1
-
-
9644262410
-
The Effects of Glenoid Component Alignment Variations on Cement Mantle Stresses in Total Shoulder Arthroplasty
-
Hopkins, A. R., Hansen, U. N., Amis, A. A., and Emery, R., 2004, "The Effects of Glenoid Component Alignment Variations on Cement Mantle Stresses in Total Shoulder Arthroplasty," J. Shoulder Elbow Surg., 13(6), pp. 668-675.
-
(2004)
J. Shoulder Elbow Surg
, vol.13
, Issue.6
, pp. 668-675
-
-
Hopkins, A.R.1
Hansen, U.N.2
Amis, A.A.3
Emery, R.4
-
2
-
-
34248159918
-
Finite Element Analysis of an Offset Keeled Glenoid Prosthesis Compared to a Centre Keeled Design
-
Dublin, August 27-30
-
Murphy, L. A., Prendergast, P. J., Christie, R., and Resch, H., 2000, "Finite Element Analysis of an Offset Keeled Glenoid Prosthesis Compared to a Centre Keeled Design," Proceedings of 12th Conference of the European Society of Biomechanics, Dublin, August 27-30.
-
(2000)
Proceedings of 12th Conference of the European Society of Biomechanics
-
-
Murphy, L.A.1
Prendergast, P.J.2
Christie, R.3
Resch, H.4
-
3
-
-
0033804579
-
Three-Dimensional Finite Element Analysis of Glenoid Replacement Prostheses: A Comparison of Keeled and Pegged Anchorage Systems
-
Lacroix, D., Murphy, L. A., and Prendergast, P. J., 2000, "Three-Dimensional Finite Element Analysis of Glenoid Replacement Prostheses: A Comparison of Keeled and Pegged Anchorage Systems," J. Biomech. Eng., 122, pp. 430-436.
-
(2000)
J. Biomech. Eng
, vol.122
, pp. 430-436
-
-
Lacroix, D.1
Murphy, L.A.2
Prendergast, P.J.3
-
4
-
-
34248138875
-
Stress Analysis of Cemented and Uncemented Glenoid Prostheses
-
Dublin, August 27-30
-
Gupta, S., van der Helm, F. C. T., and van Keulen, A., 2000, "Stress Analysis of Cemented and Uncemented Glenoid Prostheses," Proceedings of 12th Conference of the European Society of Biomechanics, Dublin, August 27-30.
-
(2000)
Proceedings of 12th Conference of the European Society of Biomechanics
-
-
Gupta, S.1
van der Helm, F.C.T.2
van Keulen, A.3
-
5
-
-
0026605414
-
Mechanism and Clinical Significance of Wear Debris-Induced Osteolysis
-
Amstutz, H. C., Campbell, P., Kossovsky, N., and Clarke, I. C., 1992, "Mechanism and Clinical Significance of Wear Debris-Induced Osteolysis," Clin. Orthop. Relat. Res., 276, pp. 7-18.
-
(1992)
Clin. Orthop. Relat. Res
, vol.276
, pp. 7-18
-
-
Amstutz, H.C.1
Campbell, P.2
Kossovsky, N.3
Clarke, I.C.4
-
6
-
-
0030632734
-
Biological Reaction to Debris in Relation to Joint Prostheses
-
Revell, P. A., AL-Saffar, N., and Kobayashi, A., 1997, "Biological Reaction to Debris in Relation to Joint Prostheses," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 211, pp. 187-197.
-
(1997)
Proc. Inst. Mech. Eng., Part H: J. Eng. Med
, vol.211
, pp. 187-197
-
-
Revell, P.A.1
AL-Saffar, N.2
Kobayashi, A.3
-
7
-
-
0033628937
-
Biological Reactions to Wear Debris in Total Joint Replacement
-
Ingham, E., and Fisher, J., 2000, "Biological Reactions to Wear Debris in Total Joint Replacement," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 214, pp. 21-37.
