메뉴 건너뛰기




Volumn 33, Issue 3, 2007, Pages 124-129

Experimentally increased intraocular pressure using digital forces

Author keywords

Corneal curvature; Digital forces; Intraocular pressure; Tonometry

Indexed keywords

ARTICLE; CORNEA CURVATURE; CORNEA SENSIBILITY; FORCE; HUMAN; HUMAN EXPERIMENT; INTRAOCULAR HYPERTENSION; NORMAL HUMAN; PRIORITY JOURNAL; RELIABILITY; SCLERA; TONOMETRY;

EID: 34248549102     PISSN: 15422321     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.icl.0000247637.71618.26     Document Type: Article
Times cited : (28)

References (43)
  • 1
    • 0023636296 scopus 로고
    • In vivo determination of Young's modulus for the human cornea
    • Sjontoft E, Edmund C. In vivo determination of Young's modulus for the human cornea. Bull Math Biol 1987;49:217-232.
    • (1987) Bull Math Biol , vol.49 , pp. 217-232
    • Sjontoft, E.1    Edmund, C.2
  • 2
    • 0028931217 scopus 로고
    • Extensibility of the normo-hydrated human cornea
    • Hjortdal JO. Extensibility of the normo-hydrated human cornea. Acta Ophthalmol Scand 1995;73:12-17.
    • (1995) Acta Ophthalmol Scand , vol.73 , pp. 12-17
    • Hjortdal, J.O.1
  • 4
    • 0026581976 scopus 로고
    • Diurnal IOP variations: An analysis of 690 diurnal curves
    • David R, Zangwill L, Briscoe L, et al. Diurnal IOP variations: An analysis of 690 diurnal curves. Br J Ophthalmol 1992;76:280-283.
    • (1992) Br J Ophthalmol , vol.76 , pp. 280-283
    • David, R.1    Zangwill, L.2    Briscoe, L.3
  • 5
    • 34248550723 scopus 로고
    • Valsalva-induced intraocular pressure effects on the corneal curvature
    • Thomas RA, Martinez JA, Nieves J, et al. Valsalva-induced intraocular pressure effects on the corneal curvature. Invest Ophthalmol Vis Sci 1991;32:1000.
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 1000
    • Thomas, R.A.1    Martinez, J.A.2    Nieves, J.3
  • 6
    • 32044449127 scopus 로고
    • Ocular effects of gravity inversion [letter]
    • O'Connor PS, Poirier RH. Ocular effects of gravity inversion [letter]. JAMA 1985;254:756.
    • (1985) JAMA , vol.254 , pp. 756
    • O'Connor, P.S.1    Poirier, R.H.2
  • 7
    • 0029939751 scopus 로고    scopus 로고
    • Mechanical stability of the cornea after radial keratotomy and photorefractive keratotomy
    • Hjortdal JO, Bohm A, Kohlhaas M, et al. Mechanical stability of the cornea after radial keratotomy and photorefractive keratotomy. J Refract Surg 1996;12:459-466.
    • (1996) J Refract Surg , vol.12 , pp. 459-466
    • Hjortdal, J.O.1    Bohm, A.2    Kohlhaas, M.3
  • 8
    • 0021993841 scopus 로고
    • Ocular manifestations of gravity inversion
    • Friberg TR, Weinreb RN. Ocular manifestations of gravity inversion. JAMA 1985;253:1755-1757.
    • (1985) JAMA , vol.253 , pp. 1755-1757
    • Friberg, T.R.1    Weinreb, R.N.2
  • 9
    • 0014128226 scopus 로고
    • Pressure of the lid on the eye
    • Miller D. Pressure of the lid on the eye. Arch Ophthalmol 1967;78: 328-330.
    • (1967) Arch Ophthalmol , vol.78 , pp. 328-330
    • Miller, D.1
  • 10
    • 0014597151 scopus 로고
    • Direct-recorded IOP variations in a human subject
    • Coleman DJ, Trokel S. Direct-recorded IOP variations in a human subject. Arch Ophthalmol 1969;82:637-640.
    • (1969) Arch Ophthalmol , vol.82 , pp. 637-640
    • Coleman, D.J.1    Trokel, S.2
  • 11
    • 0034075177 scopus 로고    scopus 로고
    • Increased intraocular pressure and visual field defects in high resistance wind instruments players
