메뉴 건너뛰기




Volumn 1, Issue 4, 2007, Pages 210-215

Effects of temperature and pressure change on positive corona and sparkover under direct voltage in short airgaps

Author keywords

[No Author keywords available]

Indexed keywords

GLOW DISCHARGE CURRENTS; RELATIVE AIR DENSITY;

EID: 34248551263     PISSN: 17518822     EISSN: None     Source Type: Journal    
DOI: 10.1049/iet-smt:20060106     Document Type: Article
Times cited : (9)

References (15)
  • 3
    • 34248589398 scopus 로고
    • Temperature effect on the streamer breakdown of air
    • paper 46.04 New Orleans, LA, USA
    • Feser, K., and Schmid, J.: ' Temperature effect on the streamer breakdown of air ', paper 46.04, Proc. 6th Int. Symp. on High Voltage Engineering, 1989, New Orleans, LA, USA
    • (1989) Proc. 6th Int. Symp. on High Voltage Engineering
    • Feser, K.1    Schmid, J.2
  • 5
    • 0038684961 scopus 로고
    • The breakdown voltage of air in a 50cm rod-plane gap over a practical range of air density and humidity
    • paper 4.02 Germany
    • Geldenhuys, H.J.: ' The breakdown voltage of air in a 50cm rod-plane gap over a practical range of air density and humidity ', paper 4.02, Proc. 5th Int. Symp. on High Voltage Engineering Braunschweig, Germany, 1987
    • (1987) Proc. 5th Int. Symp. on High Voltage Engineering Braunschweig
    • Geldenhuys, H.J.1
  • 6
    • 34248589396 scopus 로고    scopus 로고
    • International Electrotechnics Commission IEC 60060, 1989
    • ' High voltage measurement techniques Part 1 ', International Electrotechnics Commission IEC 60060, 1989
  • 7
    • 33748960635 scopus 로고    scopus 로고
    • Assessment of air density correction for practical electrode systems
    • Boutlendj, M., and Allen, N.L.: ' Assessment of air density correction for practical electrode systems ', Eur. Trans. Electric Power, 1996, 6, p. 267-274
    • (1996) Eur. Trans. Electric Power , vol.6 , pp. 267-274
    • Boutlendj, M.1    Allen, N.L.2
  • 8
    • 0034314072 scopus 로고    scopus 로고
    • Tests on the breakdown of air in non-uniform fields at elevated temperatures
    • 1350-2344
    • Allen, N.L., Lam, D.S.K., and Greaves, D.A.: ' Tests on the breakdown of air in non-uniform fields at elevated temperatures ', IEE Proc., Sci. Meas. Technol., 2000, 147, p. 291-295 1350-2344
    • (2000) IEE Proc., Sci. Meas. Technol. , vol.147 , pp. 291-295
    • Allen, N.L.1    Lam, D.S.K.2    Greaves, D.A.3
  • 10
    • 0014922777 scopus 로고
    • Phenomenes de predecharges entre une pointe et un plan dans l'air sous tension continue
    • Fieux, R., and Boutteau, M.: ' Phenomenes de predecharges entre une pointe et un plan dans l'air sous tension continue ', Bull. Dir. Etud. Rech., 1970, 2, p. 55-88
    • (1970) Bull. Dir. Etud. Rech. , vol.2 , pp. 55-88
    • Fieux, R.1    Boutteau, M.2
  • 12
    • 0004232691 scopus 로고
    • University of California Press, Berkeley, CA, USA
    • Loeb, L.B.: ' Electrical coronas ', (University of California Press, Berkeley, CA, USA, 1965)
    • (1965) Electrical Coronas
    • Loeb, L.B.1
  • 14
    • 33645653841 scopus 로고    scopus 로고
    • Positive corona inception in air at elevated temperatures
    • 1350-2344
    • Allen, N.L., and Kong, J.C.P.: ' Positive corona inception in air at elevated temperatures ', IEE Proc., Sci. Meas. Technol, 2006, 153, (1), p. 31-38 1350-2344
    • (2006) IEE Proc., Sci. Meas. Technol , vol.153 , Issue.1 , pp. 31-38
    • Allen, N.L.1    Kong, J.C.P.2
  • 15
    • 34248577346 scopus 로고    scopus 로고
    • 2003, PhD, University of Manchester Institute of Science and Technology
    • Kong, J.C.P.: ' Corona and breakdown characteristics in air at elevated temperatures ', 2003, PhD, University of Manchester Institute of Science and Technology
    • Kong, J.C.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.