Defibrillator implantation without induction of ventricular fibrillation: Good enough?

Author keywords

Arrhythmia; Cardioversion; Defibrillation; Editorials; Fibrillation; Heart arrest; Tachyarrhythmias

Indexed keywords

CARDIOVASCULAR RISK; CLINICAL PRACTICE; DEFIBRILLATION; DEFIBRILLATOR; EDITORIAL; ELECTROCARDIOGRAPHY; HEART ARRHYTHMIA; HEART FAILURE; HEART VENTRICLE FIBRILLATION; HUMAN; IMPLANTATION; PATIENT SAFETY; PRIORITY JOURNAL; TACHYCARDIA;

EID: 34248167637     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/CIRCULATIONAHA.107.698548     Document Type: Editorial
Times cited : (2)

References (5)
  • 1
    • 33644670547 scopus 로고    scopus 로고
    • The defibrillation safety margin of patients receiving ICDs: A matter of definition
    • Barold SS, Herweg B, Curtis AB. The defibrillation safety margin of patients receiving ICDs: a matter of definition. Pacing Clin Electrophysiol. 2005;28:881-882.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 881-882
    • Barold, S.S.1    Herweg, B.2    Curtis, A.B.3
  • 3
    • 34248162434 scopus 로고    scopus 로고
    • Day JD, Doshi RN, Belott P, Birgersdotter-Green U, Behboodikhah M, Ott P, Glatter KA, Tobias S, Frumin H, Lee BK, Merillat J, Wiener I, Wang S, Grogin H, Chun S, Patrawalla R, Crandall B, Osborn JS, Weiss JP, Lappe DL, Neuman S. Inductionless or limited shock testing is possible in most patients with implantable cardioverter-defibrillators/ cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations). Circulation. 2007;115:2382-2389.
    • Day JD, Doshi RN, Belott P, Birgersdotter-Green U, Behboodikhah M, Ott P, Glatter KA, Tobias S, Frumin H, Lee BK, Merillat J, Wiener I, Wang S, Grogin H, Chun S, Patrawalla R, Crandall B, Osborn JS, Weiss JP, Lappe DL, Neuman S. Inductionless or limited shock testing is possible in most patients with implantable cardioverter-defibrillators/ cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations). Circulation. 2007;115:2382-2389.
  • 4
    • 0037251180 scopus 로고    scopus 로고
    • Safety of a single successful conversion of ventricular fibrillation before the implantation of cardioverter defibrillators
    • Gold MR, Breiter D, Leman R, Eric JR, Shorofsky SR, Hahn SJ. Safety of a single successful conversion of ventricular fibrillation before the implantation of cardioverter defibrillators. Pacing Clin Electrophysiol. 2003;26:483-486.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 483-486
    • Gold, M.R.1    Breiter, D.2    Leman, R.3    Eric, J.R.4    Shorofsky, S.R.5    Hahn, S.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.