-
(2000)
Proc. Inst. Mech. Eng., Part H: J. Eng. Med
, vol.214
, pp. 21-37
-
-
Ingham, E.1
Fisher, J.2
-
8
-
-
0031544587
-
Wear in Retrieved Condylar Knee Arthroplasties: A Comparison of Wear in Different Designs of 280 Retrieved Condylar Knee Prostheses
-
Blunn, G. W., Joshi, A. B., Minns, R. J., Lidgren, L., Lilley, P., Ryd, L., Engelbrecht, E., and Walker, P. S., 1997, "Wear in Retrieved Condylar Knee Arthroplasties: A Comparison of Wear in Different Designs of 280 Retrieved Condylar Knee Prostheses," J. Arthroplasty, 12, pp. 281-290.
-
(1997)
J. Arthroplasty
, vol.12
, pp. 281-290
-
-
Blunn, G.W.1
Joshi, A.B.2
Minns, R.J.3
Lidgren, L.4
Lilley, P.5
Ryd, L.6
Engelbrecht, E.7
Walker, P.S.8
-
9
-
-
34248182425
-
The Influence of Activity Level on Wear, Counterface Roughness and Frictional Torque of CoCr-UHMWPE Total Hip Replacements
-
Dublin, August 27-30
-
Bowsher, J. G., and Shelton, J. C., 2000, "The Influence of Activity Level on Wear, Counterface Roughness and Frictional Torque of CoCr-UHMWPE Total Hip Replacements," Proceedings of 12th Conference of the European Society of Biomechanics, Dublin, August 27-30.
-
(2000)
Proceedings of 12th Conference of the European Society of Biomechanics
-
-
Bowsher, J.G.1
Shelton, J.C.2
-
10
-
-
0033647807
-
Wear of Ultra-High Molecular Weight Polyethylene (UHMWPE) in Total Knee Prostheses: A Review of Key Influences
-
McGloughlin, T. M., and Kavanagh, A. G., 2000, "Wear of Ultra-High Molecular Weight Polyethylene (UHMWPE) in Total Knee Prostheses: A Review of Key Influences," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 214, pp. 349-359.
-
(2000)
Proc. Inst. Mech. Eng., Part H: J. Eng. Med
, vol.214
, pp. 349-359
-
-
McGloughlin, T.M.1
Kavanagh, A.G.2
-
11
-
-
0030631045
-
Factors Contributing to the Wear of Polyethylene in Clinical Practice
-
Learmonth, I. D., and Cannigham, J. L., 1997, "Factors Contributing to the Wear of Polyethylene in Clinical Practice," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 211, pp. 49-57.
-
(1997)
Proc. Inst. Mech. Eng., Part H: J. Eng. Med
, vol.211
, pp. 49-57
-
-
Learmonth, I.D.1
Cannigham, J.L.2
-
12
-
-
34248136892
-
Comparison of Polyethylene Wear Particles Isolated From Failed Total Hip and Total Shoulder Arthroplasties
-
Mabrey, J. D., Landry, M. E., Huang, D., Dean, D. D., Blanchard, C. R., Boyan, B. D., Wirth, M. A., Rockwood, C. A., and Agrawal, C. M., 1998, "Comparison of Polyethylene Wear Particles Isolated From Failed Total Hip and Total Shoulder Arthroplasties," Proceedings of Transactions of the Annual Meeting of the ORS.
-
(1998)
Proceedings of Transactions of the Annual Meeting of the ORS
-
-
Mabrey, J.D.1
Landry, M.E.2
Huang, D.3
Dean, D.D.4
Blanchard, C.R.5
Boyan, B.D.6
Wirth, M.A.7
Rockwood, C.A.8
Agrawal, C.M.9
-
13
-
-
0034233057
-
Implant Retrieval Studies of the Wear and Loosening of Prosthetic Joints: A Review
-
McGee, M. A., Howie, D. W., Costi, K., Haynes, D. R., Wildenauer, C. J., Pearcy, M. J., and McLean, J. D., 2000, "Implant Retrieval Studies of the Wear and Loosening of Prosthetic Joints: A Review," Wear, 241, pp. 158-165.
