메뉴 건너뛰기




Volumn 33, Issue 6, 2007, Pages 999-1004

Fitting behaviors of Fourier transform and Zernike polynomials

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; COMPARATIVE STUDY; CORNEA; ERROR; EVALUATION; EYE; FOURIER TRANSFORMATION; HUMAN; HYPERMETROPIA; KERATOMILEUSIS; MATHEMATICAL PHENOMENA; MYOPIA; OPTOMETRY; PRIORITY JOURNAL; PUPIL; RADIAL KERATOTOMY; STATISTICAL SIGNIFICANCE; TOPOGRAPHY; ZERNIKE POLYNOMIAL;

EID: 34248663499     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2007.03.017     Document Type: Article
Times cited : (24)

References (11)
  • 1
    • 0035112069 scopus 로고    scopus 로고
    • Clinical results of wavefront-guided laser in situ keratomileusis 3 months after surgery
    • Mrochen M., Kaemmerer M., and Seiler T. Clinical results of wavefront-guided laser in situ keratomileusis 3 months after surgery. J Cataract Refract Surg 27 (2001) 201-207
    • (2001) J Cataract Refract Surg , vol.27 , pp. 201-207
    • Mrochen, M.1    Kaemmerer, M.2    Seiler, T.3
  • 2
    • 0041856093 scopus 로고    scopus 로고
    • Clinical outcomes of wavefront-guided laser in situ keratomileusis: 6-month follow-up
    • Aizawa D., Shimizu K., Komatsu M., et al. Clinical outcomes of wavefront-guided laser in situ keratomileusis: 6-month follow-up. J Cataract Refract Surg 29 (2003) 1507-1513
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1507-1513
    • Aizawa, D.1    Shimizu, K.2    Komatsu, M.3
  • 3
    • 0345872191 scopus 로고    scopus 로고
    • Wavefront-guided laser in situ keratomileusis with the Bausch & Lomb Zyoptix system
    • Cosar C.B., Saltuk G., and Sener A.B. Wavefront-guided laser in situ keratomileusis with the Bausch & Lomb Zyoptix system. J Refract Surg 20 (2004) 35-39
    • (2004) J Refract Surg , vol.20 , pp. 35-39
    • Cosar, C.B.1    Saltuk, G.2    Sener, A.B.3
  • 4
    • 33747113980 scopus 로고
    • Beugungstheorie des Schneidenverfahrens und seiner verbesserten Form, der Phasenkontrastmethode. [Diffraction theory of the cut procedure and its improved form, the phase contrast method.]
    • Zernike F. Beugungstheorie des Schneidenverfahrens und seiner verbesserten Form, der Phasenkontrastmethode. [Diffraction theory of the cut procedure and its improved form, the phase contrast method.]. Physica 1 (1934) 689-704
    • (1934) Physica , vol.1 , pp. 689-704
    • Zernike, F.1
  • 5
    • 22544476497 scopus 로고    scopus 로고
    • Clinical comparison of 6 aberrometers. Part 1: technical specifications
    • Rozema J.J., Van Dyck D.E.M., and Tassignon M.-J. Clinical comparison of 6 aberrometers. Part 1: technical specifications. J Cataract Refract Surg 31 (2005) 1114-1127
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1114-1127
    • Rozema, J.J.1    Van Dyck, D.E.M.2    Tassignon, M.-J.3
  • 6
    • 0142169896 scopus 로고    scopus 로고
    • Zernike polynomial fitting fails to represent all visually significant corneal aberrations
    • Smolek M.K., and Klyce S.D. Zernike polynomial fitting fails to represent all visually significant corneal aberrations. Invest Ophthalmol Vis Sci 44 (2003) 4676-4681
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 4676-4681
    • Smolek, M.K.1    Klyce, S.D.2
  • 7
    • 4644252999 scopus 로고    scopus 로고
    • Advantages and disadvantages of the Zernike expansion for representing wave aberration of the normal and aberrated eye
    • Klyce S.D., Karon M.D., and Smolek M.K. Advantages and disadvantages of the Zernike expansion for representing wave aberration of the normal and aberrated eye. J Refract Surg 20 (2004) S537-S541
    • (2004) J Refract Surg , vol.20
    • Klyce, S.D.1    Karon, M.D.2    Smolek, M.K.3
  • 8
    • 32244435300 scopus 로고    scopus 로고
    • Goodness-of-prediction of Zernike polynomial fitting to corneal surfaces
    • Smolek M.K., and Klyce S.D. Goodness-of-prediction of Zernike polynomial fitting to corneal surfaces. J Cataract Refract Surg 31 (2005) 2350-2355
    • (2005) J Cataract Refract Surg , vol.31 , pp. 2350-2355
    • Smolek, M.K.1    Klyce, S.D.2
  • 9
    • 33644913155 scopus 로고    scopus 로고
    • Zernike aberration coefficients transformed to and from Fourier series coefficients for wavefront representation
    • Dai G.-M. Zernike aberration coefficients transformed to and from Fourier series coefficients for wavefront representation. Opt Lett 31 (2006) 501-503
    • (2006) Opt Lett , vol.31 , pp. 501-503
    • Dai, G.-M.1
  • 10
    • 0026065647 scopus 로고
    • Quantitative descriptors of corneal topography; a clinical study
    • Wilson S.E., and Klyce S.D. Quantitative descriptors of corneal topography; a clinical study. Arch Ophthalmol 109 (1991) 349-353
    • (1991) Arch Ophthalmol , vol.109 , pp. 349-353
    • Wilson, S.E.1    Klyce, S.D.2
  • 11
    • 22144437405 scopus 로고    scopus 로고
    • Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye
    • Carvalho L.A. Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye. Invest Ophthalmol Vis Sci 46 (2005) 1915-1926
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , pp. 1915-1926
    • Carvalho, L.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.