1
-
-
0005059996
-
The properties and clinical uses of cobalt-chromium alloys
-
Ed. D. E Williams, CRC Press, Boca Raton, Florida
-
Williams, D. F. The properties and clinical uses of cobalt-chromium alloys. In Biocompatibility of clinical implant materials (Ed. D. E Williams), Vol. 1, 1981, pp. 96-126 (CRC Press, Boca Raton, Florida).
-
(1981)
Biocompatibility of clinical implant materials
, vol.1
, pp. 96-126
-
-
Williams, D.F.1
-
2
-
-
0013093214
-
Corrosion of metallic implants and prosthetic devices
-
Ed. L. J. Korb, 9th edition, ASM International, Metals Park, Ohio
-
Fraker, A. C. Corrosion of metallic implants and prosthetic devices. In Corrosion - metals handbook (Ed. L. J. Korb), Vol. 13, 9th edition, 1987, pp. 1324-1335 (ASM International, Metals Park, Ohio).
-
(1987)
Corrosion - metals handbook
, vol.13
, pp. 1324-1335
-
-
Fraker, A.C.1
-
3
-
-
0006754793
-
Corrosion of cobalt-base alloys
-
Ed. L. J. Korb, 9th edition, ASM International, Metals Park, Ohio
-
Crook, P. Corrosion of cobalt-base alloys. In Corrosion - metals handbook (Ed. L. J. Korb), Vol. 13, 9th edition, 1987, pp. 658-668 (ASM International, Metals Park, Ohio).
-
(1987)
Corrosion - metals handbook
, vol.13
, pp. 658-668
-
-
Crook, P.1
-
4
-
-
0028666258
-
Corrosion and other electrochemical aspects of biomaterials
-
Bundy, K. J. Corrosion and other electrochemical aspects of biomaterials. Crit. Rev. Biomed. Engng, 1994, 22, 139-251.
-
(1994)
Crit. Rev. Biomed. Engng
, vol.22
, pp. 139-251
-
-
Bundy, K.J.1
-
5
-
-
0023384583
-
The electrochemical behavior of metallic implant materials as an indicator of their biocompatibility
-
Zitter, H. and Plenk, H. Jr The electrochemical behavior of metallic implant materials as an indicator of their biocompatibility. J. Biomed Mater Res., 1987, 21, 881-896.
-
(1987)
J. Biomed Mater Res
, vol.21
, pp. 881-896
-
-
Zitter, H.1
Plenk Jr, H.2
-
6
-
-
0018739369
-
Fundamental aspects of the corrosion of metallic implants
-
Eds B. C. Syrrett and A. Acharya, ASTM International, Philadelphia, Pennsylvania
-
Kruger, J. Fundamental aspects of the corrosion of metallic implants. In Corrosion and degradation of implant materials, ASM STP 684 (Eds B. C. Syrrett and A. Acharya), 1979, pp. 107-127 (ASTM International, Philadelphia, Pennsylvania).
-
(1979)
Corrosion and degradation of implant materials, ASM STP 684
, pp. 107-127
-
-
Kruger, J.1
-
7
-
-
0017417211
-
Corrosion behaviour of cast and forged implant materials for artificial joints, particularly with respect to compound design
-
Süry, P. Corrosion behaviour of cast and forged implant materials for artificial joints, particularly with respect to compound design. Corros. Sci., 1977, 17, 155-169.
-
(1977)
Corros. Sci
, vol.17
, pp. 155-169
-
-
Süry, P.1
-
8
-
-
0018011075
-
Corrosion behaviour of cast and forged cobalt-based alloys for double-alloy joint endoprostheses
-
Süry, P. and Semlitsch, M. Corrosion behaviour of cast and forged cobalt-based alloys for double-alloy joint endoprostheses. J. Biomed. Mater Res., 1977, 12, 723-741.
-
(1977)
J. Biomed. Mater Res
, vol.12
, pp. 723-741
-
-
Süry, P.1
Semlitsch, M.2
-
9
-
-
0009912212
-
-
Goldberg, J. R., Buckley, C. A., Jacobs, J. J., and Gilbert, J. L. Corrosion testing of modular hip implants. In Modularity of orthopedic implants (Eds D. E. Marlowe, J. E. Parr, and M. B. Mayor), ASTM STP 1301, 1997, pp. 157-176 (ASTM International, Philadelphia, Pennsylvania).
