-
1
-
-
0018665522
-
-
Dantzker DR, Brook CJ, Dehart P, et al. Ventilation-perfusion distribution in the adult respiratory distress syndrome. Am Rev Respir Dis 1979; 120: 1039-52.
-
-
-
-
2
-
-
0033935128
-
-
Hubble CL, Gentile MA, Tripp DS, et al. Deadspace to tidal volume ratio predicts successful extubation in infants and children. Crit Care Med 2000; 28: 2034-40.
-
-
-
-
3
-
-
0025128968
-
-
Courtney SE, Weber KR, Breakie LA, et al. Capillary blood gases in the neonate. A reassessment and review of the literature. Am J Dis Child 1990; 144: 1287-88.
-
-
-
-
4
-
-
0025011350
-
-
Schnapp LM, Cohen NH. Pulse oximetry: uses and abuses. Chest 1990; 98: 1244.
-
-
-
-
5
-
-
0024586470
-
-
Barker SJ, Tremper KK, Hyatt J. Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. Anesthesiology 1989; 70: 113.
-
-
-
-
6
-
-
34248585577
-
-
Meliones J, Wilson BG, Cheifetz IM, et al. Respiratory monitoring. In: Rogers, et al. (eds): Textbook of pediatric intensive care. Baltimore: Williams and Wilkins, 1996. p. 338.
-
-
-
-
7
-
-
0026827401
-
-
2 measurements in ventilated children. Pediatr Pulmonol 1992; 12: 153-7.
-
-
-
-
8
-
-
34248561598
-
-
Martin L. Mechanical ventilation, respiratory monitoring, and the basics of pulmonary physiology. In: Tobias JD. (eds): Paediatric critical care: The essentials., Armonk, NY: Fugura Publishing Co, Inc, 1999. p. 57-105.
-
-
-
-
9
-
-
14544288628
-
-
Krauss B, Deykin A, Lam A, et al. Capnogram shape in obstructive lung disease. Anesth Analg 2005; 100: 884-8.
-
-
-
-
10
-
-
33846691936
-
-
Thompson JE, Jaffe MB. Capnographic waveforms in the mechanically ventilated patient. Respir Care 2005; 50: 100-9.
-
-
-
-
11
-
-
0029795821
-
-
Yaron M, Padyk P, Hutsinpiller M, Cairns CB. Utility of the expiratory capnogram in the assessment of bronchospasm. Ann Emerg Med 1996; 28: 403-7.
-
-
-
-
12
-
-
0021894356
-
-
2 by two non-invasive methods in the critically ill newborn infant. J Pediatr 1985; 106: 282.
-
-
-
-
13
-
-
17444429629
-
Esophageal and gastric pressure measurements
-
Benditt J. Esophageal and gastric pressure measurements. Respir Care 50 (2005) 68-77
-
(2005)
Respir Care
, vol.50
, pp. 68-77
-
-
Benditt, J.1
-
15
-
-
0013965114
-
Deformation of chest wall during breathing effort
-
Agostoni E. Deformation of chest wall during breathing effort. J Appl Physiol 21 (1966) 1827-1832
-
(1966)
J Appl Physiol
, vol.21
, pp. 1827-1832
-
-
Agostoni, E.1
-
16
-
-
34248593926
-
-
Hammer J, Deakers TW, Newth CJ. Lissajous figure analysis in infants with thoracoabdominal asynchrony due to neuromuscular diseases. Am J Respir Crit Care Med 1994; 149: A36.
-
-
-
-
17
-
-
4644328091
-
-
Willis BC, Graham AS, Wetzel RL, Newth CJ. Respiratory inductance plethysmography used to diagnose bilateral diaphragmatic paralysis. A case report. Pediatr Crit Care Med 2004; 5: 399-402.
-
-
-
-
18
-
-
0035209852
-
The influence of endotracheal tube leak on the assessment of respiratory function in ventilated children
-
Main E., Castle R., Stocks J., James I., and Hatch D. The influence of endotracheal tube leak on the assessment of respiratory function in ventilated children. Intensive Care Med 27 (2001) 1788-1797
-
(2001)
Intensive Care Med
, vol.27
, pp. 1788-1797
-
-
Main, E.1
Castle, R.2
Stocks, J.3
James, I.4
Hatch, D.5
-
19
-
-
1342307786
-
-
Newth CJ, Rachman B, Patel N, Hammer J. The use of cuffed versus uncuffed endotracheal tubes in pediatric intensive care J Pediatr 2004; 144: 333-7.
-
-
-
-
20
-
-
0000939976
-
Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
-
ARDS Network
-
ARDS Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 42 (2004) 1301-1308
-
(2004)
N Engl J Med
, vol.42
, pp. 1301-1308
-
-
-
21
-
-
0033924593
-
-
Neve V, de la Roque ED, Leclerc F, et al. Ventilator-induced overdistension in children: dynamic versus low-flow inflation volume-pressure curves. J Respir Crit Care Med 2000; 162: 139-47.
-
-
-
-
22
-
-
0023757635
-
-
Fisher JB, Mammel MC, Coleman JM, et al. Identifying lung overdistention during mechanical ventilation by using volume-pressure loops. Pediatr Pulmonol 1988; 5: 10-4.
-
-
-
-
23
-
-
0023742950
-
-
Smith TC. Impact of PEEP on lung mechanics and work of breathing in severe airflow obstruction. J Appl Physiol 1988; 65: 1488-99.
-
-
-
-
24
-
-
33846312785
-
-
Graham AS, Chandrashekharaiah G, Citak A, Wetzel RC, Newth CJL. Positive end-expiratory pressure and pressure support in peripheral airways obstruction. Intensive Care Med 2007; 33: 120-7.
-
-
-
-
25
-
-
17444420319
-
Measurement of air trapping, intrinsic positive end-expiratory pressure and dynamic hyperinflation in mechanically ventilated patients
-
Blanch L., Bernabe F., and Lucangelo U. Measurement of air trapping, intrinsic positive end-expiratory pressure and dynamic hyperinflation in mechanically ventilated patients. Respir Care 50 (2005) 110-124
-
(2005)
Respir Care
, vol.50
, pp. 110-124
-
-
Blanch, L.1
Bernabe, F.2
Lucangelo, U.3
|