메뉴 건너뛰기




Volumn 18, Issue 6, 2007, Pages 612-616

Rapid ablation for atrial flutter by targeting maximum voltage - Factors associated with short ablation times

Author keywords

Atrial flutter; Cardiac anatomy; Catheter ablation; Clinical

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; FEMALE; HEART ATRIUM FLUTTER; HIGH TEMPERATURE; HUMAN; INDEPENDENT VARIABLE; MAJOR CLINICAL STUDY; MALE; MULTIVARIATE ANALYSIS; MULTIVARIATE LOGISTIC REGRESSION ANALYSIS; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RADIOFREQUENCY ABLATION; RISK; SINUS RHYTHM; STATISTICAL ANALYSIS; TECHNIQUE; TREATMENT DURATION;

EID: 34249043241     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2007.00804.x     Document Type: Article
Times cited : (22)

References (17)
  • 1
    • 0034035737 scopus 로고    scopus 로고
    • Prospective randomized comparison of antiarrhythmic therapy versus first-line radiofrequency ablation in patients with atrial flutter
    • Natale A, Newby KH, Pisano E, Leonelli F, Fanelli R, Potenza D, Beheiry S, Tomassoni G : Prospective randomized comparison of antiarrhythmic therapy versus first-line radiofrequency ablation in patients with atrial flutter. J Am Coll Cardiol 2000 35 : 1898 1904.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1898-1904
    • Natale, A.1    Newby, K.H.2    Pisano, E.3    Leonelli, F.4    Fanelli, R.5    Potenza, D.6    Beheiry, S.7    Tomassoni, G.8
  • 2
    • 0030455627 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of atrial flutter. Further insights into the various types of isthmus block: Application to ablation during sinus rhythm
    • Poty H, Saoudi N, Nair M, Anselme F, Letac B : Radiofrequency catheter ablation of atrial flutter. Further insights into the various types of isthmus block: Application to ablation during sinus rhythm. Circulation 1996 94 : 3204 3213.
    • (1996) Circulation , vol.94 , pp. 3204-3213
    • Poty, H.1    Saoudi, N.2    Nair, M.3    Anselme, F.4    Letac, B.5
  • 7
    • 1942516919 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8- or 10-mm electrode catheters and a high-output radiofrequency energy generator: Results of a multicenter safety and efficacy study
    • Feld G, Wharton M, Plumb V, Daoud E, Friehling T, Epstein L : Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8- or 10-mm electrode catheters and a high-output radiofrequency energy generator: results of a multicenter safety and efficacy study. J Am Coll Cardiol 2004 43 : 1466 1472.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1466-1472
    • Feld, G.1    Wharton, M.2    Plumb, V.3    Daoud, E.4    Friehling, T.5    Epstein, L.6
  • 13
    • 33746033821 scopus 로고    scopus 로고
    • Cavotricuspid isthmus conduction is dependent on underlying anatomic bundle architecture: Observations using a maximum voltage-guided ablation technique
    • Redfearn DP, Skanes AC, Gula LJ, Krahn AD, Yee R, Klein GJ : Cavotricuspid isthmus conduction is dependent on underlying anatomic bundle architecture: Observations using a maximum voltage-guided ablation technique. J Cardiovasc Electrophysiol 2006 17 : 832 838.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 832-838
    • Redfearn, D.P.1    Skanes, A.C.2    Gula, L.J.3    Krahn, A.D.4    Yee, R.5    Klein, G.J.6
  • 15
    • 17044390848 scopus 로고    scopus 로고
    • The inferior right atrial isthmus: Further architectural insights for current and coming ablation technologies
    • Cabrera JA, Sanchez-Quintana D, Farre J, Rubio JM, Ho SY : The inferior right atrial isthmus: Further architectural insights for current and coming ablation technologies. J Cardiovasc Electrophysiol 2005 16 : 402 408.
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 402-408
    • Cabrera, J.A.1    Sanchez-Quintana, D.2    Farre, J.3    Rubio, J.M.4    Ho, S.Y.5
  • 16
    • 0033967233 scopus 로고    scopus 로고
    • Right atrial flutter isthmus revisited: Normal anatomy favors nonuniform anisotropic conduction
    • Waki K, Saito T, Becker AE : Right atrial flutter isthmus revisited: Normal anatomy favors nonuniform anisotropic conduction. J Cardiovasc Electrophysiol 2000 11 : 90 94.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 90-94
    • Waki, K.1    Saito, T.2    Becker, A.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.