메뉴 건너뛰기




Volumn 31, Issue 3, 2007, Pages 345-349

Erratum: Percutaneous release of the trigger thumb: Is it safe, cheap and effective? (International Orthopaedics DOI: 10.1007/s00264-006-0180-1);Percutaneous release of the trigger thumb: Is it safe, cheap and effective?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FUNCTIONAL ASSESSMENT; HUMAN; LACERATION; LOCAL ANESTHESIA; MALE; NEEDLE; OUTCOME ASSESSMENT; PATIENT SAFETY; PERCUTANEOUS RELEASE; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; QUESTIONNAIRE; SCORING SYSTEM; STATISTICAL ANALYSIS; TECHNIQUE; TENDON INJURY; TENOSYNOVITIS; THERAPY EFFECT; THUMB INJURY; TREATMENT FAILURE; TREATMENT RESPONSE; TRIGGER THUMB;

EID: 34249026431     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00264-006-0294-5     Document Type: Erratum
Times cited : (45)

References (18)
  • 1
    • 0023938086 scopus 로고
    • A survey of 'trigger finger' in adults
    • 2
    • Bonnici AV, Spencer JD (1988) A survey of 'trigger finger' in adults. J Hand Surg (Br) 13(2):202-203
    • (1988) J Hand Surg (Br) , vol.13 , pp. 202-203
    • Bonnici, A.V.1    Spencer, J.D.2
  • 3
    • 0026602498 scopus 로고
    • Trigger fingers and thumb: When to splint, inject, or operate
    • 1
    • Patel MR, Bassini L (1992) Trigger fingers and thumb: when to splint, inject, or operate. J Hand Surg (Am) 17(1):110-113
    • (1992) J Hand Surg (Am) , vol.17 , pp. 110-113
    • Patel, M.R.1    Bassini, L.2
  • 4
    • 0020429472 scopus 로고
    • Office diagnosis and treatment of hand pain
    • 3
    • Urbaniak JR, Roth JH (1982) Office diagnosis and treatment of hand pain. Orthop Clin North Am 13(3):477-495
    • (1982) Orthop Clin North Am , vol.13 , pp. 477-495
    • Urbaniak, J.R.1    Roth, J.H.2
  • 5
    • 0024510530 scopus 로고
    • Transection of radial digital nerve of the thumb during trigger release
    • 2 Pt 1
    • Carrozzella J, Stern PJ, Von Kuster LC (1989) Transection of radial digital nerve of the thumb during trigger release. J Hand Surg (Am) 14(2 Pt 1):198-200
    • (1989) J Hand Surg (Am) , vol.14 , pp. 198-200
    • Carrozzella, J.1    Stern, P.J.2    Von Kuster, L.C.3
  • 6
    • 0000370924 scopus 로고
    • Surgical treatment of trigger-finger by a subcutaneous method
    • 4
    • Lorthioir J (1958) Surgical treatment of trigger-finger by a subcutaneous method. J Bone Joint Surg Am 40-A(4):793-795
    • (1958) J Bone Joint Surg Am , vol.40 A , pp. 793-795
    • Lorthioir, J.1
  • 7
    • 0034948943 scopus 로고    scopus 로고
    • Percutaneous release of trigger digits
    • 3
    • Blumberg N, Arbel R, Dekel S (2001) Percutaneous release of trigger digits. J Hand Surg [Br] 26(3):256-257
    • (2001) J Hand Surg [Br] , vol.26 , pp. 256-257
    • Blumberg, N.1    Arbel, R.2    Dekel, S.3
  • 8
    • 23744510246 scopus 로고    scopus 로고
    • Percutaneous trigger finger release: The 'lift-cut' technique
    • 6
    • Ragoowansi R, Acornley A, Khoo CT (2005). Percutaneous trigger finger release: the 'lift-cut' technique. Br J Plast Surg 58(6):817-821
    • (2005) Br J Plast Surg , vol.58 , pp. 817-821
    • Ragoowansi, R.1    Acornley, A.2    Khoo, C.T.3
  • 9
    • 4444326604 scopus 로고    scopus 로고
    • A1 pulley release of locked trigger digit by percutaneous technique
    • 5
    • Park MJ, Oh I, Ha KI (2004) A1 pulley release of locked trigger digit by percutaneous technique. J Hand Surg (Br) 29(5):502-505
    • (2004) J Hand Surg (Br]) , vol.29 , pp. 502-505
    • Park, M.J.1    Oh, I.2    Ha, K.I.3
  • 10
    • 0025006828 scopus 로고
    • Treatment of trigger finger by steroid injection
    • 5
    • Newport ML, Lane LB, Stuchin SA (1990) Treatment of trigger finger by steroid injection. J Hand Surg (Am) 15(5):748-750
    • (1990) J Hand Surg (Am) , vol.15 , pp. 748-750
    • Newport, M.L.1    Lane, L.B.2    Stuchin, S.A.3
  • 11
    • 29344460665 scopus 로고    scopus 로고
    • Steroid injections in the management of trigger fingers
    • 1
    • Nimigan AS, Ross DC, Gan BS (2006) Steroid injections in the management of trigger fingers. Am J Phys Med Rehabil 85(1):36-43
    • (2006) Am J Phys Med Rehabil , vol.85 , pp. 36-43
    • Nimigan, A.S.1    Ross, D.C.2    Gan, B.S.3
  • 13
    • 0345375503 scopus 로고    scopus 로고
    • Trigger thumb: Results of a prospective randomised study of percutaneous release with steroid injection versus steroid injection alone
    • 6
    • Maneerit J, Sriworakun C, Budhraja N, Nagavajara P (2003) Trigger thumb: results of a prospective randomised study of percutaneous release with steroid injection versus steroid injection alone. J Hand Surg (Br) 28(6):586-589
    • (2003) J Hand Surg (Br) , vol.28 , pp. 586-589
    • Maneerit, J.1    Sriworakun, C.2    Budhraja, N.3    Nagavajara, P.4
  • 14
    • 0026518731 scopus 로고
    • Percutaneous release of the trigger finger: An office procedure
    • 1
    • Eastwood DM, Gupta KJ, Johnson DP (1992) Percutaneous release of the trigger finger: an office procedure. J Hand Surg (Am) 17(1):114-117
    • (1992) J Hand Surg (Am) , vol.17 , pp. 114-117
    • Eastwood, D.M.1    Gupta, K.J.2    Johnson, D.P.3
  • 17
    • 0028916555 scopus 로고
    • Safety and efficacy of percutaneous trigger finger release
    • 2
    • Pope DF, Wolfe SW (1995) Safety and efficacy of percutaneous trigger finger release. J Hand Surg (Am) 20(2):280-283
    • (1995) J Hand Surg (Am) , vol.20 , pp. 280-283
    • Pope, D.F.1    Wolfe, S.W.2
  • 18
    • 0030994687 scopus 로고    scopus 로고
    • Percutaneous release of trigger digit with and without cortisone injection
    • 1
    • Patel MR, Moradia VJ (1997) Percutaneous release of trigger digit with and without cortisone injection. J Hand Surg (Am) 22(1):150-155
    • (1997) J Hand Surg (Am) , vol.22 , pp. 150-155
    • Patel, M.R.1    Moradia, V.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.