    • Schuman JS, Massicotte EC, Connolly S, et al. Increased intraocular pressure and visual field defects in high resistance wind instruments players. Ophthalmology 2000;107:127-133.
    • (2000) Ophthalmology , vol.107 , pp. 127-133
    • Schuman, J.S.1    Massicotte, E.C.2    Connolly, S.3
  • 12
    • 0009779172 scopus 로고
    • Corticosteroids and intraocular pressure
    • Becker B, Mills DW. Corticosteroids and intraocular pressure. Arch Ophthalmol 1963;70:500-507.
    • (1963) Arch Ophthalmol , vol.70 , pp. 500-507
    • Becker, B.1    Mills, D.W.2
  • 14
    • 34248582551 scopus 로고    scopus 로고
    • Tonometry and intraocular pressure
    • Fingeret M, Lewis T, eds, New York, McGraw-Hill
    • Lalle P. Tonometry and intraocular pressure. In: Fingeret M, Lewis T, eds. Primary Care of the Glaucomas. New York, McGraw-Hill, 2001, p 123.
    • (2001) Primary Care of the Glaucomas , pp. 123
    • Lalle, P.1
  • 15
    • 51249188445 scopus 로고
    • A theoretical and experimental study of the mechanical behavior of the cornea with application to the measurement of IOP
    • Schwartz NJ, Mackay RS, Sackman JL. A theoretical and experimental study of the mechanical behavior of the cornea with application to the measurement of IOP. Bull Math Biophys 1966;28:585-643.
    • (1966) Bull Math Biophys , vol.28 , pp. 585-643
    • Schwartz, N.J.1    Mackay, R.S.2    Sackman, J.L.3
  • 16
    • 32044451001 scopus 로고
    • Prevalence and characteristics of eye rubbing for keratoconic and non-keratoconic subjects
    • Korb DR, Leahy CD, Greiner JV. Prevalence and characteristics of eye rubbing for keratoconic and non-keratoconic subjects. Invest Ophthalmol Vis Sci 1991;32:S884.
    • (1991) Invest Ophthalmol Vis Sci , vol.32
    • Korb, D.R.1    Leahy, C.D.2    Greiner, J.V.3
  • 17
    • 18944368414 scopus 로고    scopus 로고
    • The biomechanics of keratoconus and rigid contact lenses
    • McMonnies CW. The biomechanics of keratoconus and rigid contact lenses. Eye Contact Lens 2005;31:80-92.
    • (2005) Eye Contact Lens , vol.31 , pp. 80-92
    • McMonnies, C.W.1
  • 18
    • 0020436584 scopus 로고
    • Comparison of mechanical properties of keratoconus and normal corneas
    • Nash IS, Greene PR, Foster CS. Comparison of mechanical properties of keratoconus and normal corneas. Exp Eye Res 1982;35:413-423.
    • (1982) Exp Eye Res , vol.35 , pp. 413-423
    • Nash, I.S.1    Greene, P.R.2    Foster, C.S.3
  • 19
    • 0001586615 scopus 로고
    • Corneal pulsation and corneal pulse waves
    • Suzuki I. Corneal pulsation and corneal pulse waves. Jpn J Ophthalmol 1963;6:6-10.
    • (1963) Jpn J Ophthalmol , vol.6 , pp. 6-10
    • Suzuki, I.1
  • 20
    • 0013822268 scopus 로고
    • Tonometry and tonography
    • Gloster J. Tonometry and tonography. Int Ophthalmol Clin 1965;5: 937-951.
    • (1965) Int Ophthalmol Clin , vol.5 , pp. 937-951
    • Gloster, J.1
  • 22
    • 32044434190 scopus 로고
    • Contact lenses in abnormal ocular conditions: Keratoconus
    • Phillips AJ, Stone J, eds, London, Butterworths
    • Woodward EG. Contact lenses in abnormal ocular conditions: Keratoconus. In: Phillips AJ, Stone J, eds. Contact Lenses. London, Butterworths, 1989 p 753.
    • (1989) Contact Lenses , pp. 753
    • Woodward, E.G.1
  • 24
    • 84990581881 scopus 로고
    • Pulsating vision [letter]
    • McMonnies CW. Pulsating vision [letter]. Aus J Optom 1970;53:257.
