메뉴 건너뛰기




Volumn 17, Issue 2, 2007, Pages 135-142

Indirect measurement of blood pressure using a pulse oximeter in isoflurane anesthetized dogs

Author keywords

Anesthesia; Doppler blood pressure; Noninvasive monitoring; Oscillometric blood pressure

Indexed keywords

CANIS FAMILIARIS;

EID: 34248569701     PISSN: 14793261     EISSN: 14764431     Source Type: Journal    
DOI: 10.1111/j.1476-4431.2007.00226.x     Document Type: Article
Times cited : (9)

References (35)
  • 1
    • 0036758793 scopus 로고    scopus 로고
    • Observations of private veterinary practices in Colorado, with an emphasis on anesthesia
    • Wagner AE Hellyer PW. Observations of private veterinary practices in Colorado, with an emphasis on anesthesia J Vet Med Educ 2002 29 176 182
    • (2002) J Vet Med Educ , vol.29 , pp. 176-182
    • Wagner, A.E.1    Hellyer, P.W.2
  • 3
    • 0016759340 scopus 로고
    • Indirect blood pressure measurement in the dog
    • Garner HE Hahn AW Hartley JW et al Indirect blood pressure measurement in the dog Lab Anim Sci 1975 25 197 202
    • (1975) Lab Anim Sci , vol.25 , pp. 197-202
    • Garner, H.E.1    Hahn, A.W.2    Hartley, J.W.3
  • 4
    • 0022380786 scopus 로고
    • Evaluation of the arterial blood pressure of dogs by two noninvasive methods
    • Chalifoux A Dallaire A Blais D et al Evaluation of the arterial blood pressure of dogs by two noninvasive methods Can J Comp Med 1985 49 419 423
    • (1985) Can J Comp Med , vol.49 , pp. 419-423
    • Chalifoux, A.1    Dallaire, A.2    Blais, D.3
  • 5
    • 0015617768 scopus 로고
    • The accuracy of indirect determination of blood pressure in dogs
    • Glen JB. The accuracy of indirect determination of blood pressure in dogs Res Vet Sci 1973 14 291 295
    • (1973) Res Vet Sci , vol.14 , pp. 291-295
    • Glen, J.B.1
  • 6
    • 0019011073 scopus 로고
    • Indirect mean arterial pressure in the anesthetized dog
    • Geddes LA Combs W Denton W et al Indirect mean arterial pressure in the anesthetized dog Am J Physiol 1980 238 H664 H666
    • (1980) Am J Physiol , vol.238
    • Geddes, L.A.1    Combs, W.2    Denton, W.3
  • 7
    • 0020160129 scopus 로고
    • Noninvasive measurement of systemic arterial pressure in dogs by automatic sphygomomanometry
    • Hamlin RL Kittleson MD Rice D et al Noninvasive measurement of systemic arterial pressure in dogs by automatic sphygomomanometry Am J Vet Res 1982 43 1271 1273
    • (1982) Am J Vet Res , vol.43 , pp. 1271-1273
    • Hamlin, R.L.1    Kittleson, M.D.2    Rice, D.3
  • 8
    • 0025783122 scopus 로고
    • Comparison of direct and indirect blood pressure measurement in anesthetized dogs
    • Sawyer DC Brown M Striler EL et al Comparison of direct and indirect blood pressure measurement in anesthetized dogs Lab Anim Sci 1991 41 134 138
    • (1991) Lab Anim Sci , vol.41 , pp. 134-138
    • Sawyer, D.C.1    Brown, M.2    Striler, E.L.3
  • 9
    • 0029331209 scopus 로고
    • Comparison of direct and indirect pressure measurements in anesthetized dogs
    • Gains MJ Grodecki KM Jacobs RM et al Comparison of direct and indirect pressure measurements in anesthetized dogs Can J Vet Res 1995 59 238 240
    • (1995) Can J Vet Res , vol.59 , pp. 238-240
    • Gains, M.J.1    Grodecki, K.M.2    Jacobs, R.M.3
  • 10
    • 1542426070 scopus 로고    scopus 로고
    • Evaluation of a new oscillometric blood pressure monitor in isoflurane-anesthetized dogs
    • Sawyer DC Guikema AH Siegel EM. Evaluation of a new oscillometric blood pressure monitor in isoflurane-anesthetized dogs Vet Anaesth Analg 2004 31 27 39
    • (2004) Vet Anaesth Analg , vol.31 , pp. 27-39
    • Sawyer, D.C.1    Guikema, A.H.2    Siegel, E.M.3
  • 11
    • 0031991163 scopus 로고    scopus 로고
    • Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs
    • Grosenbaugh DA Muir WW. Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs Am J Vet Res 1998 59 205 211
    • (1998) Am J Vet Res , vol.59 , pp. 205-211
    • Grosenbaugh, D.A.1    Muir, W.W.2
  • 12
    • 0024523226 scopus 로고
    • Principles of pulse oximetry
    • theoretical and practical considerations
    • Alexander CM Teller LE Gross JB. Principles of pulse oximetry theoretical and practical considerations Anesth Analg 1989 68 368 376
    • (1989) Anesth Analg , vol.68 , pp. 368-376
    • Alexander, C.M.1    Teller, L.E.2    Gross, J.B.3
  • 13
    • 0023484540 scopus 로고