-
(2000)
Wear
, vol.241
, pp. 158-165
-
-
McGee, M.A.1
Howie, D.W.2
Costi, K.3
Haynes, D.R.4
Wildenauer, C.J.5
Pearcy, M.J.6
McLean, J.D.7
-
14
-
-
0034485152
-
Glenohumeral Contact Forces
-
Anglin, C., Wyss, U. P., and Pichora, D. R., 2000, "Glenohumeral Contact Forces," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 214, pp. 637-644.
-
(2000)
Proc. Inst. Mech. Eng., Part H: J. Eng. Med
, vol.214
, pp. 637-644
-
-
Anglin, C.1
Wyss, U.P.2
Pichora, D.R.3
-
15
-
-
33846114846
-
Polyethylene Damage of Glenoid Components from Total Shoulder Replacements as Determined from Retrieval Analysis
-
San Francisco, CA, February 25-28
-
Gillis, A., and Li, S., 2001, "Polyethylene Damage of Glenoid Components from Total Shoulder Replacements as Determined from Retrieval Analysis," Proceedings of 47th Meeting of the Orthopaedic Research Society, San Francisco, CA, February 25-28.
-
(2001)
Proceedings of 47th Meeting of the Orthopaedic Research Society
-
-
Gillis, A.1
Li, S.2
-
16
-
-
0036157670
-
Retrieved Glenoid Components - A Classification System for Surface Damage Analysis
-
Gunther, S. B., Graham, J., Norris, T. R., Ries, M. D., and Pruitt, L., 2002, "Retrieved Glenoid Components - A Classification System for Surface Damage Analysis," J. Arthroplasty, 17(1), pp. 95-100.
-
(2002)
J. Arthroplasty
, vol.17
, Issue.1
, pp. 95-100
-
-
Gunther, S.B.1
Graham, J.2
Norris, T.R.3
Ries, M.D.4
Pruitt, L.5
-
17
-
-
0037628986
-
Observations on Retrieved Glenoid Components
-
Hertel, R., and Ballmer, F. T., 2003, "Observations on Retrieved Glenoid Components," J. Arthroplasty, 18(3), pp. 361-366.
-
(2003)
J. Arthroplasty
, vol.18
, Issue.3
, pp. 361-366
-
-
Hertel, R.1
Ballmer, F.T.2
-
18
-
-
34248168071
-
Physical Changes in Polyethylene Glenoid Components After "In Vivo" Use
-
Scarlat, M. M., Goldberg, B. A., and Matsen, F. A., 2000, "Physical Changes in Polyethylene Glenoid Components After "In Vivo" Use," J. Shoulder Elbow Surg., 9(6), p. 550.
-
(2000)
J. Shoulder Elbow Surg
, vol.9
, Issue.6
, pp. 550
-
-
Scarlat, M.M.1
Goldberg, B.A.2
Matsen, F.A.3
-
19
-
-
0034878494
-
Observations on Retreived Polyethylene Glenoid Components
-
Scarlat, M. M., and Matsen, F. A., 2001, "Observations on Retreived Polyethylene Glenoid Components," J. Arthroplasty, 16(6), pp. 795-801.
-
(2001)
J. Arthroplasty
, vol.16
, Issue.6
, pp. 795-801
-
-
Scarlat, M.M.1
Matsen, F.A.2
-
20
-
-
0345004140
-
Isolation and Characterization of Polyethylene Wear Debris Associated with Osteolysis Following Total Shoulder Arthroplasty
-
Wirth, M. A., Agrawal, C. M., Mabrey, J. D., Dean, D. D., Blanchard, C. R., Miller, M. A., and Rockwood, C. A., 1999, "Isolation and Characterization of Polyethylene Wear Debris Associated with Osteolysis Following Total Shoulder Arthroplasty," J. Bone Joint Surg. Br., 81A(1), pp. 29-37.
