메뉴 건너뛰기




Volumn 6429, Issue , 2007, Pages

Optical delay line using rotating rhombic prisms

Author keywords

Biomedical imaging; Delay line; Low coherence interferometry; Optical coherence tomography

Indexed keywords

MEDICAL IMAGING; OPTICAL TOMOGRAPHY; PRISMS; TISSUE;

EID: 34248579507     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.701047     Document Type: Conference Paper
Times cited : (18)

References (9)
  • 1
    • 0141705714 scopus 로고    scopus 로고
    • Reference optical delay scanning
    • B. E. Bouma and G. J. Tearney, eds, pp, Marcel Dekker, Inc, New-York
    • A. Rollins and J. A. Izatt, "Reference optical delay scanning," in Handbook of Optical Coherence Tomography, B. E. Bouma and G. J. Tearney, eds., pp. 99-123, Marcel Dekker, Inc., New-York, 2002.
    • (2002) Handbook of Optical Coherence Tomography , pp. 99-123
    • Rollins, A.1    Izatt, J.A.2
  • 2
    • 34248581428 scopus 로고    scopus 로고
    • Methods and apparatus for high speed longitudinal scanning in imaging systems,
    • U.S. Patent 6,191,862 Feb. 20
    • E. A. Swanson and C. Petersen, "Methods and apparatus for high speed longitudinal scanning in imaging systems," U.S. Patent 6,191,862 Feb. 20, 2001.
    • (2001)
    • Swanson, E.A.1    Petersen, C.2
  • 3
    • 0031164821 scopus 로고    scopus 로고
    • Rapid and scalable scans at 21 m/s in optical low-coherence reflectometry
    • J. Ballif, R. Gianotti, P. Chavanne, R. Walti, and R. P. Salathe, "Rapid and scalable scans at 21 m/s in optical low-coherence reflectometry," Optics Letters 22(11), pp. 757-759, 1997.
    • (1997) Optics Letters , vol.22 , Issue.11 , pp. 757-759
    • Ballif, J.1    Gianotti, R.2    Chavanne, P.3    Walti, R.4    Salathe, R.P.5
  • 4
    • 34248591105 scopus 로고    scopus 로고
    • Optical path length modulator,
    • U.S. Patent 6,243,191, June 5
    • A. F. Fercher, "Optical path length modulator," U.S. Patent 6,243,191, June 5, 2001a.
    • (2001)
    • Fercher, A.F.1
  • 5
    • 0038826198 scopus 로고    scopus 로고
    • Kilohertz scanning optical delay line employing a prism array
    • M. Lai, "Kilohertz scanning optical delay line employing a prism array," Applied Optics 40(34), pp. 6334-6336, 2001.
    • (2001) Applied Optics , vol.40 , Issue.34 , pp. 6334-6336
    • Lai, M.1
  • 6
    • 0038312802 scopus 로고    scopus 로고
    • Scanning delay line with a rotating-parallelogram prism for low-coherence interferometry
    • L. Giniunas, R. Danielius, and R. Karkockas, "Scanning delay line with a rotating-parallelogram prism for low-coherence interferometry," Applied Optics 38(34), pp. 7076-7079, 1999.
    • (1999) Applied Optics , vol.38 , Issue.34 , pp. 7076-7079
    • Giniunas, L.1    Danielius, R.2    Karkockas, R.3
  • 7
    • 0000950968 scopus 로고    scopus 로고
    • Rapid acquisition of in vivo biological images by use of optical coherence tomography
    • G. J. Tearney, B. E. Bouma, S. A. Boppart, B. Golubovic, E. A. Swanson, and J. G. Fujimoto, "Rapid acquisition of in vivo biological images by use of optical coherence tomography," Optics Letters 21(17), pp. 1408-1410, 1996.
    • (1996) Optics Letters , vol.21 , Issue.17 , pp. 1408-1410
    • Tearney, G.J.1    Bouma, B.E.2    Boppart, S.A.3    Golubovic, B.4    Swanson, E.A.5    Fujimoto, J.G.6
  • 9
    • 5244345537 scopus 로고    scopus 로고
    • High-speed phase- and group-delay scanning with a grating-based phase control delay line
    • G. J. Tearney, B. E. Bouma, and J. G. Fujimoto, "High-speed phase- and group-delay scanning with a grating-based phase control delay line," Optics Letters 22(23), pp. 1811-1813, 1997.
    • (1997) Optics Letters , vol.22 , Issue.23 , pp. 1811-1813
    • Tearney, G.J.1    Bouma, B.E.2    Fujimoto, J.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.