-
1
-
-
0023554156
-
Measurement of maximal coronary flow reserve: a technique for assessing the physiologic significance of coronary arterial lesions in humans
-
Wilson R.F., and White C.W. Measurement of maximal coronary flow reserve: a technique for assessing the physiologic significance of coronary arterial lesions in humans. Herz 12 (1987) 163-176
-
(1987)
Herz
, vol.12
, pp. 163-176
-
-
Wilson, R.F.1
White, C.W.2
-
2
-
-
0016252480
-
Effects of coronary stenoses on coronary flow reserve and resistance
-
Gould K.L., and Lipscomb K. Effects of coronary stenoses on coronary flow reserve and resistance. Am J Cardiol 34 (1974) 48-55
-
(1974)
Am J Cardiol
, vol.34
, pp. 48-55
-
-
Gould, K.L.1
Lipscomb, K.2
-
3
-
-
0030792911
-
Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography
-
Kaul S., Senior R., Dittrich H., Raval U., Khattar R., and Lahiri A. Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography. Circulation 96 (1997) 785-792
-
(1997)
Circulation
, vol.96
, pp. 785-792
-
-
Kaul, S.1
Senior, R.2
Dittrich, H.3
Raval, U.4
Khattar, R.5
Lahiri, A.6
-
4
-
-
0028860282
-
Detection of coronary stenoses and quantification of the degree and spatial extent of blood flow mismatch during coronary hyperemia with myocardial contrast echocardiography
-
Ismail S., Jayaweera A.R., Goodman N.C., Camarano G.P., Skyba D.M., and Kaul S. Detection of coronary stenoses and quantification of the degree and spatial extent of blood flow mismatch during coronary hyperemia with myocardial contrast echocardiography. Circulation 91 (1995) 821-830
-
(1995)
Circulation
, vol.91
, pp. 821-830
-
-
Ismail, S.1
Jayaweera, A.R.2
Goodman, N.C.3
Camarano, G.P.4
Skyba, D.M.5
Kaul, S.6
-
5
-
-
0029927502
-
Improved myocardial contrast with second harmonic transient ultrasound response imaging in humans using intravenous perfluorocarbon-exposed sonicated dextrose albumin
-
Porter T.R., Xie F., Kricsfeld D., and Armbruster R.W. Improved myocardial contrast with second harmonic transient ultrasound response imaging in humans using intravenous perfluorocarbon-exposed sonicated dextrose albumin. J Am Coll Cardiol 27 (1996) 1497-1501
-
(1996)
J Am Coll Cardiol
, vol.27
, pp. 1497-1501
-
-
Porter, T.R.1
Xie, F.2
Kricsfeld, D.3
Armbruster, R.W.4
-
6
-
-
0035282050
-
Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging
-
Porter T.R., Xie F., Silver M., Kricsfeld D., and Oleary E. Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging. J Am Coll Cardiol 37 (2001) 748-753
-
(2001)
J Am Coll Cardiol
, vol.37
, pp. 748-753
-
-
Porter, T.R.1
Xie, F.2
Silver, M.3
Kricsfeld, D.4
Oleary, E.5
-
7
-
-
0035282040
-
Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography
-
Shimoni S., Zoghbi W.A., Xie F., Kricsfeld D., Iskander S., Gobar L., et al. Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography. J Am Coll Cardiol 37 (2001) 741-747
-
(2001)
J Am Coll Cardiol
, vol.37
, pp. 741-747
-
-
Shimoni, S.1
Zoghbi, W.A.2
Xie, F.3
Kricsfeld, D.4
Iskander, S.5
Gobar, L.6
-
8
-
-
1042264292
-
Assessment of the physiologic significance of coronary disease with dipyridamole real-time myocardial contrast echocardiography: comparison with technetium-99m sestamibi single-photon emission computed tomography and quantitative coronary angiography
-
Peltier M., Vancraeynest D., Pasquet A., Ay T., Roelants V., D'hondt A.M., et al. Assessment of the physiologic significance of coronary disease with dipyridamole real-time myocardial contrast echocardiography: comparison with technetium-99m sestamibi single-photon emission computed tomography and quantitative coronary angiography. J Am Coll Cardiol 43 (2004) 257-264
-
(2004)
J Am Coll Cardiol
, vol.43
, pp. 257-264
-
-
Peltier, M.1
