메뉴 건너뛰기




Volumn 221, Issue 3, 2007, Pages 291-303

An analysis of the in vivo deterioration of Co-Cr-Mo implants through wear and corrosion

Author keywords

Co Cr Mo alloy; Corrosion; Hip prosthesis; Wear

Indexed keywords

BONE CEMENT; CORROSION; HIP PROSTHESES; IMPLANTS (SURGICAL); INTERFACES (MATERIALS); POLYMETHYL METHACRYLATES; WEAR OF MATERIALS;

EID: 34247615544     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM208     Document Type: Article
Times cited : (30)

References (59)
  • 1
    • 0005059996 scopus 로고
    • The properties and clinical uses of cobalt-chromium alloys
    • Ed. D. E Williams, CRC Press, Boca Raton, Florida
    • Williams, D. F. The properties and clinical uses of cobalt-chromium alloys. In Biocompatibility of clinical implant materials (Ed. D. E Williams), Vol. 1, 1981, pp. 96-126 (CRC Press, Boca Raton, Florida).
    • (1981) Biocompatibility of clinical implant materials , vol.1 , pp. 96-126
    • Williams, D.F.1
  • 2
    • 0013093214 scopus 로고
    • Corrosion of metallic implants and prosthetic devices
    • Ed. L. J. Korb, 9th edition, ASM International, Metals Park, Ohio
    • Fraker, A. C. Corrosion of metallic implants and prosthetic devices. In Corrosion - metals handbook (Ed. L. J. Korb), Vol. 13, 9th edition, 1987, pp. 1324-1335 (ASM International, Metals Park, Ohio).
    • (1987) Corrosion - metals handbook , vol.13 , pp. 1324-1335
    • Fraker, A.C.1
  • 3
    • 0006754793 scopus 로고
    • Corrosion of cobalt-base alloys
    • Ed. L. J. Korb, 9th edition, ASM International, Metals Park, Ohio
    • Crook, P. Corrosion of cobalt-base alloys. In Corrosion - metals handbook (Ed. L. J. Korb), Vol. 13, 9th edition, 1987, pp. 658-668 (ASM International, Metals Park, Ohio).
    • (1987) Corrosion - metals handbook , vol.13 , pp. 658-668
    • Crook, P.1
  • 4
    • 0028666258 scopus 로고
    • Corrosion and other electrochemical aspects of biomaterials
    • Bundy, K. J. Corrosion and other electrochemical aspects of biomaterials. Crit. Rev. Biomed. Engng, 1994, 22, 139-251.
    • (1994) Crit. Rev. Biomed. Engng , vol.22 , pp. 139-251
    • Bundy, K.J.1
  • 5
    • 0023384583 scopus 로고
    • The electrochemical behavior of metallic implant materials as an indicator of their biocompatibility
    • Zitter, H. and Plenk, H. Jr The electrochemical behavior of metallic implant materials as an indicator of their biocompatibility. J. Biomed Mater Res., 1987, 21, 881-896.
    • (1987) J. Biomed Mater Res , vol.21 , pp. 881-896
    • Zitter, H.1    Plenk Jr, H.2
  • 6
    • 0018739369 scopus 로고
    • Fundamental aspects of the corrosion of metallic implants
    • Eds B. C. Syrrett and A. Acharya, ASTM International, Philadelphia, Pennsylvania
    • Kruger, J. Fundamental aspects of the corrosion of metallic implants. In Corrosion and degradation of implant materials, ASM STP 684 (Eds B. C. Syrrett and A. Acharya), 1979, pp. 107-127 (ASTM International, Philadelphia, Pennsylvania).
    • (1979) Corrosion and degradation of implant materials, ASM STP 684 , pp. 107-127
    • Kruger, J.1
  • 7
    • 0017417211 scopus 로고
    • Corrosion behaviour of cast and forged implant materials for artificial joints, particularly with respect to compound design
    • Süry, P. Corrosion behaviour of cast and forged implant materials for artificial joints, particularly with respect to compound design. Corros. Sci., 1977, 17, 155-169.
