메뉴 건너뛰기




Volumn 6, Issue , 2005, Pages 3450-3459

AP1000 best estimate large break loca analysis performed with the westinghouse automated statistical treatment of uncertainty methop (astrum)

Author keywords

[No Author keywords available]

Indexed keywords

ADVANCED PASSIVE PLANT; COMPUTER CODES; LOCAL MAXIMUM OXIDATION (LMO); THERMAL POWER;

EID: 34249103353     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (17)
  • 1
    • 34249035453 scopus 로고    scopus 로고
    • Bajorek, S. M., et al., 1998, Code Qualification Document for Best Estimate LOCA Analysis, Technical Report WCAP-12945-NP-A, 1, Revision 2, and 2 through 5, Revision 1, Westinghouse Electric Company, Pittsburgh, PA.
    • Bajorek, S. M., et al., 1998, "Code Qualification Document for Best Estimate LOCA Analysis," Technical Report WCAP-12945-NP-A, Volume 1, Revision 2, and Volumes 2 through 5, Revision 1, Westinghouse Electric Company, Pittsburgh, PA.
  • 3
    • 84933180360 scopus 로고    scopus 로고
    • Assessment of the Emergency Core Cooling System (ECCS) Performance for Current and Advanced Plant Designs Using WCOBRA/TRAC
    • Frepoli, C., Nissley, M., Ohkawa, K., 2003, "Assessment of the Emergency Core Cooling System (ECCS) Performance for Current and Advanced Plant Designs Using WCOBRA/TRAC", Proceedings of ICAPP'03
    • (2003) Proceedings of ICAPP'03
    • Frepoli, C.1    Nissley, M.2    Ohkawa, K.3
  • 5
    • 10644292764 scopus 로고    scopus 로고
    • GRS Analyses for CSNI Uncertainty Methods Study (UMS)
    • NEA/CSNI/R(97)35, 1, June 1998
    • Glaeser, H., Hofer, E., Kloos, M., and Skorek, T., 1998, "GRS Analyses for CSNI Uncertainty Methods Study (UMS)," in CSNI Report NEA/CSNI/R(97)35, Volume 1, June 1998.
    • (1998) in CSNI Report
    • Glaeser, H.1    Hofer, E.2    Kloos, M.3    Skorek, T.4
  • 6
    • 34249075710 scopus 로고    scopus 로고
    • Glaeser, H., 2000, Uncertainty Evaluation of Thermal-Hydraulic Code Results, Proc. Int. Mtg. on Best-Estimate Methods in Nucl. Installation Safety Analysis (BE-2000) Washington D.C., November 2000.
    • Glaeser, H., 2000, "Uncertainty Evaluation of Thermal-Hydraulic Code Results," Proc. Int. Mtg. on "Best-Estimate" Methods in Nucl. Installation Safety Analysis (BE-2000) Washington D.C., November 2000.
  • 9
    • 10644233900 scopus 로고    scopus 로고
    • Comparison of Realistic Large Break LOCA Analyses of a 3-Loop Westinghouse Plant Using Response Surface and Statistical Sampling Techniques. Proceedings of ICONE-12
    • April 25-29, Arlington, Virginia Washington D.C, U.S.A
    • Muftuoglu, K., Ohkawa, K., Frepoli, C., Nissley, M.E., 2004. Comparison of Realistic Large Break LOCA Analyses of a 3-Loop Westinghouse Plant Using Response Surface and Statistical Sampling Techniques. Proceedings of ICONE-12, International Conference on Nuclear Engineering. April 25-29, 2004, Arlington, Virginia (Washington D.C.), U.S.A.
    • (2004) International Conference on Nuclear Engineering
    • Muftuoglu, K.1    Ohkawa, K.2    Frepoli, C.3    Nissley, M.E.4
  • 15
    • 0032203387 scopus 로고    scopus 로고
    • Application of code scaling applicability and uncertainty methodology to the large break loss of coolant
    • Young, M. Y., Bajorek, S. M., Nissley, M. E., and Hochreiter, L. E., 1998, "Application of code scaling applicability and uncertainty methodology to the large break loss of coolant," Nuclear Engineering and Design 186 (1998) 39-52.
    • (1998) Nuclear Engineering and Design , vol.186 , pp. 39-52
    • Young, M.Y.1    Bajorek, S.M.2    Nissley, M.E.3    Hochreiter, L.E.4
  • 17
    • 0002765765 scopus 로고
    • Determination of Sample Sizes for Setting Tolerance Limits
    • Wilks, S. S., 1941, "Determination of Sample Sizes for Setting Tolerance Limits," The Annals of Mathematical Statistics, Vol.12, pp. 91-96.
    • (1941) The Annals of Mathematical Statistics , vol.12 , pp. 91-96
    • Wilks, S.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.