메뉴 건너뛰기




Volumn 35, Issue 6, 2007, Pages 1623-1624

High-frequency oscillation: How high should we go?

Author keywords

Acute respiratory distress syndrome; High frequency oscillation; Mechanical ventilation; Tidal volume

Indexed keywords

ACUTE LUNG INJURY; ARTIFICIAL VENTILATION; EDITORIAL; HIGH FREQUENCY OSCILLATION; INTENSIVE CARE UNIT; MORTALITY; PATIENT POSITIONING; PRIORITY JOURNAL; TIDAL VOLUME; TREATMENT FAILURE;

EID: 34249287375     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.CCM.0000267655.07864.26     Document Type: Editorial
Times cited : (5)

References (15)
  • 1
    • 0343893748 scopus 로고    scopus 로고
    • The Acute Respiratory Distress Syndrome Network: Ventilation with lower tidal as compared with traditional tidal for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 2000; 342:1301-1308
    • The Acute Respiratory Distress Syndrome Network: Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 2000; 342:1301-1308
  • 2
    • 0037464733 scopus 로고    scopus 로고
    • Ventilator-associated lung injury
    • Pinhu L, Whitehead T, Evans T, et al: Ventilator-associated lung injury. Lancet 2003; 361:332-340
    • (2003) Lancet , vol.361 , pp. 332-340
    • Pinhu, L.1    Whitehead, T.2    Evans, T.3
  • 3
    • 29844445334 scopus 로고    scopus 로고
    • Ventilator-induced lung injury: From the bench to the bedside
    • Tremblay LN, Slutsky AS: Ventilator-induced lung injury: From the bench to the bedside. Intensive Care Med 2006; 32:24-33
    • (2006) Intensive Care Med , vol.32 , pp. 24-33
    • Tremblay, L.N.1    Slutsky, A.S.2
  • 4
    • 3242679235 scopus 로고    scopus 로고
    • Mechanical ventilation with higher versus lower positive end-expiratory pressures in patients with acute lung injury and the acute respiratory distress syndrome
    • The National Heart Lung and Blood Institute ARDS Clinical Trials Network
    • The National Heart Lung and Blood Institute ARDS Clinical Trials Network: Mechanical ventilation with higher versus lower positive end-expiratory pressures in patients with acute lung injury and the acute respiratory distress syndrome. N Engl J Med 2004; 351: 327-336
    • (2004) N Engl J Med , vol.351 , pp. 327-336
  • 5
    • 0030967622 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation for adult respiratory distress syndrome - A pilot study
    • Fort P, Farmer C, Westerman J, et al: High-frequency oscillatory ventilation for adult respiratory distress syndrome - A pilot study. Crit Care Med 1997; 25:937-947
    • (1997) Crit Care Med , vol.25 , pp. 937-947
    • Fort, P.1    Farmer, C.2    Westerman, J.3
  • 6
    • 4143078162 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation in adults: The Toronto experience
    • Mehta S, Granton J, MacDonald RJ, et al: High-frequency oscillatory ventilation in adults: The Toronto experience. Chest 2004; 126:518-527
    • (2004) Chest , vol.126 , pp. 518-527
    • Mehta, S.1    Granton, J.2    MacDonald, R.J.3
  • 7
    • 14944341780 scopus 로고    scopus 로고
    • Combining high-frequency oscillatory ventilation and recruitment maneuvers in adults with early acute respiratory distress syndrome: The Treatment with Oscillation and an Open Lung Strategy (TOOLS) trial pilot study
    • Ferguson ND, Chiche JD, Kacmarek RM, et al: Combining high-frequency oscillatory ventilation and recruitment maneuvers in adults with early acute respiratory distress syndrome: The Treatment with Oscillation and an Open Lung Strategy (TOOLS) trial pilot study. Crit Care Med 2005; 33:479-486
