메뉴 건너뛰기




Volumn 365, Issue 2, 2007, Pages 222-229

An ImmunoChip prototype for simultaneous detection of antiepileptic drugs using an enhanced one-step homogeneous immunoassay

Author keywords

Antiepileptic drugs; Bioluminescence; CEDIA; Homogeneous immunoassay; ImmunoChip; Therapeutic drug monitoring

Indexed keywords

AMIDES; BIOLUMINESCENCE; CHARGE COUPLED DEVICES; CLONING; METABOLITES; PATIENT MONITORING; REAGENTS;

EID: 34247866237     PISSN: 00032697     EISSN: 10960309     Source Type: Journal    
DOI: 10.1016/j.ab.2007.03.019     Document Type: Article
Times cited : (12)

References (19)
  • 2
    • 0034622925 scopus 로고    scopus 로고
    • Printing proteins as microarrays for high-throughput function determination
    • MacBeath G., and Schreiber S.L. Printing proteins as microarrays for high-throughput function determination. Science 289 (2000) 1760-1763
    • (2000) Science , vol.289 , pp. 1760-1763
    • MacBeath, G.1    Schreiber, S.L.2
  • 3
    • 0242585369 scopus 로고    scopus 로고
    • Personal sensors for the diagnosis and management of metabolic disorders
    • Davies R., Bartholomeusz D.A., and Andrade J.D. Personal sensors for the diagnosis and management of metabolic disorders. IEEE Eng. Med. Biol. Mag. 22 (2003) 32-42
    • (2003) IEEE Eng. Med. Biol. Mag. , vol.22 , pp. 32-42
    • Davies, R.1    Bartholomeusz, D.A.2    Andrade, J.D.3
  • 4
    • 33646205505 scopus 로고    scopus 로고
    • J.D. Andrade, D.A. Bartholomeusz, R. Davies, X. Yang, J. Janatova, Multi-analyte bioluminescence-based disposable ChemChips for home-based applications: Update, in: G.E. Cohn, W.S. Grundfest, D.A. Benaron, T. Vo-Dinh (Eds.), Advanced Biomedical and Clinical Diagnostic Systems IV, Proceedings of SPIE, vol. 6080, 2006, 60800W.
  • 6
    • 4444380324 scopus 로고    scopus 로고
    • Modeling of homogeneous cloned enzyme donor immunoassay
    • Jeon S.I., Yang X., and Andrade J.D. Modeling of homogeneous cloned enzyme donor immunoassay. Anal. Biochem. 333 (2004) 136-147
    • (2004) Anal. Biochem. , vol.333 , pp. 136-147
    • Jeon, S.I.1    Yang, X.2    Andrade, J.D.3
  • 7
    • 9944247052 scopus 로고    scopus 로고
    • Homogeneous enzyme immunoassay modified for application to luminescence-based biosensors
    • Yang X., Janatova J., and Andrade J.D. Homogeneous enzyme immunoassay modified for application to luminescence-based biosensors. Anal. Biochem. 336 (2005) 102-107
    • (2005) Anal. Biochem. , vol.336 , pp. 102-107
    • Yang, X.1    Janatova, J.2    Andrade, J.D.3
  • 8
    • 0027027361 scopus 로고
    • A new ultrasensitive bioluminogenic enzyme substrate for β-galactosidase
    • Geiger R., Schneider E., Wallenfels K., and Miska W. A new ultrasensitive bioluminogenic enzyme substrate for β-galactosidase. Biol. Chem. Hoppe-Seyler 373 (1992) 1187-1191
    • (1992) Biol. Chem. Hoppe-Seyler , vol.373 , pp. 1187-1191
    • Geiger, R.1    Schneider, E.2    Wallenfels, K.3    Miska, W.4
  • 9
    • 0036001240 scopus 로고    scopus 로고
    • Evaluation of fluorescence polarization assays for measuring valproic acid, phenytoin, carbamazepine, and phenobarbital in serum
    • Steijns L.S., Bouw J., and van der Weide J. Evaluation of fluorescence polarization assays for measuring valproic acid, phenytoin, carbamazepine, and phenobarbital in serum. Ther. Drug Monit. 24 (2002) 432-435
    • (2002) Ther. Drug Monit. , vol.24 , pp. 432-435
    • Steijns, L.S.1    Bouw, J.2    van der Weide, J.3
  • 11
    • 34247869940 scopus 로고    scopus 로고
    • D.A. Bartholomeusz, Development of a bioluminescence-based multianalyte biosensor: Fabrication and instrumentation, Ph.D. thesis, University of Utah, 2006.
  • 13
    • 0014827695 scopus 로고
    • Quantitative estimation of diphenylhydantoin, primidone, and phenobarbital in plasma by gas-liquid chromatography
    • Kupferberg H.J. Quantitative estimation of diphenylhydantoin, primidone, and phenobarbital in plasma by gas-liquid chromatography. Clin. Chim. Acta 29 (1970) 282-288
    • (1970) Clin. Chim. Acta , vol.29 , pp. 282-288
    • Kupferberg, H.J.1
  • 14
    • 23444451266 scopus 로고    scopus 로고
    • Simultaneous determination of lamotrigine, phenobarbitone, carbamazepine, and phenytoin in human serum by high-performance liquid chromatography
    • Patil K.M., and Bodhankar S.L. Simultaneous determination of lamotrigine, phenobarbitone, carbamazepine, and phenytoin in human serum by high-performance liquid chromatography. J. Pharm. Biomed. Anal. 39 (2005) 181-186
    • (2005) J. Pharm. Biomed. Anal. , vol.39 , pp. 181-186
    • Patil, K.M.1    Bodhankar, S.L.2
  • 15
    • 0017186566 scopus 로고
    • Radioimmunoassay, enzyme immunoassay, spectrophotometry, and gas-liquid chromatography compared for determination of phenobarbital and diphenylhydantoin
    • Spiehler V., Sun L., Miyada D.S., Sarandis S.G., Walwick E.R., Klein M.W., Jordan D.B., and Jessen B. Radioimmunoassay, enzyme immunoassay, spectrophotometry, and gas-liquid chromatography compared for determination of phenobarbital and diphenylhydantoin. Clin. Chem. 22 (1976) 749-753
    • (1976) Clin. Chem. , vol.22 , pp. 749-753
    • Spiehler, V.1    Sun, L.2    Miyada, D.S.3    Sarandis, S.G.4    Walwick, E.R.5    Klein, M.W.6    Jordan, D.B.7    Jessen, B.8
  • 17
    • 13844299569 scopus 로고    scopus 로고
    • Liquid chromatography-mass spectrometry in forensic and clinical toxicology
    • Maurer H.H. Liquid chromatography-mass spectrometry in forensic and clinical toxicology. Anal. Bioanal. Chem. 381 (2005) 110-118
    • (2005) Anal. Bioanal. Chem. , vol.381 , pp. 110-118
    • Maurer, H.H.1
  • 18
    • 0025756128 scopus 로고
    • Current issues in the treatment of epilepsy
    • Pugh C.B., and Garnett W.R. Current issues in the treatment of epilepsy. Clin. Pharmacol. 10 (1991) 335-358
    • (1991) Clin. Pharmacol. , vol.10 , pp. 335-358
    • Pugh, C.B.1    Garnett, W.R.2
  • 19
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.