    • (1977) Corros. Sci , vol.17 , pp. 155-169
    • Süry, P.1
  • 8
    • 0018011075 scopus 로고
    • Corrosion behaviour of cast and forged cobalt-based alloys for double-alloy joint endoprostheses
    • Süry, P. and Semlitsch, M. Corrosion behaviour of cast and forged cobalt-based alloys for double-alloy joint endoprostheses. J. Biomed. Mater Res., 1977, 12, 723-741.
    • (1977) J. Biomed. Mater Res , vol.12 , pp. 723-741
    • Süry, P.1    Semlitsch, M.2
  • 9
    • 0009912212 scopus 로고    scopus 로고
    • Goldberg, J. R., Buckley, C. A., Jacobs, J. J., and Gilbert, J. L. Corrosion testing of modular hip implants. In Modularity of orthopedic implants (Eds D. E. Marlowe, J. E. Parr, and M. B. Mayor), ASTM STP 1301, 1997, pp. 157-176 (ASTM International, Philadelphia, Pennsylvania).
    • Goldberg, J. R., Buckley, C. A., Jacobs, J. J., and Gilbert, J. L. Corrosion testing of modular hip implants. In Modularity of orthopedic implants (Eds D. E. Marlowe, J. E. Parr, and M. B. Mayor), ASTM STP 1301, 1997, pp. 157-176 (ASTM International, Philadelphia, Pennsylvania).
  • 10
    • 0016127928 scopus 로고
    • Couple corrosion among alloys for skeletal prostheses
    • Rostoker, W. and Pretzel, C. W. Couple corrosion among alloys for skeletal prostheses. J. Biomed. Mater Res., 1974, 8, 407-419.
    • (1974) J. Biomed. Mater Res , vol.8 , pp. 407-419
    • Rostoker, W.1    Pretzel, C.W.2
  • 12
    • 0031555492 scopus 로고    scopus 로고
    • Electrochemical response of CoCrMo to high speed fracture of its metal oxide using an electrochemical scratch test method
    • Goldberg, J. R. and Gilbert, J. L., Electrochemical response of CoCrMo to high speed fracture of its metal oxide using an electrochemical scratch test method. J. Biomed. Mater Res., 1997, 37, 421-431.
    • (1997) J. Biomed. Mater Res , vol.37 , pp. 421-431
    • Goldberg, J.R.1    Gilbert, J.L.2
  • 13
    • 0030810504 scopus 로고    scopus 로고
    • Friction in hip prostheses
    • Hall, R. M. and Unsworth, A. Friction in hip prostheses. Biomaterials, 1997, 18, 1017-1026.
    • (1997) Biomaterials , vol.18 , pp. 1017-1026
    • Hall, R.M.1    Unsworth, A.2
  • 14
  • 15
    • 0034004913 scopus 로고    scopus 로고
    • Electrochemical modelling of passivation phenomena in tribocorrosion
    • Jemmely, P., Mischler, S., and Landolt, D. Electrochemical modelling of passivation phenomena in tribocorrosion. Wear, 2000, 237, 63-76.
    • (2000) Wear , vol.237 , pp. 63-76
    • Jemmely, P.1    Mischler, S.2    Landolt, D.3
  • 16
    • 0032026338 scopus 로고    scopus 로고
    • Wear accelerated corrosion of passive metals in tribocorrosion systems
    • Mischler, S., Debaud, S., and Landolt, D. Wear accelerated corrosion of passive metals in tribocorrosion systems. J. Electrochem. Soc., 1998, 145, 750-758.