-
(1999)
J. Bone Joint Surg. Br
, vol.81 A
, Issue.1
, pp. 29-37
-
-
Wirth, M.A.1
Agrawal, C.M.2
Mabrey, J.D.3
Dean, D.D.4
Blanchard, C.R.5
Miller, M.A.6
Rockwood, C.A.7
-
21
-
-
0036897561
-
The Influence of Glenohumeral Prosthetic Mismatch on Glenoid Radiolucent Lines: Results of a Multicenter Study
-
Walch, G., Edwards, T. B., Boulahia, A., Boileau, P., Molé, D., and Adeleine, P., 2002, "The Influence of Glenohumeral Prosthetic Mismatch on Glenoid Radiolucent Lines: Results of a Multicenter Study," J. Bone Joint Surg. Br., 84A, pp. 2186-2191.
-
(2002)
J. Bone Joint Surg. Br
, vol.84 A
, pp. 2186-2191
-
-
Walch, G.1
Edwards, T.B.2
Boulahia, A.3
Boileau, P.4
Molé, D.5
Adeleine, P.6
-
22
-
-
33745742422
-
Influence of Glenohumeral Conformity After Total Shoulder Arthroplasty
-
Terrier, A., Büchler, P., and Farron, A., 2006, "Influence of Glenohumeral Conformity After Total Shoulder Arthroplasty," J. Shoulder Elbow Surg., 15, pp. 515-520.
-
(2006)
J. Shoulder Elbow Surg
, vol.15
, pp. 515-520
-
-
Terrier, A.1
Büchler, P.2
Farron, A.3
-
23
-
-
0038530703
-
Contact Stresses in the Glenoid Component in Total Shoulder Arthroplasty
-
Swieszkowski, W., Bednarz, P., and Prendergast, P. J., 2002, "Contact Stresses in the Glenoid Component in Total Shoulder Arthroplasty," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 217, pp. 49-57.
-
(2002)
Proc. Inst. Mech. Eng., Part H: J. Eng. Med
, vol.217
, pp. 49-57
-
-
Swieszkowski, W.1
Bednarz, P.2
Prendergast, P.J.3
-
24
-
-
0036632076
-
Cemented Polyethylene Versus Uncemented Metal-Backed Glenoid Components in Total Shoulder Arthroplasty: A Prospective, Double-Blind, Randomized Study
-
Boileau, P., Avidor, C., Krishnan, S. G., Walch, G., Kempf, J.-F., and Molé, D., 2002, "Cemented Polyethylene Versus Uncemented Metal-Backed Glenoid Components in Total Shoulder Arthroplasty: A Prospective, Double-Blind, Randomized Study," J. Shoulder Elbow Surg., 11(4), pp. 351-359.
-
(2002)
J. Shoulder Elbow Surg
, vol.11
, Issue.4
, pp. 351-359
-
-
Boileau, P.1
Avidor, C.2
Krishnan, S.G.3
Walch, G.4
Kempf, J.-F.5
Molé, D.6
-
25
-
-
34248209025
-
Total Shoulder Arthroplasty With an Uncemented Glenoid Component: 5 to 13-Year Follow-Up
-
Rosemont, IL
-
Martin, S. A., Zurakowski, D., and Thornhill, T. S., 2002, "Total Shoulder Arthroplasty With an Uncemented Glenoid Component: 5 to 13-Year Follow-Up," Proceedings of Annual Meeting of the American Academy of Orthopaedic Surgeons, Rosemont, IL.
-
(2002)
Proceedings of Annual Meeting of the American Academy of Orthopaedic Surgeons
-
-
Martin, S.A.1
Zurakowski, D.2
Thornhill, T.S.3
-
26
-
-
34248210073
-
Uncemented Glenoid in Total Shoulder: A Five- to Thirteen-Year Follow-up
-
New Orleans, LA
-
Martin, S. A., Zurakowski, D., and Thornhill, T. S., 2003, "Uncemented Glenoid in Total Shoulder: A Five- to Thirteen-Year Follow-up," Proceedings of Annual Meeting of the American Academy of Orthopaedic Surgeons, New Orleans, LA.