Vancraeynest, D.2
Pasquet, A.3
Ay, T.4
Roelants, V.5
D'hondt, A.M.6
-
9
-
-
0242609059
-
Measurement of myocardial blood flow velocity reserve with myocardial contrast echocardiography in patients with suspected coronary artery disease: comparison with quantitative gated technetium 99m sestamibi single photon emission computed tomography
-
Dawson D., Rinkevich D., Belcik T., Jayaweera A.R., Rafter P., Kaul S., et al. Measurement of myocardial blood flow velocity reserve with myocardial contrast echocardiography in patients with suspected coronary artery disease: comparison with quantitative gated technetium 99m sestamibi single photon emission computed tomography. J Am Soc Echocardiogr 16 (2003) 1171-1177
-
(2003)
J Am Soc Echocardiogr
, vol.16
, pp. 1171-1177
-
-
Dawson, D.1
Rinkevich, D.2
Belcik, T.3
Jayaweera, A.R.4
Rafter, P.5
Kaul, S.6
-
10
-
-
0035967485
-
Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography
-
Wei K., Ragosta M., Thorpe J., Coggins M., Moos S., and Kaul S. Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography. Circulation 103 (2001) 2560-2565
-
(2001)
Circulation
, vol.103
, pp. 2560-2565
-
-
Wei, K.1
Ragosta, M.2
Thorpe, J.3
Coggins, M.4
Moos, S.5
Kaul, S.6
-
11
-
-
0032574674
-
Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography
-
Hozumi T., Yoshida K., Ogata Y., Akasaka T., Asami Y., Takagi T., et al. Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography. Circulation 97 (1998) 1557-1562
-
(1998)
Circulation
, vol.97
, pp. 1557-1562
-
-
Hozumi, T.1
Yoshida, K.2
Ogata, Y.3
Akasaka, T.4
Asami, Y.5
Takagi, T.6
-
12
-
-
17744416887
-
Noninvasive estimation of coronary flow reserve by transthoracic Doppler echocardiography with a high-frequency transducer
-
Hozumi T., Akasaka T., Yoshida K., and Yoshikawa J. Noninvasive estimation of coronary flow reserve by transthoracic Doppler echocardiography with a high-frequency transducer. J Cardiol 37 (2001) 43-50
-
(2001)
J Cardiol
, vol.37
, pp. 43-50
-
-
Hozumi, T.1
Akasaka, T.2
Yoshida, K.3
Yoshikawa, J.4
-
13
-
-
2642537688
-
New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography: comparison with thallium-201 single photon emission computed tomography
-
Fujimoto K., Watanabe H., Hozumi T., Otsuka R., Hirata K., Yamagishi H., et al. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography: comparison with thallium-201 single photon emission computed tomography. J Cardiol 43 (2004) 109-116
-
(2004)
J Cardiol
, vol.43
, pp. 109-116
-
-
Fujimoto, K.1
Watanabe, H.2
Hozumi, T.3
Otsuka, R.4
Hirata, K.5
Yamagishi, H.6
-
14
-
-
11844273943
-
Early recovery of impaired coronary flow reserve by carvedilol therapy in patients with idiopathic dilated cardiomyopathy: a serial transthoracic Doppler echocardiographic study
-
Sugioka K., Hozumi T., Takemoto Y., Ujino K., Matsumura Y., Watanabe H., et al. Early recovery of impaired coronary flow reserve by carvedilol therapy in patients with idiopathic dilated cardiomyopathy: a serial transthoracic Doppler echocardiographic study. J Am Coll Cardiol 45 (2005) 318-319
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 318-319
-
-
Sugioka, K.1
Hozumi, T.2
Takemoto, Y.3
Ujino, K.4
Matsumura, Y.5
Watanabe, H.6
-
16
-
-
0028882611
-
Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles: demonstration and potential mechanisms
-
Porter T.R., and Xie F. Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles: demonstration and potential mechanisms. Circulation 92 (1995) 2391-2395
-
(1995)
Circulation
, vol.92
, pp. 2391-2395
-
-
Porter, T.R.1
Xie, F.2
-
17
-
-
0037192118
-
Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the cardiac imaging committee of the council on clinical cardiology of the American Heart Association
