메뉴 건너뛰기




Volumn 54, Issue 4, 2007, Pages 782-792

Cystic resolution: A performance metric for ultrasound imaging systems

Author keywords

[No Author keywords available]

Indexed keywords

ANALOG-TO-DIGITAL CONVERTERS; APODIZATION; COHERENT IMAGING SYSTEMS; ELECTRONIC NOISE; HANDHELD; MEDICAL ULTRASOUNDS; PERFORMANCE METRIC; SIGNAL-TO-NOISE RATIOS; SIMULATION EXAMPLES; ULTRASOUND IMAGING SYSTEMS; ULTRASOUND SCANNERS;

EID: 34248592528     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2007.311     Document Type: Article
Times cited : (49)

References (15)
  • 1
    • 64849097620 scopus 로고    scopus 로고
    • B. D. Steinberg, Principles of Aperture and Array System Design. New York: Wiley, 1976, pp. 40-52.
    • B. D. Steinberg, Principles of Aperture and Array System Design. New York: Wiley, 1976, pp. 40-52.
  • 2
    • 0029454474 scopus 로고
    • Towards a resolution metric for medical ultrasonic imaging
    • D. Vilkomerson, J. Greenleaf, and V. Dutt, "Towards a resolution metric for medical ultrasonic imaging," in Proc. IEEE Ultrason. Symp., 1995, pp. 1405-1410.
    • (1995) Proc. IEEE Ultrason. Symp , pp. 1405-1410
    • Vilkomerson, D.1    Greenleaf, J.2    Dutt, V.3
  • 3
    • 14744270383 scopus 로고    scopus 로고
    • Association of automated and human observer lesion detecting ability using phantoms
    • J. M. Kofler, M. J. Lindstrom, F. Kelcz, and E. M. Madsen, "Association of automated and human observer lesion detecting ability using phantoms," Ultrasound Med. Biol., vol. 3, pp. 351-359, 2005.
    • (2005) Ultrasound Med. Biol , vol.3 , pp. 351-359
    • Kofler, J.M.1    Lindstrom, M.J.2    Kelcz, F.3    Madsen, E.M.4
  • 4
    • 33847105035 scopus 로고    scopus 로고
    • Ultrasound imaging system performance assessment
    • presented at, San Diego, CA
    • K. F. Üstüner and G. L. Holley, "Ultrasound imaging system performance assessment," presented at 2003 AAPM Annual Meeting, 2003, San Diego, CA.
    • (2003) 2003 AAPM Annual Meeting
    • Üstüner, K.F.1    Holley, G.L.2
  • 8
    • 0019533519 scopus 로고
    • Some windows with very good sidelobe behavior
    • A. H. Nuttall, "Some windows with very good sidelobe behavior," IEEE Trans. Acoust. Speech Signal Processing, vol. 29, no. 1, pp. 84-91, 1981.
    • (1981) IEEE Trans. Acoust. Speech Signal Processing , vol.29 , Issue.1 , pp. 84-91
    • Nuttall, A.H.1
  • 9
    • 0026838720 scopus 로고
    • Calculation of pressure fields from arbitrarily shaped apodized and excited ultrasound transducers
    • J. A. Jensen and N. B. Svendsen, "Calculation of pressure fields from arbitrarily shaped apodized and excited ultrasound transducers," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 39, no. 2, pp. 262-267, 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.39 , Issue.2 , pp. 262-267
    • Jensen, J.A.1    Svendsen, N.B.2
  • 13
    • 0017851927 scopus 로고
    • On the use of windows for harmonic analysis with the discrete Fourier transform
    • F. J. Harris, "On the use of windows for harmonic analysis with the discrete Fourier transform," Proc. IEEE, vol. 66, no. 1, pp. 51-83, 1978.
    • (1978) Proc. IEEE , vol.66 , Issue.1 , pp. 51-83
    • Harris, F.J.1
  • 14
    • 80054750271 scopus 로고
    • Speech, and Signal Processing Society, Ed
    • Digital Signal Processing Committee of IEEE Acoustics, New York: IEEE Press, Program 5.2
    • Digital Signal Processing Committee of IEEE Acoustics, Speech, and Signal Processing Society, Ed. Programs for Digital Signal Processing. New York: IEEE Press, 1979, Program 5.2.
    • (1979) Programs for Digital Signal Processing


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.