-
(2003)
Proceedings of Annual Meeting of the American Academy of Orthopaedic Surgeons
-
-
Martin, S.A.1
Zurakowski, D.2
Thornhill, T.S.3
-
27
-
-
2442759527
-
Comparison of Acetabular Polyethylene Wear in Cemented Versus Cementless Hip Arthroplasty Using 3-D Technique
-
Chicago, IL
-
Robinson, E. J., Devane, P. A., Bourne, P. A., Rorabeck, C. H., and Hardie, R., 1995, "Comparison of Acetabular Polyethylene Wear in Cemented Versus Cementless Hip Arthroplasty Using 3-D Technique," Proceedings of Annual Meeting of the American Academy of Orthopaedic Surgeons, Chicago, IL.
-
(1995)
Proceedings of Annual Meeting of the American Academy of Orthopaedic Surgeons
-
-
Robinson, E.J.1
Devane, P.A.2
Bourne, P.A.3
Rorabeck, C.H.4
Hardie, R.5
-
28
-
-
0030198688
-
Adaptive Finite Element Modelling of Long-Term Polyethylene Wear in Total Hip Arthroplasty
-
Maxian, T. A., Brown, T. D., Pedersen, D. R., and Callaghan, J. J., 1996, "Adaptive Finite Element Modelling of Long-Term Polyethylene Wear in Total Hip Arthroplasty," J. Orthop. Res., 14(4), pp. 668-675.
-
(1996)
J. Orthop. Res
, vol.14
, Issue.4
, pp. 668-675
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
29
-
-
0030345394
-
3-Dimensional Sliding/Contact Computational Simulation of Total Hip Wear
-
Maxian, T. A., Brown, T. D., Pedersen, D. R., and Callaghan, J. J., 1996, "3-Dimensional Sliding/Contact Computational Simulation of Total Hip Wear," Clin. Orthop. Relat. Res., 333, pp. 41-50.
-
(1996)
Clin. Orthop. Relat. Res
, vol.333
, pp. 41-50
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
30
-
-
0030152744
-
A Sliding-Distance-Coupled Finite Element Formulation for Polyethylene Wear in Total Hip Arthroplasty
-
Maxian, T. A., Brown, T. D., Pedersen, D. R., and Callaghan, J. J., 1996, "A Sliding-Distance-Coupled Finite Element Formulation for Polyethylene Wear in Total Hip Arthroplasty," J. Biomech., 29(5), pp. 687-692.
-
(1996)
J. Biomech
, vol.29
, Issue.5
, pp. 687-692
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
31
-
-
0030698011
-
Finite Element Analysis of Acetabular Wear - Validation, and Backing and Fixation Effects
-
Maxian, T. A., Brown, T. D., Pedersen, D. R., McKellop, H. A., Lu, B., and Callaghan, J. J., 1997, "Finite Element Analysis of Acetabular Wear - Validation, and Backing and Fixation Effects," Clin. Orthop. Relat. Res., 344, pp. 111-117.
-
(1997)
Clin. Orthop. Relat. Res
, vol.344
, pp. 111-117
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
McKellop, H.A.4
Lu, B.5
Callaghan, J.J.6
-
33
-
-
0023868463
-
On the Dependence of the Elasticity and Strength of Cancellous Bone on Apparent Density
-
Rice, J. C., Cowin, S. C., and Bowman, J. A., 1988, "On the Dependence of the Elasticity and Strength of Cancellous Bone on Apparent Density," J. Biomech., 21, pp. 155-168.
-
(1988)
J. Biomech
, vol.21
, pp. 155-168
-
-
Rice, J.C.1
Cowin, S.C.2
Bowman, J.A.3
-
34
-
-
0023901292
-
Stiffness of Compact Bone: Effects of Porosity and Density
-
Schaffler, M. B., and Burr, D. B., 1988, "Stiffness of Compact Bone: Effects of Porosity and Density," J. Biomech., 21, pp. 13-16.
-
(1988)
J. Biomech
, vol.21
, pp. 13-16
-
-
Schaffler, M.B.1
Burr, D.B.2
-
35
-
-
0345471427
-
Material Properties Assignment to Finite Element Models of Bone Structures: A New Method
-
Zannoni, C., Mantovani, R., and Viceconti, M., 1998, "Material Properties Assignment to Finite Element Models of Bone Structures: A New Method," Med. Eng. Phys., 20, pp. 753-740.