    • Comparison of blood pressure measurement by Doppler and by pulse oximetry techniques
    • Wallace CT Baker JD Alpert CC et al Comparison of blood pressure measurement by Doppler and by pulse oximetry techniques Anesth Analg 1987 66 1018 1019
    • (1987) Anesth Analg , vol.66 , pp. 1018-1019
    • Wallace, C.T.1    Baker, J.D.2    Alpert, C.C.3
  • 14
    • 0026541389 scopus 로고
    • Can pulse oximetry be used to measure systolic blood pressure?
    • Chawla R Kumarvel V Girdhar KK et al Can pulse oximetry be used to measure systolic blood pressure? Anesth Analg 1992 74 196 200
    • (1992) Anesth Analg , vol.74 , pp. 196-200
    • Chawla, R.1    Kumarvel, V.2    Girdhar, K.K.3
  • 15
    • 0036896131 scopus 로고    scopus 로고
    • Evaluating the relationship between arterial blood pressure changes and indices of pulse oximetric plethysmography
    • Golparvar M Naddafnia H Saghaei M. Evaluating the relationship between arterial blood pressure changes and indices of pulse oximetric plethysmography Anesth Analg 2002 95 1686 1690
    • (2002) Anesth Analg , vol.95 , pp. 1686-1690
    • Golparvar, M.1    Naddafnia, H.2    Saghaei, M.3
  • 16
    • 0027939254 scopus 로고
    • A comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows
    • Caulkett NA Duke T Bailey JV. A comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows Can J Vet Res 1994 58 144 147
    • (1994) Can J Vet Res , vol.58 , pp. 144-147
    • Caulkett, N.A.1    Duke, T.2    Bailey, J.V.3
  • 17
    • 0032114336 scopus 로고    scopus 로고
    • A comparison of indirect blood pressure monitoring techniques in the anesthetized cat
    • Caulkett NA Cantwell SL Houston DM. A comparison of indirect blood pressure monitoring techniques in the anesthetized cat Vet Surg 1998 27 370 377
    • (1998) Vet Surg , vol.27 , pp. 370-377
    • Caulkett, N.A.1    Cantwell, S.L.2    Houston, D.M.3
  • 19
    • 0023748397 scopus 로고
    • Detection thresholds of nonocclusive intestinal hypoperfusion by Doppler ultrasound, photoplethysmography, and fluorescein
    • Whitehill TA Pearce WH Rosales C et al Detection thresholds of nonocclusive intestinal hypoperfusion by Doppler ultrasound, photoplethysmography, and fluorescein J Vasc Surg 1988 8 28 32
    • (1988) J Vasc Surg , vol.8 , pp. 28-32
    • Whitehill, T.A.1    Pearce, W.H.2    Rosales, C.3
  • 20
    • 17144427244 scopus 로고    scopus 로고
    • Non-invasive monitoring of muscle blood perfusion by photoplethysmography
    • evaluation of a new application
    • Sandberg M Zhang Q Styf J et al Non-invasive monitoring of muscle blood perfusion by photoplethysmography evaluation of a new application Acta Physiol Scand 2005 183 335 343
    • (2005) Acta Physiol Scand , vol.183 , pp. 335-343
    • Sandberg, M.1    Zhang, Q.2    Styf, J.3
  • 21
    • 0042627799 scopus 로고    scopus 로고
    • Initial experience with personal digital assistant-based reflectance photoplethysmograph for free tissue transfer monitoring
    • Stack BC Jr. Futran ND Zang B et al Initial experience with personal digital assistant-based reflectance photoplethysmograph for free tissue transfer monitoring Ann Plast Surg 2003 51 136 140
    • (2003) Ann Plast Surg , vol.51 , pp. 136-140
    • Stack Jr., B.C.1    Futran, N.D.2    Zang, B.3
  • 22
    • 0029816493 scopus 로고    scopus 로고
    • Value of toe pulse waves in addition to systolic pressures in the assessment of the severity of peripheral arterial disease and critical limb ischemia
    • Carter SA Tate RB. Value of toe pulse waves in addition to systolic pressures in the assessment of the severity of peripheral arterial disease and critical limb ischemia J Vasc Surg 1996 24 258 265
    • (1996) J Vasc Surg , vol.24 , pp. 258-265
    • Carter, S.A.1    Tate, R.B.2
  • 23
    • 0026321180 scopus 로고
    • Continuous direct and indirect blood pressure measurement (Finapres) in the critically ill
    • Farquhar IK. Continuous direct and indirect blood pressure measurement (Finapres) in the critically ill Anaesthsiology 1991 46 1050 1055
    • (1991) Anaesthsiology , vol.46 , pp. 1050-1055
    • Farquhar, I.K.1
  • 24
    • 0030021707 scopus 로고    scopus 로고
    • A rapid noninvasive blood pressure measurement method for discrete value and full waveform determination
    • Schnall RP Gavriely N Lewkowicz S et al A rapid noninvasive blood pressure measurement method for discrete value and full waveform determination J Appl Physiol 1996 80 307 314
