Volumn 464, Issue 1-2, 2007, Pages 157-169

Mitigation of sensitisation effects in unstabilised 12%Cr ferritic stainless steel welds

Author keywords

12 Cr steel; Ferritic stainless steel; Sensitisation; Welding

Indexed keywords

CORROSION; FERRITIC STEEL; HEAT AFFECTED ZONE; WELDING;

EID: 34248582380     PISSN: 09215093     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.msea.2007.02.113     Document Type: Article
Times cited : (78)

References (19)
  • 1
    • 85161624800 scopus 로고
    • Peckner D., and Bernstein I.M. (Eds), McGraw-Hill Book Company
    • Demo J.J. In: Peckner D., and Bernstein I.M. (Eds). Handbook of Stainless Steels (1977), McGraw-Hill Book Company 5.1-5.40
    • (1977) Handbook of Stainless Steels
    • Demo, J.J.1
  • 2
    • 85161631266 scopus 로고    scopus 로고
    • Columbus Stainless-3CR12 Technical Manual, April 2001.
  • 7
    • 85161650216 scopus 로고    scopus 로고
    • M.L. Greef, M. Du Toit, The sensitisation of two 11-12% chromium type EN 1.4003 ferritic stainless steels during continuous cooling after welding, IIW Document No. IX-2182-05, 2005, pp. 1-11.
  • 8
    • 85161642484 scopus 로고    scopus 로고
    • T.G. Gooch, P. Woollin, A.G. Haynes, Microstructural development on welding low carbon 13% Cr martensitic steels, IIW Document No. IX-H-449-99, 1999, pp. 1-15.
  • 12
    • 85161708908 scopus 로고    scopus 로고
    • D.A.A. Smith, Tarboton J.N., Personal Communication, Columbus Stainless Pty Ltd., 2005.
  • 16
    • 0015205788 scopus 로고
    • Demo J.J. Corrosion 27 12 (1971) 531-544
    • (1971) Corrosion , vol.27 , Issue.12 , pp. 531-544
    • Demo, J.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.