    • (1970) Aus J Optom , vol.53 , pp. 257
    • McMonnies, C.W.1
  • 25
    • 0003937893 scopus 로고
    • Mathematical models of the dynamics of the human eye
    • Levin S, ed, Berlin, Springer-Verlag
    • Collins R, van der Werff TJ. Mathematical models of the dynamics of the human eye. In: Levin S, ed. Lecture Notes in Biomathematics. Berlin, Springer-Verlag, 1980, p 57.
    • (1980) Lecture Notes in Biomathematics , pp. 57
    • Collins, R.1    van der Werff, T.J.2
  • 26
    • 0020424643 scopus 로고
    • Diurnal variations of corneal topography and thickness
    • Kiely PM, Carney LG, Smith G. Diurnal variations of corneal topography and thickness. Am J Optom Physiol Opt 1982;59:976-982.
    • (1982) Am J Optom Physiol Opt , vol.59 , pp. 976-982
    • Kiely, P.M.1    Carney, L.G.2    Smith, G.3
  • 27
    • 34248571535 scopus 로고
    • Theoretical analysis of the effect of hydration on corneal biomechanics and the results of radial keratometry
    • Roy P, McKinney AE, Chuong CJ, et al. Theoretical analysis of the effect of hydration on corneal biomechanics and the results of radial keratometry. Invest Ophthalmol Vis Sci 1995;36:S39.
    • (1995) Invest Ophthalmol Vis Sci , vol.36
    • Roy, P.1    McKinney, A.E.2    Chuong, C.J.3
  • 28
    • 0027291601 scopus 로고
    • Sources of error with use of Goldmann-type tonometers
    • Whiteacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 1993;38:1-30.
    • (1993) Surv Ophthalmol , vol.38 , pp. 1-30
    • Whiteacre, M.M.1    Stein, R.2
  • 29
    • 0024399832 scopus 로고
    • The effect of increased intraocular pressure on visual acuity and corneal curvature after radial keratotomy
    • Feldman ST, Frucht-Pery J, Weinreb RN, et al. The effect of increased intraocular pressure on visual acuity and corneal curvature after radial keratotomy. Am J Ophthalmol 1989;108:126-129.
    • (1989) Am J Ophthalmol , vol.108 , pp. 126-129
    • Feldman, S.T.1    Frucht-Pery, J.2    Weinreb, R.N.3
  • 30
    • 0016286276 scopus 로고
    • Variations in visual acuity, refraction, and corneal curvature with changes in applanation tension
    • Poinooswarmy D, Roth JA. Variations in visual acuity, refraction, and corneal curvature with changes in applanation tension. Br J Ophthalmol 1974;58:523-528.
    • (1974) Br J Ophthalmol , vol.58 , pp. 523-528
    • Poinooswarmy, D.1    Roth, J.A.2
  • 31
    • 0028925738 scopus 로고
    • In vitro measurement of corneal strain, thickness, and curvature using digital image processing
    • Hjortdal JO, Jensen PK. In vitro measurement of corneal strain, thickness, and curvature using digital image processing. Acta Ophthalmol Scand 1995;73:5-11.
    • (1995) Acta Ophthalmol Scand , vol.73 , pp. 5-11
    • Hjortdal, J.O.1    Jensen, P.K.2
  • 32
    • 3042819311 scopus 로고    scopus 로고
    • Characteristics of corneal ectasia after LASIK for myopia
    • Twa MD, Nichols JJ, Joslin CE, et al. Characteristics of corneal ectasia after LASIK for myopia. Cornea 2004;23:447-457.
    • (2004) Cornea , vol.23 , pp. 447-457
    • Twa, M.D.1    Nichols, J.J.2    Joslin, C.E.3
  • 33
    • 13844310357 scopus 로고    scopus 로고
    • Transient keratectasia caused by intraocular pressure elevation after laser in situ keratomileusis
    • Atsuko T, Toshihiko U, Yuichi O, et al. Transient keratectasia caused by intraocular pressure elevation after laser in situ keratomileusis. J Cataract Refract Surg 2005;31:202-204.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 202-204
