메뉴 건너뛰기




Volumn 259, Issue 2, 2007, Pages 955-965

The analysis of dosimetric thermoluminescent glow peak of CaF2:Mn after β-irradiation

Author keywords

CaF2:Mn; Dose response; Heating rate; Kinetic parameters; Thermoluminescence; TLD 400

Indexed keywords

DOSIMETRY; GAMMA RAYS; HEATING; KINETIC PARAMETERS; LOW TEMPERATURE EFFECTS; QUENCHING; THERMOLUMINESCENCE;

EID: 34248649883     PISSN: 0168583X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nimb.2007.02.104     Document Type: Article
Times cited : (30)

References (34)
  • 1
    • 0029792108 scopus 로고    scopus 로고
    • Environmental gamma dose measurements in Mexico City using TLD
    • Zarate-Morales A., and Buenfil A.E. Environmental gamma dose measurements in Mexico City using TLD. Health Phys. 71 3 (1996) 358
    • (1996) Health Phys. , vol.71 , Issue.3 , pp. 358
    • Zarate-Morales, A.1    Buenfil, A.E.2
  • 2
    • 0036889950 scopus 로고    scopus 로고
    • Monitoring environmental dose rate using Risø TL/OSL readers with built-in sources: recommendations for users
    • Kalchgruber R., Göksu H.Y., Hochhäuser E., and Wagner G.A. Monitoring environmental dose rate using Risø TL/OSL readers with built-in sources: recommendations for users. Radiat. Meas. 35 (2002) 585
    • (2002) Radiat. Meas. , vol.35 , pp. 585
    • Kalchgruber, R.1    Göksu, H.Y.2    Hochhäuser, E.3    Wagner, G.A.4
  • 8
    • 0002463453 scopus 로고
    • Recent developments in thermoluminescence kinetics
    • Levy P.W. Recent developments in thermoluminescence kinetics. Nucl. Tracks Radiat. Meas. 10 1-2 (1985) 21
    • (1985) Nucl. Tracks Radiat. Meas. , vol.10 , Issue.1-2 , pp. 21
    • Levy, P.W.1
  • 9
    • 0005242395 scopus 로고
    • 2:Mn thermoluminescence: a single glow peak not described by 1st or 2nd order kinetics
    • 2:Mn thermoluminescence: a single glow peak not described by 1st or 2nd order kinetics. Nucl. Tracks Radiat. Meas. 10 4-6 (1985) 557
    • (1985) Nucl. Tracks Radiat. Meas. , vol.10 , Issue.4-6 , pp. 557
    • Hornyak, W.F.1    Levy, P.W.2    Kierstead, J.A.3
  • 11
    • 0022898117 scopus 로고
    • The influence of TL glow curve evaluation algorithms on the reproducibility of dosemeter readings
    • Drazic G., Miklavzic U., and Mihelic M. The influence of TL glow curve evaluation algorithms on the reproducibility of dosemeter readings. Radiat. Prot. Dosim. 17 (1986) 343
    • (1986) Radiat. Prot. Dosim. , vol.17 , pp. 343
    • Drazic, G.1    Miklavzic, U.2    Mihelic, M.3
  • 15
    • 0029019898 scopus 로고
    • Computerised glow curve deconvolution: application to thermoluminescence dosimetry
    • Monograph
    • Horowitz Y.S., and Yossian D. Computerised glow curve deconvolution: application to thermoluminescence dosimetry. Monograph. Radiat. Prot. Dosim. 60 (1995) 1
    • (1995) Radiat. Prot. Dosim. , vol.60 , pp. 1
    • Horowitz, Y.S.1    Yossian, D.2
  • 20
    • 0033699735 scopus 로고    scopus 로고
    • Kinetic parameters of some tissue equivalent thermoluminescence materials
    • Kitis G., Furetta C., Prokić M., and Prokić V. Kinetic parameters of some tissue equivalent thermoluminescence materials. J. Phys. D: Appl. Phys. 33 (2000) 1252
    • (2000) J. Phys. D: Appl. Phys. , vol.33 , pp. 1252
    • Kitis, G.1    Furetta, C.2    Prokić, M.3    Prokić, V.4
  • 21
    • 0033924708 scopus 로고    scopus 로고
    • Kinetics parameters of CVD diamond by computerised glow-curve deconvolution (CGCD)
    • Furetta C., Kitis G., and Kuo C.H. Kinetics parameters of CVD diamond by computerised glow-curve deconvolution (CGCD). Nucl. Instr. and Meth. B 160 (2000) 65
    • (2000) Nucl. Instr. and Meth. B , vol.160 , pp. 65
    • Furetta, C.1    Kitis, G.2    Kuo, C.H.3
  • 22
    • 0013358463 scopus 로고
