
Sowa MG, Matas A, Schattka BJ, Mantsch HH. Spectroscopic assessment of cutaneous hemodynamics in the presence of high epidermal melanin concentration. Clin Chim Acta 2002 317 : 203 12.
-
(2002)
Clin Chim Acta
, vol.317
, pp. 203-12
-
-
Sowa, M.G.1
Matas, A.2
Schattka, B.J.3
Mantsch, H.H.4
-
49
-
-
0026254077
-
Non-invasive in vivo near-infrared optical measurement of the penetration depth in the neonatal head
-
Faris F, Thorniley Y, Wickramasinghe Y, Houston R, Rolfe P, Livera N, Spencer A. Non-invasive in vivo near-infrared optical measurement of the penetration depth in the neonatal head. Clin Phys Physiol Meas 1991 12 : 353 8.
-
(1991)
Clin Phys Physiol Meas
, vol.12
, pp. 353-8
-
-
Faris, F.1
Thorniley, Y.2
Wickramasinghe, Y.3
Houston, R.4
Rolfe, P.5
Livera, N.6
Spencer, A.7
|