-
(1998)
Med. Eng. Phys
, vol.20
, pp. 753-740
-
-
Zannoni, C.1
Mantovani, R.2
Viceconti, M.3
-
36
-
-
0035235280
-
A Three-Dimensional Finite Element Model from Computed Tomography: A Semi-Automated Method
-
Cattaneo, P. M., Dalstra, M., and Frich, L. H., 2001, "A Three-Dimensional Finite Element Model from Computed Tomography: A Semi-Automated Method," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 215, pp. 203-213.
-
(2001)
Proc. Inst. Mech. Eng., Part H: J. Eng. Med
, vol.215
, pp. 203-213
-
-
Cattaneo, P.M.1
Dalstra, M.2
Frich, L.H.3
-
37
-
-
0036169065
-
An Elasto-Plastic Finite Element Model for Polyethylene Wear in Total Hip Arthroplasty
-
Teoh, S. H., Chan, W. H., and Thampuran, R., 2002, "An Elasto-Plastic Finite Element Model for Polyethylene Wear in Total Hip Arthroplasty," J. Biomech., 35, pp. 323-330.
-
(2002)
J. Biomech
, vol.35
, pp. 323-330
-
-
Teoh, S.H.1
Chan, W.H.2
Thampuran, R.3
-
38
-
-
0033094925
-
Stress Analysis of Glenoid Components in Total Shoulder Arthroplasty
-
Stone, K. D., Grabowski, J. J., Cofield, R. H., Morrey, B. F., and An, K. N., 1999, "Stress Analysis of Glenoid Components in Total Shoulder Arthroplasty," J. Shoulder Elbow Surg., 8(2), pp. 151-158.
-
(1999)
J. Shoulder Elbow Surg
, vol.8
, Issue.2
, pp. 151-158
-
-
Stone, K.D.1
Grabowski, J.J.2
Cofield, R.H.3
Morrey, B.F.4
An, K.N.5
-
39
-
-
0028439509
-
Analysis of the Kinematic and Dynamic Behaviour of the Shoulder Mechanism
-
van der Helm, F. C. T., 1994, "Analysis of the Kinematic and Dynamic Behaviour of the Shoulder Mechanism," J. Biomech., 27(5), pp. 527-550.
-
(1994)
J. Biomech
, vol.27
, Issue.5
, pp. 527-550
-
-
van der Helm, F.C.T.1
-
40
-
-
0017235260
-
Normal and Abnormal Motion of the Shoulder
-
Poppen, N. K., and Walker, P. S., 1976, "Normal and Abnormal Motion of the Shoulder," J. Bone Joint Surg. Br., 58A(2), pp. 195-201.
-
(1976)
J. Bone Joint Surg. Br
, vol.58 A
, Issue.2
, pp. 195-201
-
-
Poppen, N.K.1
Walker, P.S.2
-
41
-
-
0002379195
-
Observation on the Function of the Shoulder Joint
-
Inman, V. T., Saunders, J. B. M., and Abbot, L. C., 1944, "Observation on the Function of the Shoulder Joint," J. Bone Joint Surg. Br., 26A, pp. 195-201.
-
(1944)
J. Bone Joint Surg. Br
, vol.26 A
, pp. 195-201
-
-
Inman, V.T.1
Saunders, J.B.M.2
Abbot, L.C.3
-
42
-
-
13344270633
-
Contact and Rubbing of Flat Surfaces
-
Archard, J. F., 1953, "Contact and Rubbing of Flat Surfaces," J. Appl. Physiol., 24, pp. 981-988.
-
(1953)
J. Appl. Physiol
, vol.24
, pp. 981-988
-
-
Archard, J.F.1
-
43
-
-
0034154370
-
Shoulder Prosthesis Subluxation: Theory and Experiment
-
Anglin, C., Wyss, U. P., and Pichora, D. R., 2000, "Shoulder Prosthesis Subluxation: Theory and Experiment," J. Shoulder Elbow Surg., 9(2), pp. 104-114.