    • (1998) J. Electrochem. Soc , vol.145 , pp. 750-758
    • Mischler, S.1    Debaud, S.2    Landolt, D.3
  • 17
    • 0027068507 scopus 로고    scopus 로고
    • Kovacs, R, Davidson, J. A., and Daigle, K. Correlation between the metal ion concentration and the fretting waer of orthopaedic implant metals. In Particulate debris ftom medical implants: mechanisms of formation and biological consequences, ASTM STP 1144 (Ed. K. R. St John), 1992, pp. 160-176 (ASTM, Philadelphia, Pennsylvania).
    • Kovacs, R, Davidson, J. A., and Daigle, K. Correlation between the metal ion concentration and the fretting waer volume of orthopaedic implant metals. In Particulate debris ftom medical implants: mechanisms of formation and biological consequences, ASTM STP 1144 (Ed. K. R. St John), 1992, pp. 160-176 (ASTM, Philadelphia, Pennsylvania).
  • 18
    • 0021322281 scopus 로고
    • Systemic effects of biomaterials
    • Black, J. Systemic effects of biomaterials. Biomaterials, 1984, 5, 11-18.
    • (1984) Biomaterials , vol.5 , pp. 11-18
    • Black, J.1
  • 19
    • 0035256195 scopus 로고    scopus 로고
    • In vitro reaction to orthopaedic biomaterials by macrophages and lymphocytes isolated from patients undergoing revision surgery
    • Trinidade, M. C. D., Lind, M., Sun, D., Schurman, D. J., Goodman, S. B., and Smith, R. L. In vitro reaction to orthopaedic biomaterials by macrophages and lymphocytes isolated from patients undergoing revision surgery. Biomaterials, 2000, 22, 253-259.
    • (2000) Biomaterials , vol.22 , pp. 253-259
    • Trinidade, M.C.D.1    Lind, M.2    Sun, D.3    Schurman, D.J.4    Goodman, S.B.5    Smith, R.L.6
  • 20
    • 0033814142 scopus 로고    scopus 로고
    • A triple assay technique for the evaluation of metal induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty
    • Hallab, N. J., Mikeca, K., and Jacobs, J. J. A triple assay technique for the evaluation of metal induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty. J. Biomed. Mater Res., 2000, 53, 480-489.
    • (2000) J. Biomed. Mater Res , vol.53 , pp. 480-489
    • Hallab, N.J.1    Mikeca, K.2    Jacobs, J.J.3
  • 21
    • 0028533512 scopus 로고
    • Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements
    • Yang, J. and Merritt K. Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements. J. Biomed. Mater Res., 1994, 28, 1249-1258.
    • (1994) J. Biomed. Mater Res , vol.28 , pp. 1249-1258
    • Yang, J.1    Merritt, K.2
  • 22
    • 0030150670 scopus 로고    scopus 로고
    • Effects of Co-Cr corrosion products and corresponding separate metal ions on human osteoblast-like cell cultures
    • Tomás, H., Carvalho, G. S., Fernandes, M. H. Freire, A. P., and Abrantes, I. M. Effects of Co-Cr corrosion products and corresponding separate metal ions on human osteoblast-like cell cultures. J. Mater. Sci. Mater. Medicine, 1996, 7, 291-296.
    • (1996) J. Mater. Sci. Mater. Medicine , vol.7 , pp. 291-296
    • Tomás, H.1    Carvalho, G.S.2    Fernandes, M.H.3    Freire, A.P.4    Abrantes, I.M.5
  • 23
    • 0029837640 scopus 로고    scopus 로고
    • Biologic effects of cobalt chrome in cell and animal models
    • Howie, D. W., Rogers, S. D., McGee, M. A., and Haynes, D. R. Biologic effects of cobalt chrome in cell and animal models. Clin. Orthop. Related Res., 1996, 329, Suppl., S217-S232.
    • (1996) Clin. Orthop. Related Res , vol.329 , Issue.SUPPL.