    • (1996) J Appl Physiol , vol.80 , pp. 307-314
    • Schnall, R.P.1    Gavriely, N.2    Lewkowicz, S.3
  • 25
    • 0031747793 scopus 로고    scopus 로고
    • A comparison between systolic aortic root pressure and finger blood pressure
    • Philippe EG Hebert JL Coirault C et al A comparison between systolic aortic root pressure and finger blood pressure Chest 1998 113 1466 1474
    • (1998) Chest , vol.113 , pp. 1466-1474
    • Philippe, E.G.1    Hebert, J.L.2    Coirault, C.3
  • 26
    • 0029401679 scopus 로고
    • Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood pressure measurement in anesthetized cats
    • Binns SH Sisson DD Buosico D et al Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood pressure measurement in anesthetized cats J Vet Intern Med 1995 9 405 411
    • (1995) J Vet Intern Med , vol.9 , pp. 405-411
    • Binns, S.H.1    Sisson, D.D.2    Buosico, D.3
  • 27
    • 0025411376 scopus 로고
    • Noninvasive measurement of systemic arterial pressure by Finapres in anesthetized dogs
    • Tabaru H Watanabe H Tanaka M et al Noninvasive measurement of systemic arterial pressure by Finapres in anesthetized dogs Jpn J Vet Sci 1990 52 427 430
    • (1990) Jpn J Vet Sci , vol.52 , pp. 427-430
    • Tabaru, H.1    Watanabe, H.2    Tanaka, M.3
  • 28
    • 0023551777 scopus 로고
    • Blood flow limits and pulse oximeter signal detection
    • Lawson D Norley I Korbon G et al Blood flow limits and pulse oximeter signal detection Anesthesiology 1987 67 599 603
    • (1987) Anesthesiology , vol.67 , pp. 599-603
    • Lawson, D.1    Norley, I.2    Korbon, G.3
  • 29
    • 0027479012 scopus 로고
    • National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers
    • White WB Berson AS Robbins C et al National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers Hypertension 1993 21 504 509
    • (1993) Hypertension , vol.21 , pp. 504-509
    • White, W.B.1    Berson, A.S.2    Robbins, C.3
  • 30
    • 0025483920 scopus 로고
    • Adaptation of human oscillometric blood pressure monitors in dogs
    • Hunter JS McGrath CJ Thatcher CD et al Adaptation of human oscillometric blood pressure monitors in dogs Am J Vet Res 1990 51 1439 1442
    • (1990) Am J Vet Res , vol.51 , pp. 1439-1442
    • Hunter, J.S.1    McGrath, C.J.2    Thatcher, C.D.3
  • 31
    • 0030278419 scopus 로고    scopus 로고
    • Comparison of the indirect oscillometric and direct arterial methods for blood pressure measurements in anesthetized dogs
    • Meurs KM Miller MW Slater MR. Comparison of the indirect oscillometric and direct arterial methods for blood pressure measurements in anesthetized dogs J Am Anim Hosp Assoc 1996 32 471 475
    • (1996) J Am Anim Hosp Assoc , vol.32 , pp. 471-475
    • Meurs, K.M.1    Miller, M.W.2    Slater, M.R.3
  • 32
    • 0032932450 scopus 로고    scopus 로고
    • Pulse oximetry
    • principles and limitations
    • Sinex JE. Pulse oximetry principles and limitations Am J Emerg Med 1999 17 59 67
    • (1999) Am J Emerg Med , vol.17 , pp. 59-67
    • Sinex, J.E.1
  • 33
    • 1142267293 scopus 로고    scopus 로고
    • Patient monitoring and clinical measurement
    • In*Hall L.W.*Clarke K.W.*Trim C.M.eds. WB Saunders London pp
    • Hall LW Clarke KW Patient monitoring and clinical measurement In Hall LW Clarke KW Trim CM eds Veterinary Anaesthesia 10th edn London WB Saunders 2001 pp 29 59
    • (2001) Veterinary Anaesthesia 10th edn , pp. 29-59
    • Hall, L.W.1    Clarke, K.W.2
  • 34
    • 0024436717 scopus 로고
    • Cardiovascular effects of vasopressors in isoflurane-anesthetized dogs before and after hemorrhage
    • Curtis MB Bednarski RM Majors L. Cardiovascular effects of vasopressors in isoflurane-anesthetized dogs before and after hemorrhage Am J Vet Res 1989 50 1866 1871
    • (1989) Am J Vet Res , vol.50 , pp. 1866-1871
    • Curtis, M.B.1    Bednarski, R.M.2    Majors, L.3
  • 35
    • 0024437730 scopus 로고
    • Cardiovascular effects of vasopressors in halothane-anesthetized dogs before and after hemorrhage
    • Curtis MB Bednarski RM Majors L. Cardiovascular effects of vasopressors in halothane-anesthetized dogs before and after hemorrhage Am J Vet Res 1989 50 1859 1865
    • (1989) Am J Vet Res , vol.50 , pp. 1859-1865
    • Curtis, M.B.1    Bednarski, R.M.2    Majors, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.