메뉴 건너뛰기




Volumn 54, Issue 1, 2007, Pages 1-7

Compensation for the effect of soft tissue artefact on humeral axial rotation angle

Author keywords

Carrying angle; Humeral axial rotation angle; Movement analysis; Soft tissue artefact

Indexed keywords

ADULT; ALGORITHM; ARTICLE; ARTIFACT; BIOMECHANICS; ELBOW; FEMALE; HUMAN; HUMERUS; JOINT CHARACTERISTICS AND FUNCTIONS; MALE; MOVEMENT (PHYSIOLOGY); PHYSIOLOGY; REGRESSION ANALYSIS; ROTATION; SHOULDER; SIGNAL PROCESSING; SKELETAL MUSCLE; VALIDATION STUDY;

EID: 34249064581     PISSN: 13428810     EISSN: 13428810     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (14)
  • 1
    • 0032893788 scopus 로고    scopus 로고
    • A marker-based measurement procedure for unconstrained wrist and elbow motions
    • Schmidt R, Disselhorst-Klug C, Silny J, et al. A marker-based measurement procedure for unconstrained wrist and elbow motions. J Biomech 1999;32:615-621.
    • (1999) J Biomech , vol.32 , pp. 615-621
    • Schmidt, R.1    Disselhorst-Klug, C.2    Silny, J.3
  • 2
    • 0034308382 scopus 로고    scopus 로고
    • Movement biomechanics goes upwards: From the leg to the arm
    • Rau G, Disselhorst-Klug C, Schmidt R. Movement biomechanics goes upwards: from the leg to the arm. J Biomech 2000;33:1207-1216.
    • (2000) J Biomech , vol.33 , pp. 1207-1216
    • Rau, G.1    Disselhorst-Klug, C.2    Schmidt, R.3
  • 3
    • 21744442284 scopus 로고    scopus 로고
    • Soft tissue artefact assessment in humeral axial rotation
    • Cutti AG, Paolini G, Troncossi M, et al. Soft tissue artefact assessment in humeral axial rotation. Gait Posture 2005;21:341-349.
    • (2005) Gait Posture , vol.21 , pp. 341-349
    • Cutti, A.G.1    Paolini, G.2    Troncossi, M.3
  • 4
    • 28944441430 scopus 로고    scopus 로고
    • In vivo validation of a new technique that compensates for soft tissue artefact in the upper-arm: Preliminary results
    • Cutti AG, Cappello A, Davalli A. In vivo validation of a new technique that compensates for soft tissue artefact in the upper-arm: Preliminary results. Clin Biomech 2006;21:S13-S19.
    • (2006) Clin Biomech , vol.21
    • Cutti, A.G.1    Cappello, A.2    Davalli, A.3
  • 5
    • 19644398653 scopus 로고    scopus 로고
    • Human movement analysis using stereophotogrammetry - Part 3. Soft tissue artifact assessment and compensation
    • Leardini A, Chiari L, Della Croce U, et al. Human movement analysis using stereophotogrammetry - Part 3. Soft tissue artifact assessment and compensation. Gait Posture 2005;21:212-225.
    • (2005) Gait Posture , vol.21 , pp. 212-225
    • Leardini, A.1    Chiari, L.2    Della Croce, U.3
  • 6
    • 0036345771 scopus 로고    scopus 로고
    • Evaluation of the global optimisation method within the upper limb kinematics analysis
    • Roux E, Bouilland S, Godillon-Maquinghen AP, et al. Evaluation of the global optimisation method within the upper limb kinematics analysis. J Biomech 2002;35:1279-1283.
    • (2002) J Biomech , vol.35 , pp. 1279-1283
    • Roux, E.1    Bouilland, S.2    Godillon-Maquinghen, A.P.3
  • 7
    • 0033081306 scopus 로고    scopus 로고
    • Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints
    • Lu TW, O'Connor JJ. Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. J Biomech 1999;32:129-134.
    • (1999) J Biomech , vol.32 , pp. 129-134
    • Lu, T.W.1    O'Connor, J.J.2
  • 8
    • 20144387878 scopus 로고    scopus 로고
    • ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion-Part II: Shoulder, elbow, wrist and hand
    • Wu G, van der Helm FC, Veeger HE, et al. ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion-Part II: shoulder, elbow, wrist and hand. J Biomech 2005;38:981-992.
    • (2005) J Biomech , vol.38 , pp. 981-992
    • Wu, G.1    van der Helm, F.C.2    Veeger, H.E.3
  • 9
    • 0034286993 scopus 로고    scopus 로고
    • Scapular kinematics: Effects of altering the Euler angle sequence of rotations
    • Karduna AR, McClure PW, Michener LA. Scapular kinematics: effects of altering the Euler angle sequence of rotations. J Biomech 2000;33:1063-1068.
    • (2000) J Biomech , vol.33 , pp. 1063-1068
    • Karduna, A.R.1    McClure, P.W.2    Michener, L.A.3
  • 10
    • 0037739822 scopus 로고    scopus 로고
    • The globe system: An unambiguous description of shoulder positions in daily life movements
    • Doorenbosch CA, Harlaar J, Veeger DJ. The globe system: an unambiguous description of shoulder positions in daily life movements. J Rehabil Res Dev 2003;40:147-156.
    • (2003) J Rehabil Res Dev , vol.40 , pp. 147-156
    • Doorenbosch, C.A.1    Harlaar, J.2    Veeger, D.J.3
  • 11
    • 0023920571 scopus 로고
    • Application of a magnetic tracking device to kinesiologic studies
    • An KN, Jacobsen MC, Berglund LJ, et al. Application of a magnetic tracking device to kinesiologic studies. J Biomech 1988;21:613-620.
    • (1988) J Biomech , vol.21 , pp. 613-620
    • An, K.N.1    Jacobsen, M.C.2    Berglund, L.J.3
  • 13
    • 0028510969 scopus 로고
    • A functional task analysis and motion simulation for the development of a powered upper-limb orthosis
    • Romilly DP, Anglin C, Gosine RG, et al. A functional task analysis and motion simulation for the development of a powered upper-limb orthosis. IEEE Trans Rehabil Eng 1994;2:119-129.
    • (1994) IEEE Trans Rehabil Eng , vol.2 , pp. 119-129
    • Romilly, D.P.1    Anglin, C.2    Gosine, R.G.3
  • 14
    • 34249107479 scopus 로고    scopus 로고
    • A definition of the axial rotation angle of the shoulder joint
    • in press
    • Masuda T, Ishida A, Cao L, et al. A definition of the axial rotation angle of the shoulder joint. J Electromyogr Kinesiol, in press.
    • J Electromyogr Kinesiol
    • Masuda, T.1    Ishida, A.2    Cao, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.