    • Howie, D.W.1    Rogers, S.D.2    McGee, M.A.3    Haynes, D.R.4
  • 25
    • 0031051493 scopus 로고    scopus 로고
    • Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements
    • Lee, S. H., Brennan, E R., Jacobs, J. J., Urban, R. M., Ragasa, D. R., and Giant, T. T. Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements. J. Orthop. Res., 1997, 5, 40-49.
    • (1997) J. Orthop. Res , vol.5 , pp. 40-49
    • Lee, S.H.1    Brennan, E.R.2    Jacobs, J.J.3    Urban, R.M.4    Ragasa, D.R.5    Giant, T.T.6
  • 26
    • 0031844665 scopus 로고    scopus 로고
    • Migration, particles, and fluid pressure. A discussion of causes of prosthetic loosening
    • Aspenberg, P., and Van der Vis, H. Migration, particles, and fluid pressure. A discussion of causes of prosthetic loosening. Clin. Orthop. Related Res., 1998, 352, 75-80.
    • (1998) Clin. Orthop. Related Res , vol.352 , pp. 75-80
    • Aspenberg, P.1    Van der Vis, H.2
  • 27
    • 0028501851 scopus 로고    scopus 로고
    • Blumenthal, N. C., Cosma, V., Jaffe, W., and Stuchin, S. A new technique for quantitation of metal particulates and metal reaction products in tissues near implants. J. Appl. Biomaterials, 1994, 5(3), 191-193.
    • Blumenthal, N. C., Cosma, V., Jaffe, W., and Stuchin, S. A new technique for quantitation of metal particulates and metal reaction products in tissues near implants. J. Appl. Biomaterials, 1994, 5(3), 191-193.
  • 29
    • 0028245867 scopus 로고
    • Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
    • Huk, O. L., Bansal, M., Betts, E, Rimnac, C. M., Lieberman, J. R., Huo, M. H., and Salvati, E. A. Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J. Bone Jt Surg., 1994, 76B(4), 568-574.
    • (1994) J. Bone Jt Surg , vol.76 B , Issue.4 , pp. 568-574
    • Huk, O.L.1    Bansal, M.2    Betts, E.3    Rimnac, C.M.4    Lieberman, J.R.5    Huo, M.H.6    Salvati, E.A.7
  • 31
    • 0028073911 scopus 로고
    • Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings
    • Urban, R. M., Jacobs, J. J., Gilbert, J. L., and Galante, J. O. Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. J. Bone Jt Surg., 1994, 76A(9), 1345-1359.
    • (1994) J. Bone Jt Surg , vol.76 A , Issue.9 , pp. 1345-1359
    • Urban, R.M.1    Jacobs, J.J.2    Gilbert, J.L.3    Galante, J.O.4
  • 32
    • 0025328955 scopus 로고
    • Biochemical and histological evaluation of the synovial-like tissue around failed (loose) total joint replacement prostheses in human subjects and a canine model
    • Thornhill, T. S., Ozuna, R. M., Shortkroff, S., Keller, YL, Sledge, C. B., and Spector, M. Biochemical and histological evaluation of the synovial-like tissue around failed (loose) total joint replacement prostheses in human subjects and a canine model. Biomaterials, 1990, 11, 69-72.
    • (1990) Biomaterials , vol.11 , pp. 69-72
    • Thornhill, T.S.1    Ozuna, R.M.2    Shortkroff, S.3    Keller, Y.L.4    Sledge, C.B.5    Spector, M.6
  • 33
    • 0028349883 scopus 로고
    • Size and shape of biomaterial wear debris
    • Savio, J. A. III, Overcamp, L. M., and Black, J. Size and shape of biomaterial wear debris. Clin. Mater., 1994, 15, 101-147.
    • (1994) Clin. Mater , vol.15 , pp. 101-147
    • Savio III, J.A.1    Overcamp, L.M.2    Black, J.3
  • 34
    • 23044531608 scopus 로고    scopus 로고
    • El-Warrak, A. O., Olmstead, M. L., von Rechenberg, B., and Auer, J. A. A review of aseptic loosening in total hip arthroplasty. Vet. Comp. Orthop. Traumatology, 2002, 14(3), 115-124.
