메뉴 건너뛰기




Volumn 32, Issue 12, 2007, Pages

Combined extraforaminal and intradiscal cement leakage following percutaneous vertebroplasty

Author keywords

Extraforaminal; Intradiscal; Percutaneous vertebroplasty; Polymethylmethacrylate

Indexed keywords

BONE CEMENT;

EID: 34249002242     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e31805c0b25     Document Type: Article
Times cited : (42)

References (24)
  • 1
    • 0043165850 scopus 로고
    • Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
    • Galibert P, Deramond H, Rosat P, et al. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 1987;33:166-8.
    • (1987) Neurochirurgie , vol.33 , pp. 166-168
    • Galibert, P.1    Deramond, H.2    Rosat, P.3
  • 2
    • 0029960122 scopus 로고    scopus 로고
    • Spinal metastases: Indications for and results of percutaneous injection of acrylic surgical cement
    • Weill A, Chiras J, Simon M, et al. Spinal metastases: indications for and results of percutaneous injection of acrylic surgical cement. Radiology 1996;199:241-7.
    • (1996) Radiology , vol.199 , pp. 241-247
    • Weill, A.1    Chiras, J.2    Simon, M.3
  • 3
    • 0029971187 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up
    • Cotten A, Dewatre F, Cortet B, et al. Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up. Radiology 1996;200:525-30.
    • (1996) Radiology , vol.200 , pp. 525-530
    • Cotten, A.1    Dewatre, F.2    Cortet, B.3
  • 4
    • 0032015176 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: State of the art
    • Cotten A, Boutry N, Cortet B, et al. Percutaneous vertebroplasty: state of the art. Radiographics 1998;18:311-20.
    • (1998) Radiographics , vol.18 , pp. 311-320
    • Cotten, A.1    Boutry, N.2    Cortet, B.3
  • 5
    • 0031778659 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty with polymethylmethacrylate: Technique, indications, and results
    • Deramond H, Depriester C, Galibert P, et al. Percutaneous vertebroplasty with polymethylmethacrylate: technique, indications, and results. Radiol Clin North Am 1998;36:533-46.
    • (1998) Radiol Clin North Am , vol.36 , pp. 533-546
    • Deramond, H.1    Depriester, C.2    Galibert, P.3
  • 6
    • 0032783733 scopus 로고    scopus 로고
    • Vertebroplasty: Clinical experience and follow-up results
    • Martin JB, Jean B, Sugiu K, et al. Vertebroplasty: clinical experience and follow-up results. Bone 1999;25(suppl):11-5.
    • (1999) Bone , vol.25 , Issue.SUPPL. , pp. 11-15
    • Martin, J.B.1    Jean, B.2    Sugiu, K.3
  • 7
    • 0034655411 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for pain relief and spinal stabilization
    • Barr JD, Barr MS, Lemley TJ, et al. Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine 2000;25:923-8.
    • (2000) Spine , vol.25 , pp. 923-928
    • Barr, J.D.1    Barr, M.S.2    Lemley, T.J.3
  • 8
    • 0032846650 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: An open prospective study
    • Cortet B, Cotten A, Boutry N, et al. Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: an open prospective study. J Rheumatol 1999;26:2222-8.
    • (1999) J Rheumatol , vol.26 , pp. 2222-2228
    • Cortet, B.1    Cotten, A.2    Boutry, N.3
  • 9
    • 0344718596 scopus 로고    scopus 로고
    • Acute osteoporotic vertebral collapse: Open study on percutaneous injection of acrylic surgical cement in 20 patients
    • Cyteval C, Baron-Sarrabere MP, Roux JO, et al. Acute osteoporotic vertebral collapse: open study on percutaneous injection of acrylic surgical cement in 20 patients. AJR Am J Roentgenol 1999;173:1685-90.
    • (1999) AJR Am J Roentgenol , vol.173 , pp. 1685-1690
    • Cyteval, C.1    Baron-Sarrabere, M.P.2    Roux, J.O.3
  • 10
    • 0034515155 scopus 로고    scopus 로고
    • Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty
    • Grados F, Depriester C, Cayrolle G, et al. Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty. Rheumatology 2000;39:1410-4.
    • (2000) Rheumatology , vol.39 , pp. 1410-1414
    • Grados, F.1    Depriester, C.2    Cayrolle, G.3
  • 11
    • 0033824345 scopus 로고    scopus 로고
    • Vertebroplasty in patients with severe vertebral compression fractures: A technical report
    • O'Brien JP, Sims JT, Evans AJ. Vertebroplasty in patients with severe vertebral compression fractures: a technical report. AJNR Am J Neuroradiol 2000;21:1555-8.
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1555-1558
    • O'Brien, J.P.1    Sims, J.T.2    Evans, A.J.3
  • 12
    • 0036211378 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for severe osteoporotic vertebral body compression fractures
    • Peh WCG, Gilula LA, Peck DD. Percutaneous vertebroplasty for severe osteoporotic vertebral body compression fractures. Radiology 2002;223:121-6.