-
Cerqueira M.D., Weissman N.J., Dilsizian V., Jacobs A.K., Kaul S., Laskey W.K., et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the cardiac imaging committee of the council on clinical cardiology of the American Heart Association. Circulation 105 (2002) 539-542
-
(2002)
Circulation
, vol.105
, pp. 539-542
-
-
Cerqueira, M.D.1
Weissman, N.J.2
Dilsizian, V.3
Jacobs, A.K.4
Kaul, S.5
Laskey, W.K.6
-
18
-
-
13844297656
-
Comparison of low-mechanical index pulse sequence schemes for detecting myocardial perfusion abnormalities during vasodilator stress echocardiography
-
Tsutsui J.M., Xie F., McGrain A.C., Mahrous H., Hankins J., O'leary E.L., et al. Comparison of low-mechanical index pulse sequence schemes for detecting myocardial perfusion abnormalities during vasodilator stress echocardiography. Am J Cardiol 95 (2005) 565-570
-
(2005)
Am J Cardiol
, vol.95
, pp. 565-570
-
-
Tsutsui, J.M.1
Xie, F.2
McGrain, A.C.3
Mahrous, H.4
Hankins, J.5
O'leary, E.L.6
-
19
-
-
0032501992
-
Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
-
Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., and Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 97 (1998) 473-483
-
(1998)
Circulation
, vol.97
, pp. 473-483
-
-
Wei, K.1
Jayaweera, A.R.2
Firoozan, S.3
Linka, A.4
Skyba, D.M.5
Kaul, S.6
-
20
-
-
0037417849
-
Identification of hibernating myocardium with quantitative intravenous myocardial contrast echocardiography: comparison with dobutamine echocardiography and thallium-201 scintigraphy
-
Shimoni S., Frangogiannis N.G., Aggeli C.J., Shan K., Verani M.S., Quinones M.A., et al. Identification of hibernating myocardium with quantitative intravenous myocardial contrast echocardiography: comparison with dobutamine echocardiography and thallium-201 scintigraphy. Circulation 107 (2003) 538-544
-
(2003)
Circulation
, vol.107
, pp. 538-544
-
-
Shimoni, S.1
Frangogiannis, N.G.2
Aggeli, C.J.3
Shan, K.4
Verani, M.S.5
Quinones, M.A.6
-
21
-
-
0036829463
-
Measurement of coronary flow reserve in the anterior and posterior descending coronary arteries by transthoracic Doppler ultrasound
-
Voci P., Pizzuto F., Mariano E., Puddu P.E., Chiavari P.A., and Romeo F. Measurement of coronary flow reserve in the anterior and posterior descending coronary arteries by transthoracic Doppler ultrasound. Am J Cardiol 90 (2002) 988-991
-
(2002)
Am J Cardiol
, vol.90
, pp. 988-991
-
-
Voci, P.1
Pizzuto, F.2
Mariano, E.3
Puddu, P.E.4
Chiavari, P.A.5
Romeo, F.6
-
22
-
-
0036631547
-
Transthoracic echocardiographic visualization of coronary artery blood flow and assessment of coronary flow reserve in the right coronary artery: a first report of 3 patients
-
Tries H.P., Lambertz H., and Lethen H. Transthoracic echocardiographic visualization of coronary artery blood flow and assessment of coronary flow reserve in the right coronary artery: a first report of 3 patients. J Am Soc Echocardiogr 15 (2002) 739-742
-
(2002)
J Am Soc Echocardiogr
, vol.15
, pp. 739-742
-
-
Tries, H.P.1
Lambertz, H.2
Lethen, H.3
-
23
-
-
24944576201
-
Noninvasive diagnosis of coronary artery disease in patients with diabetes by dobutamine stress real-time myocardial contrast perfusion imaging
-
Elhendy A., Tsutsui J.M., O'leary E.L., Xie F., McGrain A.C., and Porter T.R. Noninvasive diagnosis of coronary artery disease in patients with diabetes by dobutamine stress real-time myocardial contrast perfusion imaging. Diabetes Care 28 (2005) 1662-1667
-
(2005)
Diabetes Care
, vol.28
, pp. 1662-1667
-
-
Elhendy, A.1
Tsutsui, J.M.2
O'leary, E.L.3
Xie, F.4
McGrain, A.C.5
Porter, T.R.6
-
24
-
-
0030811703
-
Coronary and myocardial blood volumes: noninvasive tools to assess the coronary microcirculation?
