Evidence for heat losses via party wall cavities in masonry construction

Author keywords

[No Author keywords available]

Indexed keywords

HEAT LOSSES; HOUSING; INFRARED IMAGING; STRUCTURAL DESIGN; THERMAL INSULATION;

EID: 34248549045     PISSN: 01436244     EISSN: None     Source Type: Journal    
DOI: 10.1177/0143624407077196     Document Type: Article
Times cited : (60)

References (26)
  • 4
    • 34248521845 scopus 로고    scopus 로고
    • Wingfield J, Bell M, Bell JM, Lowe RJ. Evaluating the Impact of an Enhanced Energy Performance Standard on Load-Bearing Masonry Domestic Construction, Partners in Innovation CI 39/3/663, Interim Report Number 5 - Post Construction Testing and Envelope Performance. Leeds: Centre for the Built Environment, Leeds Metropolitan University, 2006.
    • Wingfield J, Bell M, Bell JM, Lowe RJ. Evaluating the Impact of an Enhanced Energy Performance Standard on Load-Bearing Masonry Domestic Construction, Partners in Innovation CI 39/3/663, Interim Report Number 5 - Post Construction Testing and Envelope Performance. Leeds: Centre for the Built Environment, Leeds Metropolitan University, 2006.
  • 5
    • 34248555333 scopus 로고    scopus 로고
    • Evaluating the Impact of an Enhanced Energy Performance Standard on Load-Bearing Masonry Construction, Partners in Innovation CI 39/3/663
    • No 2, Design Process, Leeds: Centre for the Built Environment, Leeds Metropolitan University
    • Roberts D, Bell M, Lowe RJ. Evaluating the Impact of an Enhanced Energy Performance Standard on Load-Bearing Masonry Construction, Partners in Innovation CI 39/3/663, Interim Report No 2 - Design Process, Leeds: Centre for the Built Environment, Leeds Metropolitan University, 2004.
    • (2004) Interim Report
    • Roberts, D.1    Bell, M.2    Lowe, R.J.3
  • 6
    • 34248555332 scopus 로고    scopus 로고
    • Evaluating the Impact of an Enhanced Energy Performance Standard on Load-Bearing Masonry Domestic Construction, Partners in Innovation CI 39/3/663
    • Number 4, Construction Process. Leeds: Centre for the Built Environment, Leeds Metropolitan University
    • Roberts D, Andersson M, Lowe RJ, Bell M, Wingfield J. Evaluating the Impact of an Enhanced Energy Performance Standard on Load-Bearing Masonry Domestic Construction, Partners in Innovation CI 39/3/663, Interim Report Number 4 - Construction Process. Leeds: Centre for the Built Environment, Leeds Metropolitan University, 2005.
    • (2005) Interim Report
    • Roberts, D.1    Andersson, M.2    Lowe, R.J.3    Bell, M.4    Wingfield, J.5
  • 8
    • 34248555334 scopus 로고    scopus 로고
    • Stephen RK. Airtightness in UK dwellings, IP 1/00. Watford: BRE, 2000.
    • Stephen RK. Airtightness in UK dwellings, IP 1/00. Watford: BRE, 2000.
  • 9
    • 34248526891 scopus 로고    scopus 로고
    • Assessment of energy efficiency impact of Building Regulations compliance
    • 219683. Watford: BRE
    • Grigg P. Assessment of energy efficiency impact of Building Regulations compliance, Client Report 219683. Watford: BRE, 2004.
    • (2004) Client Report
    • Grigg, P.1
  • 15
    • 34248558818 scopus 로고    scopus 로고
    • BS EN ISO 6946: 1997 Building components and building elements - Thermal resistance and thermal transmittance - Calculation method.
    • BS EN ISO 6946: 1997 Building components and building elements - Thermal resistance and thermal transmittance - Calculation method.
  • 22
    • 0018680652 scopus 로고
    • Locating and eliminating obscure but major energy losses in residential housing
    • Harrje DT, Dutt GS, Beyea JE. Locating and eliminating obscure but major energy losses in residential housing. ASHRAE Transactions 1979; 85: 521-34.
    • (1979) ASHRAE Transactions , vol.85 , pp. 521-534
    • Harrje, D.T.1    Dutt, G.S.2    Beyea, J.E.3
  • 23
    • 77956175567 scopus 로고    scopus 로고
    • Field investigations of the thermal performance (U-values) of construction elements - as built
    • 78132. Watford: BRE
    • Doran S. Field investigations of the thermal performance (U-values) of construction elements - as built, BRE Report 78132. Watford: BRE, 2000.
    • (2000) BRE Report
    • Doran, S.1
  • 24
    • 34248537418 scopus 로고    scopus 로고
    • Improving the thermal performance of buildings in practice
    • 222392. Watford: BRE
    • Doran S. Improving the thermal performance of buildings in practice, BRE Client Report 222392. Watford: BRE, 2005.
    • (2005) BRE Client Report
    • Doran, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.