Laboratory fume hoods: Influence of room air supply
-
Caplan KJ, Knutson GW (1978) Laboratory fume hoods: influence of room air supply. Am Ind Hyg Assoc J 43, 738-46.
-
(1978)
Am Ind Hyg Assoc J
, vol.43
, pp. 738-746
-
-
Caplan, K.J.1
Knutson, G.W.2
-
2
-
-
0025745948
-
Experimental and numerical investigations of the performance of fume cupboards
-
Durst F, Pereira JCF (1991) Experimental and numerical investigations of the performance of fume cupboards. Building and Environment 26, 153-64.
-
(1991)
Building and Environment
, vol.26
, pp. 153-164
-
-
Durst, F.1
Pereira, J.C.F.2
-
3
-
-
0032062872
-
Application of a tracer gas challenge with a human subject to investigate factor affecting the performance of laboratory fume hoods
-
Altemose BA, Flynn MR, Sprankle J (1998) Application of a tracer gas challenge with a human subject to investigate factor affecting the performance of laboratory fume hoods. Am Ind Hyg Assoc J 59, 321-7.
-
(1998)
Am Ind Hyg Assoc J
, vol.59
, pp. 321-327
-
-
Altemose, B.A.1
Flynn, M.R.2
Sprankle, J.3
-
4
-
-
0031658423
-
-
Joao RV, Party E, Gershey EL (1998) Fume hood performance: using a bypass in variable air systems. Appl Occup Environ Hyg 13, 708-12.
-
Joao RV, Party E, Gershey EL (1998) Fume hood performance: using a bypass in variable air volume systems. Appl Occup Environ Hyg 13, 708-12.
-
-
-
-
5
-
-
0033960107
-
Containment testing of laboratory hoods in the as-used condition
-
Greenley PL, Billings CE, DiBerardinis LJ, Edwards RW, Barkley WE (2000) Containment testing of laboratory hoods in the as-used condition. Appl Occup Environ Hyg 15, 209-16.
-
(2000)
Appl Occup Environ Hyg
, vol.15
, pp. 209-216
-
-
Greenley, P.L.1
Billings, C.E.2
DiBerardinis, L.J.3
Edwards, R.W.4
Barkley, W.E.5
-
6
-
-
0033975656
-
Required response time for variable air volume fume hood controller
-
Ekberg LE, Melin J (2000) Required response time for variable air volume fume hood controller. Ann Occup Hyg 44, 143-50.
-
(2000)
Ann Occup Hyg
, vol.44
, pp. 143-150
-
-
Ekberg, L.E.1
Melin, J.2
-
7
-
-
0024386055
-
A new method for quantitative, in-Use testing of laboratory fume hoods
-
Ivany RE, First MW, Diberardinis LJ (1989) A new method for quantitative, in-Use testing of laboratory fume hoods. Am Ind Hyg Assoc J 50, 275-80.
-
(1989)
Am Ind Hyg Assoc J
, vol.50
, pp. 275-280
-
-
Ivany, R.E.1
First, M.W.2
Diberardinis, L.J.3
-
8
-
-
0026684981
-
-
Fletcher B, Johnson AE (1992) Containment testing of fume cupboards-I. Methods. Ann Occup Hyg 36, 239-52.
-
Fletcher B, Johnson AE (1992) Containment testing of fume cupboards-I. Methods. Ann Occup Hyg 36, 239-52.
-
-
-
-
9
-
-
0026744272
-
Containment testing of fume cupboards-II. Test room measurements
-
Fletcher B, Johnson AE (1992) Containment testing of fume cupboards-II. Test room measurements. Ann Occup Hyg 36, 395-405.
-
(1992)
Ann Occup Hyg
, vol.36
, pp. 395-405
-
-
Fletcher, B.1
Johnson, A.E.2
-
10
-
-
0031660799
-
-
Volin CE, Joao RV, Reiman JS, Party E, Gershey EL (1998) Fume hood performance: face velocity variability inconsistent air systems. Appl Occup Environ Hyg 13, 656-62.
-
Volin CE, Joao RV, Reiman JS, Party E, Gershey EL (1998) Fume hood performance: face velocity variability inconsistent air volume systems. Appl Occup Environ Hyg 13, 656-62.
-
-
-
-
11
-
-
0031914333
-
Reducing employee exposure potential using the ANSI/ASHRAE 110 method of testing performance of laboratory fume hoods as a diagnostic tool
-
Maupins K, Hitchings DT (1998) Reducing employee exposure potential using the ANSI/ASHRAE 110 method of testing performance of laboratory fume hoods as a diagnostic tool. Am Ind Hyg Assoc J 59, 133-8.
-
(1998)
Am Ind Hyg Assoc J
, vol.59
, pp. 133-138
-
-
Maupins, K.1
Hitchings, D.T.2
-
12
-
-
34249016563
-
-
CEN (2003) Fume Cupboards - Parts 3: Type test methods, European Committee for Standardization (prEN 14175-3).
-
CEN (2003) Fume Cupboards - Parts 3: Type test methods, European Committee for Standardization (prEN 14175-3).
-
-
-
-
13
-
-
0004036006
-
-
Prentice Hall, Englewood Cliffs, New Jersey
-
Flagan RC, Seinfeld JH (1988) Fundamentals of Air Pollution Engineering, 290-357, Prentice Hall, Englewood Cliffs, New Jersey.
-
(1988)
Fundamentals of Air Pollution Engineering
, pp. 290-357
-
-
Flagan, R.C.1
Seinfeld, J.H.2
-
14
-
-
0026498250
-
The effect of contaminant source momentum on a worker's breathing zone concentration in a uniform freestream
-
Kim T, Flynn MR (1992) The effect of contaminant source momentum on a worker's breathing zone concentration in a uniform freestream. Am Ind Hyg Assoc J 53, 757-66.
-
(1992)
Am Ind Hyg Assoc J
, vol.53
, pp. 757-766
-
-
Kim, T.1
Flynn, M.R.2
-
15
-
-
0028955480
-
A review of wake effects on worker exposure
-
Flynn MR, Ljungqvist B (1995) A review of wake effects on worker exposure. Ann Occup Hyg 39, 211-21.
-
(1995)
Ann Occup Hyg
, vol.39
, pp. 211-221
-
-
Flynn, M.R.1
Ljungqvist, B.2
|