메뉴 건너뛰기




Volumn 5, Issue 1, 2007, Pages 289-292

Measurement of ratio error and phase displacement of DC tolerant current transformers

Author keywords

Current transformer; DC tolerance; Phase displacement; Ratio error

Indexed keywords

DC TRANSFORMERS; ELECTRIC MEASURING INSTRUMENTS; ERROR ANALYSIS; MEASUREMENT ERRORS; MECHANICAL PERMEABILITY;

EID: 34248579198     PISSN: 1546198X     EISSN: None     Source Type: Journal    
DOI: 10.1166/sl.2007.005     Document Type: Conference Paper
Times cited : (7)

References (5)
  • 2
    • 34248516726 scopus 로고    scopus 로고
    • Use of instrument current transformers in wider frequency range
    • Osaka
    • K. Draxler and R. Styblíková, Use of instrument current transformers in wider frequency range. Proc. of IMEKO XV World Congress, Osaka (1999), Vol. 6, pp. 113-117.
    • (1999) Proc. of IMEKO XV World Congress , vol.6 , pp. 113-117
    • Draxler, K.1    Styblíková, R.2
  • 3
    • 34248559065 scopus 로고    scopus 로고
    • Sources of additional errors of the instrument current transformer
    • Osaka
    • R. Styblíková and K. Draxler, Sources of additional errors of the instrument current transformer. Proc. of IMEKO XV World Congress, Osaka (1999), Vol. 6. pp. 1-5.
    • (1999) Proc. of IMEKO XV World Congress , vol.6 , pp. 1-5
    • Styblíková, R.1    Draxler, K.2
  • 4
    • 34248568542 scopus 로고    scopus 로고
    • AMH_.doc from www.vacuumschmelze.de, CT application note (2005).
    • AMH_.doc from www.vacuumschmelze.de, CT application note (2005).
  • 5
    • 34248535685 scopus 로고    scopus 로고
    • http://metering.oswell.com.cn,website of Oswell Metering.
    • http://metering.oswell.com.cn,website of Oswell Metering.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.