    • Computerized glow curve deconvolution applied to the analysis of the kinetics of peak 5 in LiF:Mg, Ti (TLD-100)
    • Yossian D., and Horowitz Y.S. Computerized glow curve deconvolution applied to the analysis of the kinetics of peak 5 in LiF:Mg, Ti (TLD-100). J. Phys. D. Appl. Phys. 28 (1995) 1495
    • (1995) J. Phys. D. Appl. Phys. , vol.28 , pp. 1495
    • Yossian, D.1    Horowitz, Y.S.2
  • 24
    • 84956131912 scopus 로고
    • Glow curves with general order kinetics
    • Chen R. Glow curves with general order kinetics. J. Electrochem. Soc. 116 (1969) 1254
    • (1969) J. Electrochem. Soc. , vol.116 , pp. 1254
    • Chen, R.1
  • 25
    • 0022109789 scopus 로고
    • Errors involved in the determination of activation energies in TL and TSDC by the initial rise method
    • Christodoulides C. Errors involved in the determination of activation energies in TL and TSDC by the initial rise method. J. Phys. D: Appl. Phys. 18 (1985) 1665
    • (1985) J. Phys. D: Appl. Phys. , vol.18 , pp. 1665
    • Christodoulides, C.1
  • 26
    • 0346393219 scopus 로고
    • On the determination of activation energy in thermoluminescence by the initial rise method
    • Singh T.S.C., Mazumdar P.S., and Gartia R.K. On the determination of activation energy in thermoluminescence by the initial rise method. J. Phys. D: Appl. Phys. 21 (1988) 1312
    • (1988) J. Phys. D: Appl. Phys. , vol.21 , pp. 1312
    • Singh, T.S.C.1    Mazumdar, P.S.2    Gartia, R.K.3
  • 27
    • 0343208585 scopus 로고
    • Thermal quenching of luminescence in six thermoluminescent dosimetry phosphors - II: quenching of thermoluminescence
    • Gorbics S.G., Nash A.E., and Attix F.H. Thermal quenching of luminescence in six thermoluminescent dosimetry phosphors - II: quenching of thermoluminescence. Int. J. Appl. Radiat. Isotopes 20 12 (1969) 843
    • (1969) Int. J. Appl. Radiat. Isotopes , vol.20 , Issue.12 , pp. 843
    • Gorbics, S.G.1    Nash, A.E.2    Attix, F.H.3
  • 30
    • 0037459353 scopus 로고    scopus 로고
    • The analysis of thermoluminescence glow peaks of unannealed synthetic quartz
    • Yazici A.N., and Mustafa T. The analysis of thermoluminescence glow peaks of unannealed synthetic quartz. J. Phys. D: Appl. Phys. 36 6 (2003) 620
    • (2003) J. Phys. D: Appl. Phys. , vol.36 , Issue.6 , pp. 620
    • Yazici, A.N.1    Mustafa, T.2
  • 31
    • 34248633511 scopus 로고    scopus 로고
    • 2: Mn(TLD-400) thermoluminescence dosimeters, in: 5th European Conference on Luminescent Detectors and Transformers of Ionizing Radiation; September 1-5, 2003, Prague.
  • 32
    • 0027324070 scopus 로고
    • An intercomparison of glow curve analysis computer programs: I. Synthetic glow curves
    • Bos A.J.J., Piters T.M., Gómez-Ros J.M., and Delgado A. An intercomparison of glow curve analysis computer programs: I. Synthetic glow curves. Radiat. Prot. Dosim. 47 (1993) 473
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 473
    • Bos, A.J.J.1    Piters, T.M.2    Gómez-Ros, J.M.3    Delgado, A.4
  • 33
    • 0000572932 scopus 로고
    • A formula for universal assessment of goodness-of-fit of gamma ray spectra
    • Misra S.K., and Eddy N.W. A formula for universal assessment of goodness-of-fit of gamma ray spectra. Nucl. Instr. and Meth. 166 (1979) 537
    • (1979) Nucl. Instr. and Meth. , vol.166 , pp. 537
    • Misra, S.K.1    Eddy, N.W.2
  • 34
    • 0029815488 scopus 로고    scopus 로고
    • A new look at the models of the superlinear dose dependence of thermoluminescence
    • Chen R., Fogel G., and Lee C.K. A new look at the models of the superlinear dose dependence of thermoluminescence. Radiat. Prot. Dosim. 65 (1996) 63
    • (1996) Radiat. Prot. Dosim. , vol.65 , pp. 63
    • Chen, R.1    Fogel, G.2    Lee, C.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.