    • (2005) Crit Care Med , vol.33 , pp. 479-486
    • Ferguson, N.D.1    Chiche, J.D.2    Kacmarek, R.M.3
  • 8
    • 0037106260 scopus 로고    scopus 로고
    • High frequency oscillatory ventilation for acute respiratory distress syndrome: A randomized controlled trial
    • Derdak S, Mehta S, Stewart TE, et al: High frequency oscillatory ventilation for acute respiratory distress syndrome: A randomized controlled trial. Am J Respir Crit Care Med 2002; 166:801-808
    • (2002) Am J Respir Crit Care Med , vol.166 , pp. 801-808
    • Derdak, S.1    Mehta, S.2    Stewart, T.E.3
  • 9
    • 23744490671 scopus 로고    scopus 로고
    • High frequency oscillatory ventilation compared with conventional mechanical ventilation in adult respiratory distress syndrome: A randomized controlled trial
    • Bollen CW, van Well GT, Sherry T, et al: High frequency oscillatory ventilation compared with conventional mechanical ventilation in adult respiratory distress syndrome: A randomized controlled trial. Crit Care 2005; 9:R430-R439
    • (2005) Crit Care , vol.9
    • Bollen, C.W.1    van Well, G.T.2    Sherry, T.3
  • 10
    • 0019786969 scopus 로고
    • Effects of frequency, tidal volume, and lung volume on CO2 elimination in dogs by high frequency (2-30 Hz), low tidal volume ventilation
    • Slutsky AS, Kamm RD, Rossing TH, et al: Effects of frequency, tidal volume, and lung volume on CO2 elimination in dogs by high frequency (2-30 Hz), low tidal volume ventilation. J Clin Invest 1981; 68:1475-1484
    • (1981) J Clin Invest , vol.68 , pp. 1475-1484
    • Slutsky, A.S.1    Kamm, R.D.2    Rossing, T.H.3
  • 11
    • 0037250751 scopus 로고    scopus 로고
    • Determinants of tidal volume during high-frequency oscillation
    • Sedeek KA, Takeuchi M, Suchodolski K, et al: Determinants of tidal volume during high-frequency oscillation. Crit Care Med 2003; 31:227-231
    • (2003) Crit Care Med , vol.31 , pp. 227-231
    • Sedeek, K.A.1    Takeuchi, M.2    Suchodolski, K.3
  • 12
    • 34249326214 scopus 로고    scopus 로고
    • Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome
    • Hager DN, Fessler HE, Kaczka DW, et al: Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome. Crit Care Med 2007; 35:1522-1529
    • (2007) Crit Care Med , vol.35 , pp. 1522-1529
    • Hager, D.N.1    Fessler, H.E.2    Kaczka, D.W.3
  • 13
    • 33644605458 scopus 로고    scopus 로고
    • Four methods of measuring tidal volume during high-frequency oscillatory ventilation
    • Hager DN, Fuld M, Kaczka DW, et al: Four methods of measuring tidal volume during high-frequency oscillatory ventilation. Crit Care Med 2006; 34:751-757
    • (2006) Crit Care Med , vol.34 , pp. 751-757
    • Hager, D.N.1    Fuld, M.2    Kaczka, D.W.3
  • 14
    • 0037106498 scopus 로고    scopus 로고
    • The incremental application of lung-protective high-frequency oscillatory ventilation
    • Froese AB: The incremental application of lung-protective high-frequency oscillatory ventilation. Am J Respir Crit Care Med 2002; 166:786-787
    • (2002) Am J Respir Crit Care Med , vol.166 , pp. 786-787
    • Froese, A.B.1
  • 15
    • 0037194696 scopus 로고    scopus 로고
    • Ventilation with small tidal volumes
    • Slutsky AS, Drazen JM: Ventilation with small tidal volumes. N Engl J Med 2002; 347:630-631
    • (2002) N Engl J Med , vol.347 , pp. 630-631
    • Slutsky, A.S.1    Drazen, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.