-
Kaul S., and Jayaweera A.R. Coronary and myocardial blood volumes: noninvasive tools to assess the coronary microcirculation?. Circulation 96 (1997) 719-724
-
(1997)
Circulation
, vol.96
, pp. 719-724
-
-
Kaul, S.1
Jayaweera, A.R.2
-
25
-
-
0032127747
-
Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?
-
Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., and Kaul S. Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?. J Am Coll Cardiol 32 (1998) 252-260
-
(1998)
J Am Coll Cardiol
, vol.32
, pp. 252-260
-
-
Wei, K.1
Jayaweera, A.R.2
Firoozan, S.3
Linka, A.4
Skyba, D.M.5
Kaul, S.6
-
26
-
-
0033373582
-
Role of capillaries in determining CBF reserve: new insights using myocardial contrast echocardiography
-
Jayaweera A.R., Wei K., Coggins M., Bin J.P., Goodman C., and Kaul S. Role of capillaries in determining CBF reserve: new insights using myocardial contrast echocardiography. Am J Physiol 277 (1999) H2363-H2372
-
(1999)
Am J Physiol
, vol.277
-
-
Jayaweera, A.R.1
Wei, K.2
Coggins, M.3
Bin, J.P.4
Goodman, C.5
Kaul, S.6
-
27
-
-
0242551299
-
Direct effects of dobutamine on the coronary microcirculation: comparison with adenosine using myocardial contrast echocardiography
-
Bin J.P., Le D.E., Jayaweera A.R., Coggins M.P., Wei K., and Kaul S. Direct effects of dobutamine on the coronary microcirculation: comparison with adenosine using myocardial contrast echocardiography. J Am Soc Echocardiogr 16 (2003) 871-879
-
(2003)
J Am Soc Echocardiogr
, vol.16
, pp. 871-879
-
-
Bin, J.P.1
Le, D.E.2
Jayaweera, A.R.3
Coggins, M.P.4
Wei, K.5
Kaul, S.6
-
28
-
-
0027787849
-
Perceptual organization and the judgment of brightness
-
Adelson E.H. Perceptual organization and the judgment of brightness. Science 262 (1993) 2042-2044
-
(1993)
Science
, vol.262
, pp. 2042-2044
-
-
Adelson, E.H.1
-
29
-
-
0018662919
-
Coronary artery narrowing in coronary heart disease: comparison of cineangiographic and necropsy findings
-
Arnett E.N., Isner J.M., Redwood D.R., Kent K.M., Baker W.P., Ackerstein H., et al. Coronary artery narrowing in coronary heart disease: comparison of cineangiographic and necropsy findings. Ann Intern Med 91 (1979) 350-356
-
(1979)
Ann Intern Med
, vol.91
, pp. 350-356
-
-
Arnett, E.N.1
Isner, J.M.2
Redwood, D.R.3
Kent, K.M.4
Baker, W.P.5
Ackerstein, H.6
-
30
-
-
0025785630
-
Intravenous adenosine: continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease
-
Kern M.J., Deligonul U., Tatineni S., Serota H., Aguirre F., and Hilton T.C. Intravenous adenosine: continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease. J Am Coll Cardiol 18 (1991) 718-729
-
(1991)
J Am Coll Cardiol
, vol.18
, pp. 718-729
-
-
Kern, M.J.1
Deligonul, U.2
Tatineni, S.3
Serota, H.4
Aguirre, F.5
Hilton, T.C.6
|