-
(2000)
J. Shoulder Elbow Surg
, vol.9
, Issue.2
, pp. 104-114
-
-
Anglin, C.1
Wyss, U.P.2
Pichora, D.R.3
-
45
-
-
0036137726
-
Simulation of Knee Joint Replacement During a Gait Cycle Using Explicit Finite Element Analysis
-
Godest, A. C., Beaugonin, M., Haug, E., Taylor, M., and Gregson, P. J., 2002, "Simulation of Knee Joint Replacement During a Gait Cycle Using Explicit Finite Element Analysis," J. Biomech., 35, pp. 267-275.
-
(2002)
J. Biomech
, vol.35
, pp. 267-275
-
-
Godest, A.C.1
Beaugonin, M.2
Haug, E.3
Taylor, M.4
Gregson, P.J.5
-
46
-
-
33748447676
-
Finite Element Modelling of Glenohumeral Kinematics Following Total Shoulder Arthroplasty
-
Hopkins, A. R., Hansen, U. N., Amis, A. A., Taylor, M., Gronau, N., and Anglin, C., 2006, "Finite Element Modelling of Glenohumeral Kinematics Following Total Shoulder Arthroplasty," J. Biomech., 39, pp. 2476-2483.
-
(2006)
J. Biomech
, vol.39
, pp. 2476-2483
-
-
Hopkins, A.R.1
Hansen, U.N.2
Amis, A.A.3
Taylor, M.4
Gronau, N.5
Anglin, C.6
-
47
-
-
85040875608
-
-
Cambridge University Press, Cambridge, UK
-
Johnson, K. L., 1985, Contact Mechanics, Cambridge University Press, Cambridge, UK.
-
(1985)
Contact Mechanics
-
-
Johnson, K.L.1
-
48
-
-
34248185954
-
Conformity and Contact Pressures in Total Shoulder Arthroplasty
-
Toronto, ON, May 29-June 2
-
Friedman, R. J., An, Y. H., and Draughn, R. A., 1996, "Conformity and Contact Pressures in Total Shoulder Arthroplasty," Proceedings of 5th World Biomaterials Conference, Toronto, ON, May 29-June 2.
-
(1996)
Proceedings of 5th World Biomaterials Conference
-
-
Friedman, R.J.1
An, Y.H.2
Draughn, R.A.3
-
49
-
-
0023421211
-
Comparison of the Fatigue Characteristics of Centrifuged and Uncentrifuged Simplex-P Bone Cement
-
Davies, J. P., Burke, D. W., O'Connor, D. O., and Harris, W. H., 1987, "Comparison of the Fatigue Characteristics of Centrifuged and Uncentrifuged Simplex-P Bone Cement," J. Orthop. Res., 5, pp. 366-371.
-
(1987)
J. Orthop. Res
, vol.5
, pp. 366-371
-
-
Davies, J.P.1
Burke, D.W.2
O'Connor, D.O.3
Harris, W.H.4
-
50
-
-
25644438482
-
Finite Element Models of Total Shoulder Replacement: Application of Boundary Conditions
-
Hopkins, A. R., Hansen, U. N., and Amis, A. A., 2005, "Finite Element Models of Total Shoulder Replacement: Application of Boundary Conditions," Comput. Methods Biomech. Biomed. Eng., 8(1), pp. 39-44.
-
(2005)
Comput. Methods Biomech. Biomed. Eng
, vol.8
, Issue.1
, pp. 39-44
-
-
Hopkins, A.R.1
Hansen, U.N.2
Amis, A.A.3
-
51
-
-
0035743211
-
Wear of Polyethylene in Artificial Knee Joints
-
Fisher, J., McEwen, H. M. J., Barnett, P. I., Bell, C. J., Stewart, T. D., Stone, M. H., and Ingham, E., 2001, "Wear of Polyethylene in Artificial Knee Joints," Current Orthopaedics, 15, pp. 399-405.