    • Atsuko, T.1    Toshihiko, U.2    Yuichi, O.3
  • 34
    • 0025516422 scopus 로고
    • XPERT™ NCT™: A clinical evaluation
    • Myers KJ, Lalle P, Litwak A, et al. XPERT™ NCT™: A clinical evaluation. J Am Optom Assoc 1990;61:863-869.
    • (1990) J Am Optom Assoc , vol.61 , pp. 863-869
    • Myers, K.J.1    Lalle, P.2    Litwak, A.3
  • 36
    • 31944441523 scopus 로고
    • Mechanics and analysis of tonometry procedures by finite element modeling of the corneoscleral shell
    • Ghista DN, ed, New York, Marcel Dekker
    • Kobayashi AS. Mechanics and analysis of tonometry procedures by finite element modeling of the corneoscleral shell. In: Ghista DN, ed. Biomechanics of Medical Devices. New York, Marcel Dekker, 1981, pp 75-121.
    • (1981) Biomechanics of Medical Devices , pp. 75-121
    • Kobayashi, A.S.1
  • 37
    • 34248580744 scopus 로고
    • Tonometry
    • Duane TD, ed, Philadelphia, Harper Row
    • Brubaker RF. Tonometry. In: Duane TD, ed. Clinical Ophthalmology, vol. 3. Philadelphia, Harper Row, 1987, pp 1-7.
    • (1987) Clinical Ophthalmology , vol.3 , pp. 1-7
    • Brubaker, R.F.1
  • 38
    • 0001484543 scopus 로고
    • Tonographic method for measuring the facility and rate of aqueous flow in human eyes
    • Grant MW. Tonographic method for measuring the facility and rate of aqueous flow in human eyes. Arch Ophthalmol 1950;44:204-214.
    • (1950) Arch Ophthalmol , vol.44 , pp. 204-214
    • Grant, M.W.1
  • 39
    • 0036828027 scopus 로고    scopus 로고
    • Corneal topography after ocular rubbing
    • Mansour A, Haddad R. Corneal topography after ocular rubbing. Cornea 2002;21:756-758.
    • (2002) Cornea , vol.21 , pp. 756-758
    • Mansour, A.1    Haddad, R.2
  • 40
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyser
    • Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyser. J Cataract Refract Surg 2005;31: 156-162.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 41
    • 18044376207 scopus 로고    scopus 로고
    • Considerations of glaucoma in patients undergoing corneal refractive surgery
    • Bashford KP, Shafranov G, Tauber S, et al. Considerations of glaucoma in patients undergoing corneal refractive surgery. Surv Ophthalmol 2005;50:245-251.
    • (2005) Surv Ophthalmol , vol.50 , pp. 245-251
    • Bashford, K.P.1    Shafranov, G.2    Tauber, S.3
  • 42
    • 0035164568 scopus 로고    scopus 로고
    • Real time intraocular pressure and lamellar corneal flap thickness in keratomileusis
    • Kasetsuwan N, Pangilinan RT, Moreira LL, et al. Real time intraocular pressure and lamellar corneal flap thickness in keratomileusis. Cornea 2001;20:41-44.
    • (2001) Cornea , vol.20 , pp. 41-44
    • Kasetsuwan, N.1    Pangilinan, R.T.2    Moreira, L.L.3
  • 43
    • 20544457621 scopus 로고    scopus 로고
    • Assessment of nerve fiber layer thickness before and after laser in situ keratomileusis using scanning laser polarimetry with variable corneal compensation
    • Halkiadakis I, Anglionto L, Ferensowicz M, et al. Assessment of nerve fiber layer thickness before and after laser in situ keratomileusis using scanning laser polarimetry with variable corneal compensation. J Cataract Refract Surg 2005;31:1035-1041.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1035-1041
    • Halkiadakis, I.1    Anglionto, L.2    Ferensowicz, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.