Evaluation of the sensitivity of USP prednisone tablets to dissolved gas in the dissolution medium using USP apparatus 2

Author keywords

[No Author keywords available]

Indexed keywords

ARGON; CARBON DIOXIDE; DEIONIZED WATER; DISSOLVED OXYGEN; HELIUM; NITROGEN; PREDNISONE;

EID: 34248576042     PISSN: 1521298X     EISSN: None     Source Type: Journal    
DOI: 10.14227/DT130306P15     Document Type: Article
Times cited : (18)

References (14)
  • 1
    • 0003428589 scopus 로고    scopus 로고
    • Guidance for Industry; U.S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, U.S. Government Printing Office: Washington, DC
    • Dissolution Testing of Immediate-Release Solid Oral Dosage Forms. Guidance for Industry; U. S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, U. S. Government Printing Office: Washington, DC, 1997.
    • (1997) Dissolution Testing of Immediate-Release Solid Oral Dosage Forms
  • 2
    • 0032923660 scopus 로고    scopus 로고
    • Typical variability in drug dissolution testing: Study with USP and FDA calibrator tablets and a marketed drug (glibenclamide) product
    • Qureshi, S. A.; McGilveray, I. J. Typical variability in drug dissolution testing: study with USP and FDA calibrator tablets and a marketed drug (glibenclamide) product. Eur. J. Pharm. Sci. 1999, 7, 249-258.
    • (1999) Eur. J. Pharm. Sci , vol.7 , pp. 249-258
    • Qureshi, S.A.1    McGilveray, I.J.2
  • 3
    • 0001262837 scopus 로고
    • Impact of different deaeration methods on the USP dissolution apparatus suitability test criteria
    • Qureshi, S. A.; McGilveray, I. J. Impact of different deaeration methods on the USP dissolution apparatus suitability test criteria. Pharm. Forum. 1994, 8565-8566.
    • (1994) Pharm. Forum , pp. 8565-8566
    • Qureshi, S.A.1    McGilveray, I.J.2
  • 4
    • 10544239130 scopus 로고
    • Dissolution calibrators used by the United States Pharmacopeia
    • Grady, L. T. Dissolution calibrators used by the United States Pharmacopeia. Pharm. Forum. 1994, 20, 8567-8570.
    • (1994) Pharm. Forum , vol.20 , pp. 8567-8570
    • Grady, L.T.1
  • 6
    • 84962073694 scopus 로고
    • USP dissolution calibrator tablets-is it time to reduce the amount of testing required to calibrate apparatus 1 and 2?
    • Lindauer, R. F. USP dissolution calibrator tablets-is it time to reduce the amount of testing required to calibrate apparatus 1 and 2? Pharm. Forum. 1995, 21, 1397-1402.
    • (1995) Pharm. Forum , vol.21 , pp. 1397-1402
    • Lindauer, R.F.1
  • 7
    • 84962094409 scopus 로고    scopus 로고
    • Measurement of dissolved oxygen as a determination of media equilibrium during dissolution testing
    • Curley, T.; Forsyth, R.; Sun, S.; Fliszar, K.; Colletto, M.; Martin, G. P. Measurement of dissolved oxygen as a determination of media equilibrium during dissolution testing. Dissolution Technol. 2004, 11 (4), 6-11.
    • (2004) Dissolution Technol , vol.11 , Issue.4 , pp. 6-11
    • Curley, T.1    Forsyth, R.2    Sun, S.3    Fliszar, K.4    Colletto, M.5    Martin, G.P.6
  • 8
    • 84962115598 scopus 로고    scopus 로고
    • Dissolved oxygen as a measure for de- and reaeration of aqueous media for dissolution testing
    • Diebold, S. M.; Dressman, J. B. Dissolved oxygen as a measure for de- and reaeration of aqueous media for dissolution testing. Dissolution Technol. 1998, 5 (3), 13-16.
    • (1998) Dissolution Technol , vol.5 , Issue.3 , pp. 13-16
    • Diebold, S.M.1    Dressman, J.B.2
  • 9
    • 1942498134 scopus 로고
    • Deaeration techniques for dissolution media
    • Rohrs, B. R.; Stelzer, D. J. Deaeration techniques for dissolution media. Dissolution Technol. 1995, 2 (2), 6-8.
    • (1995) Dissolution Technol , vol.2 , Issue.2 , pp. 6-8
    • Rohrs, B.R.1    Stelzer, D.J.2
  • 11
    • 33745900777 scopus 로고    scopus 로고
    • Effects of deaeration methods on dissolution testing in aqueous media: A study using a total dissolved gas pressure meter
    • Gao, Z.; Moore, T. W.; Doub, W. H.; Westenberger, B. J.; Buhse, L. F. Effects of deaeration methods on dissolution testing in aqueous media: A study using a total dissolved gas pressure meter. J. Pharm. Sci. 2006, 95, 1606-1613.
    • (2006) J. Pharm. Sci , vol.95 , pp. 1606-1613
    • Gao, Z.1    Moore, T.W.2    Doub, W.H.3    Westenberger, B.J.4    Buhse, L.F.5
  • 14
    • 84962077054 scopus 로고    scopus 로고
    • Dissolution testing: A fast, efficient procedure for degassing dissolution medium
    • Moore, T. W. Dissolution testing: a fast, efficient procedure for degassing dissolution medium. Dissolution Technol. 1996, 3 (2), 3-5.
    • (1996) Dissolution Technol , vol.3 , Issue.2 , pp. 3-5
    • Moore, T.W.1