메뉴 건너뛰기




Volumn 6429, Issue , 2007, Pages

Automatic retinal blood vessel parameter calculation in spectral domain optical coherence tomography

Author keywords

Angiogram; Blood flow; Blood vessels; Optical coherence tomography; Retina

Indexed keywords

BLOOD FLOW; BLOOD FLOW VELOCITY; DOPPLER INFORMATION; OPTIC DISC;

EID: 34248574639     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.702513     Document Type: Conference Paper
Times cited : (5)

References (7)
  • 2
    • 0037088454 scopus 로고    scopus 로고
    • Imaging and quantifying transverse flow velocity with the Doppler bandwidth in a phase-resolved functional optical coherence tomography
    • H. Ren, K. M. Brecke, Z. Ding, Y. Zhao, J. S. Nelson, and Z. Chen, "Imaging and quantifying transverse flow velocity with the Doppler bandwidth in a phase-resolved functional optical coherence tomography," Opt. Lett. 27, 409-411 (2002).
    • (2002) Opt. Lett , vol.27 , pp. 409-411
    • Ren, H.1    Brecke, K.M.2    Ding, Z.3    Zhao, Y.4    Nelson, J.S.5    Chen, Z.6
  • 3
    • 0001265874 scopus 로고    scopus 로고
    • High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography
    • T. G. van Leeuwen, M. D. Kulkarni, S. Yazdanfar, A. M. Rollins, and J. A. Izatt, "High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography," Opt. Lett. 24,1584-1586 (1999).
    • (1999) Opt. Lett , vol.24 , pp. 1584-1586
    • van Leeuwen, T.G.1    Kulkarni, M.D.2    Yazdanfar, S.3    Rollins, A.M.4    Izatt, J.A.5
  • 4
    • 0029851416 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography
    • Schuman JS, Pedut-Kloizman T, Hertzmark E, et al. "Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography" Ophthalmology 1996;103:1889-98.
    • (1996) Ophthalmology , vol.103 , pp. 1889-1898
    • Schuman, J.S.1    Pedut-Kloizman, T.2    Hertzmark, E.3
  • 5
    • 0033653784 scopus 로고    scopus 로고
    • Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography
    • Eytan Z. Blumenthal, Julia M. Williams, Robert N. Weinreb et al. "Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography", Ophthalmology 2000;107:2278-2282.
    • (2000) Ophthalmology , vol.107 , pp. 2278-2282
    • Blumenthal, E.Z.1    Williams, J.M.2    Weinreb, R.N.3
  • 6
    • 0037228869 scopus 로고    scopus 로고
    • Optical Coherence Tomography Measurement of Macular and Nerve Fiber Layer Thickness in Normal and Glaucomatous Human Eyes
    • Viviane Guedes, Joel S. Schuman, Ellen Hertzmark et al. "Optical Coherence Tomography Measurement of Macular and Nerve Fiber Layer Thickness in Normal and Glaucomatous Human Eyes" Ophthalmology 2003, 177-189
    • (2003) Ophthalmology , pp. 177-189
    • Guedes, V.1    Schuman, J.S.2    Hertzmark, E.3
  • 7
    • 13544265585 scopus 로고    scopus 로고
    • Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography
    • S. Jiao, R. Knighton, X. Huang, G. Gregori, and C. A. Puliafito, "Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography," Opt. Express, Vol. 13, 444-452 (2005), http://www.opticsexpress.org/abstract.cfm?URI=OPEX-13-2-444.
    • (2005) Opt. Express , vol.13 , pp. 444-452
    • Jiao, S.1    Knighton, R.2    Huang, X.3    Gregori, G.4    Puliafito, C.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.