메뉴 건너뛰기




Volumn 14, Issue 7, 2007, Pages 1346-1350

Premature fracture of a stainless steel 316L orthopaedic plate implant by alternative episodes of fatigue and cleavage decoherence

Author keywords

Cleavage; Failure; Fatigue striations; Orthopaedic support plate; SS 316L

Indexed keywords

CYCLIC LOADS; FAILURE ANALYSIS; FATIGUE OF MATERIALS; FRACTURE; IMPLANTS (SURGICAL); MORPHOLOGY; ORTHOPEDICS; TOPOGRAPHY;

EID: 34247633042     PISSN: 13506307     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.engfailanal.2006.11.010     Document Type: Article
Times cited : (38)

References (8)
  • 1
    • 0010542565 scopus 로고
    • ASM International: The Materials Information Society p. 670-94
    • Pohler O.E.M. Failures of Metallic Orthopedic Implants. ASM Handbook. Failure analysis and prevention vol. 11 (1995), ASM International: The Materials Information Society p. 670-94
    • (1995) Failure analysis and prevention , vol.11
    • Pohler, O.E.M.1
  • 2
    • 33846299184 scopus 로고
    • ASM International: The Materials Information Society p.12-71
    • Kerlins V. Modes of Fracture, ASM Handbook. Fractography vol. 12 (1995), ASM International: The Materials Information Society p.12-71
    • (1995) Fractography , vol.12
    • Kerlins, V.1
  • 4
    • 0036901151 scopus 로고    scopus 로고
    • Failure Analysis of surgical implants in Brazil
    • Azevedo C.R.F., and Hippert Jr. E. Failure Analysis of surgical implants in Brazil. Eng Fail An 9 (2002) 621-633
    • (2002) Eng Fail An , vol.9 , pp. 621-633
    • Azevedo, C.R.F.1    Hippert Jr., E.2
  • 5
    • 12444293868 scopus 로고    scopus 로고
    • Metallurgical investigation of a failure in 316L stainless steel orthopaedic implant
    • Sudhakar K.V. Metallurgical investigation of a failure in 316L stainless steel orthopaedic implant. Eng Fail An 12 (2005) 249-256
    • (2005) Eng Fail An , vol.12 , pp. 249-256
    • Sudhakar, K.V.1
  • 6
    • 0028312716 scopus 로고
    • Investigation of failures in stainless steel orthopaedic implant devices: fatigue failure due to improper fixation of a compression bone plate
    • Sivakumar M., Kamachi Mudali U., and Rajeswari S. Investigation of failures in stainless steel orthopaedic implant devices: fatigue failure due to improper fixation of a compression bone plate. Mat Sci Lett 13 (1994) 142-145
    • (1994) Mat Sci Lett , vol.13 , pp. 142-145
    • Sivakumar, M.1    Kamachi Mudali, U.2    Rajeswari, S.3
  • 7
    • 0027540171 scopus 로고
    • Investigation of biomechanically induced fatigue failure of a stainless steel orthopaedic implant device
    • Sivakumar M., and Rajeswari S. Investigation of biomechanically induced fatigue failure of a stainless steel orthopaedic implant device. Mat Sci Lett 12 (1993) 145-148
    • (1993) Mat Sci Lett , vol.12 , pp. 145-148
    • Sivakumar, M.1    Rajeswari, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.