    • El-Warrak, A. O., Olmstead, M. L., von Rechenberg, B., and Auer, J. A. A review of aseptic loosening in total hip arthroplasty. Vet. Comp. Orthop. Traumatology, 2002, 14(3), 115-124.
  • 35
    • 0020576705 scopus 로고
    • The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis
    • Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., O'Neil, D. A., and Harris, W. H. The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. J. Bone Jt Surg., 1983, 65A, 575-584.
    • (1983) J. Bone Jt Surg , vol.65 A , pp. 575-584
    • Goldring, S.R.1    Schiller, A.L.2    Roelke, M.3    Rourke, C.M.4    O'Neil, D.A.5    Harris, W.H.6
  • 38
    • 0029045786 scopus 로고
    • Mechanisms of cellular recruitment in aseptic loosening of prosthetic joint implants
    • Horowitz, S. M. and Purdon, M. A. Mechanisms of cellular recruitment in aseptic loosening of prosthetic joint implants. Calcified Tissue Int., 1995, 57, 301-305.
    • (1995) Calcified Tissue Int , vol.57 , pp. 301-305
    • Horowitz, S.M.1    Purdon, M.A.2
  • 39
    • 0027326202 scopus 로고
    • Production of cytokins around loosened cemented acetabular components; analysis with immunohistochemical techniques and in situ hybridisation
    • Jiranek, W. A., Machando, M., Jasty, M., Jevsevar, D., Wolle, H. J., and Goldring, S. R. Production of cytokins around loosened cemented acetabular components; analysis with immunohistochemical techniques and in situ hybridisation. J. Bone Jt Surg., 1993, 75A, 863-879.
    • (1993) J. Bone Jt Surg , vol.75 A , pp. 863-879
    • Jiranek, W.A.1    Machando, M.2    Jasty, M.3    Jevsevar, D.4    Wolle, H.J.5    Goldring, S.R.6
  • 40
    • 0031745101 scopus 로고    scopus 로고
    • Cellular profile and cytokine production at prosthetic interfaces; Study of tissues retrieved from revised hip and knee replacements
    • Goodman, S. B., Huie, P, Song, Y., Schurman, D., Maloney, W., and Woolson, S. Cellular profile and cytokine production at prosthetic interfaces; Study of tissues retrieved from revised hip and knee replacements. J. Bone Jt Surg., 1998, 80B, 531-539.
    • (1998) J. Bone Jt Surg , vol.80 B , pp. 531-539
    • Goodman, S.B.1    Huie, P.2    Song, Y.3    Schurman, D.4    Maloney, W.5    Woolson, S.6
  • 43
    • 0031938258 scopus 로고    scopus 로고
    • Wear and osteolysis in total joint replacements
    • Kadoya, Y., Kobayashi, A., and Ohashi, H. Wear and osteolysis in total joint replacements. Acta Orthop. Scand., 1998, 278, Suppl., 1-16.
    • (1998) Acta Orthop. Scand , vol.278 , Issue.SUPPL. , pp. 1-16
    • Kadoya, Y.1    Kobayashi, A.2    Ohashi, H.3
  • 44
    • 0028034860 scopus 로고
    • Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses
    • Karrholm, J., Borssen, B., Lowenhielm, G., and Snorrason, F., Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J. Bone Jt Surg., 1994, 76B, 912-917.
    • (1994) J. Bone Jt Surg , vol.76 B , pp. 912-917
    • Karrholm, J.1    Borssen, B.2    Lowenhielm, G.3    Snorrason, F.4
  • 45
    • 0029363397 scopus 로고
    • Canine cemented total hip replacements: State of the art
    • Olmstead, M. L. Canine cemented total hip replacements: state of the art. J. Small Anim. Practice, 1995, 36(9), 395-399.