-
(2001)
Current Orthopaedics
, vol.15
, pp. 399-405
-
-
Fisher, J.1
McEwen, H.M.J.2
Barnett, P.I.3
Bell, C.J.4
Stewart, T.D.5
Stone, M.H.6
Ingham, E.7
-
52
-
-
0004097994
-
-
McGraw-Hill, New York
-
Timoshenko, S. P., and Goodier, J. N., 1970, Theory of Elasticity, McGraw-Hill, New York.
-
(1970)
Theory of Elasticity
-
-
Timoshenko, S.P.1
Goodier, J.N.2
-
53
-
-
0033641706
-
Review of Arm Motion Analyses
-
Anglin, C., and Wyss, U. P., 2000, "Review of Arm Motion Analyses," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 214, pp. 541-555.
-
(2000)
Proc. Inst. Mech. Eng., Part H: J. Eng. Med
, vol.214
, pp. 541-555
-
-
Anglin, C.1
Wyss, U.P.2
-
54
-
-
33846039329
-
Total Shoulder Arthroplasty Simulation Using Finite Element Analysis,
-
Ph.D. thesis, Imperial College, London, UK
-
Hopkins, A. R., 2004, "Total Shoulder Arthroplasty Simulation Using Finite Element Analysis," Ph.D. thesis, Imperial College, London, UK.
-
(2004)
-
-
Hopkins, A.R.1
-
55
-
-
2442759527
-
Effect of Implant Position on Polyethylene Wear in Total Hip Arthroplasty
-
Chicago, IL
-
Robinson, E. J., Devane, P. A., Bourne, P. A., Rorabeck, C. H., and Hardie, R., 1995, "Effect of Implant Position on Polyethylene Wear in Total Hip Arthroplasty," Proceedings of Annual Meeting of the American Academy of Orthopaedic Surgeons, Chicago, IL.
-
(1995)
Proceedings of Annual Meeting of the American Academy of Orthopaedic Surgeons
-
-
Robinson, E.J.1
Devane, P.A.2
Bourne, P.A.3
Rorabeck, C.H.4
Hardie, R.5
-
56
-
-
0029892254
-
Polyethylene Wear in Scanhip(R) Arthroplasty with a 22 or 32 mm Head - 62 Matched Patients Followed for 7-9 Years
-
Kesteris, U., Ilchmann, T., Wingstrand, H., and Onnerfalt, R., 1996, "Polyethylene Wear in Scanhip(R) Arthroplasty with a 22 or 32 mm Head - 62 Matched Patients Followed for 7-9 Years," Acta Orthop. Scand., 67, pp. 125-127.
-
(1996)
Acta Orthop. Scand
, vol.67
, pp. 125-127
-
-
Kesteris, U.1
Ilchmann, T.2
Wingstrand, H.3
Onnerfalt, R.4
-
57
-
-
0030746652
-
Radiographic Evaluation of Penetration by the Femoral Head into the Polyethylene Liner Over Time
-
Sychterz, C. J., Engh, C. A., Shah, N., and Engh, C. A., 1997, "Radiographic Evaluation of Penetration by the Femoral Head into the Polyethylene Liner Over Time," J. Bone Joint Surg. Br., 79A, pp. 1040-1046.
-
(1997)
J. Bone Joint Surg. Br
, vol.79 A
, pp. 1040-1046
-
-
Sychterz, C.J.1
Engh, C.A.2
Shah, N.3
Engh, C.A.4
-
58
-
-
0032801070
-
Simulation of Initial Frontside and Backside Wear Rates in a Modular Acetabular Component with Multiple Screw Holes
-
Kurtz, S. M., Ochoa, J. A., Hovey, C. B., and White, C. V., 1999, "Simulation of Initial Frontside and Backside Wear Rates in a Modular Acetabular Component with Multiple Screw Holes," J. Biomech., 32, pp. 967-976.
-
(1999)
J. Biomech
, vol.32
, pp. 967-976
-
-
Kurtz, S.M.1
Ochoa, J.A.2
Hovey, C.B.3
White, C.V.4
|