    • (2002) Radiology , vol.223 , pp. 121-126
    • Peh, W.C.G.1    Gilula, L.A.2    Peck, D.D.3
  • 13
    • 0032897991 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty complicated by pulmonary embolus of acrylic cement
    • Perrin C, Jullien V, Padovani B, et al. Percutaneous vertebroplasty complicated by pulmonary embolus of acrylic cement. Rev Mal Respir 1999;16:215-7.
    • (1999) Rev Mal Respir , vol.16 , pp. 215-217
    • Perrin, C.1    Jullien, V.2    Padovani, B.3
  • 14
    • 0034918914 scopus 로고    scopus 로고
    • Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate: A case report
    • Harrington KD. Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate: a case report. J Bone Joint Surg Am 2001;83:1070-3.
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 1070-1073
    • Harrington, K.D.1
  • 15
    • 0033011007 scopus 로고    scopus 로고
    • Surgically controlled, transpedicular methylmethacrylate vertebroplasty with fluoroscopic guidance
    • Wenger M, Markwalder TM. Surgically controlled, transpedicular methylmethacrylate vertebroplasty with fluoroscopic guidance. Acta Neurochir (Wien) 1999;141:625-31.
    • (1999) Acta Neurochir (Wien) , vol.141 , pp. 625-631
    • Wenger, M.1    Markwalder, T.M.2
  • 16
    • 0035879089 scopus 로고    scopus 로고
    • New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures
    • Garfin SR, Yuan HA, Reiley MA. New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine 2001;26:1511-5.
    • (2001) Spine , vol.26 , pp. 1511-1515
    • Garfin, S.R.1    Yuan, H.A.2    Reiley, M.A.3
  • 17
    • 0036169233 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for osteoporotic compression fractures: Quantitative prospective evaluation of long-term outcomes
    • Zoarski GH, Snow P, Olan WJ, et al. Percutaneous vertebroplasty for osteoporotic compression fractures: quantitative prospective evaluation of long-term outcomes. J Vasc Interv Radiol 2002;13:139-48.
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 139-148
    • Zoarski, G.H.1    Snow, P.2    Olan, W.J.3
  • 18
    • 0036782669 scopus 로고    scopus 로고
    • Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report
    • Lee BJ, Lee SR, Yoo TY. Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: a case report. Spine 2002;27:E419-22.
    • (2002) Spine , vol.27
    • Lee, B.J.1    Lee, S.R.2    Yoo, T.Y.3
  • 19
    • 2442430895 scopus 로고    scopus 로고
    • Polymethylmethacrylate cement dislodgment following percutaneous vertebroplasty: A case report
    • Tsai TT, Chen WJ, Lai PL, et al. Polymethylmethacrylate cement dislodgment following percutaneous vertebroplasty: a case report. Spine 2003;28:E457-60.
    • (2003) Spine , vol.28
    • Tsai, T.T.1    Chen, W.J.2    Lai, P.L.3
  • 20
    • 33744785669 scopus 로고    scopus 로고
    • Intradural cement leakage: A devastatingly rare complication of vertebroplasty
    • Chen YJ, Tan TS, Chen WH, et al. Intradural cement leakage: a devastatingly rare complication of vertebroplasty. Spine 2006;31:E379-82.
    • (2006) Spine , vol.31
    • Chen, Y.J.1    Tan, T.S.2    Chen, W.H.3
  • 21
    • 18044402604 scopus 로고    scopus 로고
    • Root and spinal cord compression from methylmethacrylate vertebroplasty
    • Ratliff J, Nguyen T, Heiss J. Root and spinal cord compression from methylmethacrylate vertebroplasty. Spine 2001;26:E300-2.
    • (2001) Spine , vol.26
    • Ratliff, J.1    Nguyen, T.2    Heiss, J.3
  • 22
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral compression fractures: Technical aspects
    • Jensen ME, Avery JE, Mathis JM, et al. Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral compression fractures: technical aspects. AJNR Am J Neuroradiol 1997;18:1897-904.
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 1897-1904
    • Jensen, M.E.1    Avery, J.E.2    Mathis, J.M.3
  • 23
    • 33646573662 scopus 로고    scopus 로고
    • Intradiscal cement leak following percutaneous vertebroplasty
    • Mirovsky Y, Anekstein Y, Shalmon E, et al. Intradiscal cement leak following percutaneous vertebroplasty. Spine 2006;31:1120-4.
    • (2006) Spine , vol.31 , pp. 1120-1124
    • Mirovsky, Y.1    Anekstein, Y.2    Shalmon, E.3
  • 24
    • 1242339547 scopus 로고    scopus 로고
    • Vertebroplasty: Cement leakage into the disc increases the risk of new fracture of adjacent vertebral body
    • Lin EP, Ekholm S, Hiwatashi A, et al. Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body. AJNR Am J Neuroradiol 2004;25:175-80.
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 175-180
    • Lin, E.P.1    Ekholm, S.2    Hiwatashi, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.