    • (1995) J. Small Anim. Practice , vol.36 , Issue.9 , pp. 395-399
    • Olmstead, M.L.1
  • 47
    • 0033996523 scopus 로고    scopus 로고
    • Correlation between impact strength and fracture toughness of PMMA-based bone cements
    • Lewis, G. and Mdlasi, S. Correlation between impact strength and fracture toughness of PMMA-based bone cements. Biomaterials, 2000, 21, 775-781.
    • (2000) Biomaterials , vol.21 , pp. 775-781
    • Lewis, G.1    Mdlasi, S.2
  • 48
    • 0034040792 scopus 로고    scopus 로고
    • Effects of fatigue loading and PMMA precoating on the adhesion and subcritical debonding of prosthetic-PMMA interfaces
    • Ohashi, K, L. and Dauskardt, R. H. Effects of fatigue loading and PMMA precoating on the adhesion and subcritical debonding of prosthetic-PMMA interfaces. J. Biomed. Mater Res., 2000, 51, 172-183.
    • (2000) J. Biomed. Mater Res , vol.51 , pp. 172-183
    • Ohashi, K.L.1    Dauskardt, R.H.2
  • 50
    • 0030506597 scopus 로고    scopus 로고
    • Technique and results for total hip replacement in sheep: An experimental model
    • Bruns, D., Olmstead, M. L., and Litsky, A. Technique and results for total hip replacement in sheep: an experimental model. Vet. Comp. Orthop. Traumatology, 1996, 9, 158-164.
    • (1996) Vet. Comp. Orthop. Traumatology , vol.9 , pp. 158-164
    • Bruns, D.1    Olmstead, M.L.2    Litsky, A.3
  • 52
    • 0032206251 scopus 로고    scopus 로고
    • Variable length scale analysis of surface topography: Characterization of titanium surfaces for biomedical applications
    • Chauvy, P. F., Madore, C., and Landolt, D. Variable length scale analysis of surface topography: characterization of titanium surfaces for biomedical applications. Surf Coatings Technol., 1998, 110, 48-56.
    • (1998) Surf Coatings Technol , vol.110 , pp. 48-56
    • Chauvy, P.F.1    Madore, C.2    Landolt, D.3
  • 53
    • 0002824843 scopus 로고    scopus 로고
    • Surface-enhanced Raman spectroelectrochemical studies of corrosion films on implant Co-Cr-Mo alloy in biosimulating solutions
    • Lip Y.-S., Wang, K., He, P., Huang, B. X., and Kovacs, P. Surface-enhanced Raman spectroelectrochemical studies of corrosion films on implant Co-Cr-Mo alloy in biosimulating solutions. J. Raman Spectrosc., 1999, 30, 97-103.
    • (1999) J. Raman Spectrosc , vol.30 , pp. 97-103
    • Lip, Y.-S.1    Wang, K.2    He, P.3    Huang, B.X.4    Kovacs, P.5
  • 57
    • 0020965469 scopus 로고
    • Serum concentrations of chromium, cobalt and nickel after total hip replacement: A six month study
    • Black, J., Maitin, E. C., Gelman, H., and Morris, D. M. Serum concentrations of chromium, cobalt and nickel after total hip replacement: a six month study. Biomaterials, 1983, 4, 160-164.
    • (1983) Biomaterials , vol.4 , pp. 160-164
    • Black, J.1    Maitin, E.C.2    Gelman, H.3    Morris, D.M.4
  • 58
    • 0029814931 scopus 로고    scopus 로고
    • Distribution of cobalt-chromium wear and corrosion products and biologic reactions
    • Merritt, K. and Brown, S. A. Distribution of cobalt-chromium wear and corrosion products and biologic reactions. Clin. Orthop. Related Res., 1996, 329, Suppl., S233-S243.
    • (1996) Clin. Orthop. Related Res , vol.329 , Issue.SUPPL.
    • Merritt, K.1    Brown, S.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.