-
Goldberg, J. R., Buckley, C. A., Jacobs, J. J., and Gilbert, J. L. Corrosion testing of modular hip implants. In Modularity of orthopedic implants (Eds D. E. Marlowe, J. E. Parr, and M. B. Mayor), ASTM STP 1301, 1997, pp. 157-176 (ASTM International, Philadelphia, Pennsylvania).
-
-
-
-
10
-
-
0016127928
-
Couple corrosion among alloys for skeletal prostheses
-
Rostoker, W. and Pretzel, C. W. Couple corrosion among alloys for skeletal prostheses. J. Biomed. Mater Res., 1974, 8, 407-419.
-
(1974)
J. Biomed. Mater Res
, vol.8
, pp. 407-419
-
-
Rostoker, W.1
Pretzel, C.W.2
-
12
-
-
0031555492
-
Electrochemical response of CoCrMo to high speed fracture of its metal oxide using an electrochemical scratch test method
-
Goldberg, J. R. and Gilbert, J. L., Electrochemical response of CoCrMo to high speed fracture of its metal oxide using an electrochemical scratch test method. J. Biomed. Mater Res., 1997, 37, 421-431.
-
(1997)
J. Biomed. Mater Res
, vol.37
, pp. 421-431
-
-
Goldberg, J.R.1
Gilbert, J.L.2
-
13
-
-
0030810504
-
Friction in hip prostheses
-
Hall, R. M. and Unsworth, A. Friction in hip prostheses. Biomaterials, 1997, 18, 1017-1026.
-
(1997)
Biomaterials
, vol.18
, pp. 1017-1026
-
-
Hall, R.M.1
Unsworth, A.2
-
14
-
-
0029276298
-
Methods of measuring wear corrosion synergism
-
Watson, S. M., Friedersdorf, F. J., Madsen, B. W., and Cramer, S. D. Methods of measuring wear corrosion synergism. Wear, 1995, 181, 476-484.
-
(1995)
Wear
, vol.181
, pp. 476-484
-
-
Watson, S.M.1
Friedersdorf, F.J.2
Madsen, B.W.3
Cramer, S.D.4
-
15
-
-
0034004913
-
Electrochemical modelling of passivation phenomena in tribocorrosion
-
Jemmely, P., Mischler, S., and Landolt, D. Electrochemical modelling of passivation phenomena in tribocorrosion. Wear, 2000, 237, 63-76.
-
(2000)
Wear
, vol.237
, pp. 63-76
-
-
Jemmely, P.1
Mischler, S.2
Landolt, D.3
-
16
-
-
0032026338
-
Wear accelerated corrosion of passive metals in tribocorrosion systems
-
Mischler, S., Debaud, S., and Landolt, D. Wear accelerated corrosion of passive metals in tribocorrosion systems. J. Electrochem. Soc., 1998, 145, 750-758.
-
(1998)
J. Electrochem. Soc
, vol.145
, pp. 750-758
-
-
Mischler, S.1
Debaud, S.2
Landolt, D.3
-
17
-
-
0027068507
-
-
Kovacs, R, Davidson, J. A., and Daigle, K. Correlation between the metal ion concentration and the fretting waer of orthopaedic implant metals. In Particulate debris ftom medical implants: mechanisms of formation and biological consequences, ASTM STP 1144 (Ed. K. R. St John), 1992, pp. 160-176 (ASTM, Philadelphia, Pennsylvania).
-
Kovacs, R, Davidson, J. A., and Daigle, K. Correlation between the metal ion concentration and the fretting waer volume of orthopaedic implant metals. In Particulate debris ftom medical implants: mechanisms of formation and biological consequences, ASTM STP 1144 (Ed. K. R. St John), 1992, pp. 160-176 (ASTM, Philadelphia, Pennsylvania).
-
-
-
-
18
-
-
0021322281
-
Systemic effects of biomaterials
-
Black, J. Systemic effects of biomaterials. Biomaterials, 1984, 5, 11-18.
-
(1984)
Biomaterials
, vol.5
, pp. 11-18
-
-
Black, J.1
-
19
-
-
0035256195
-
In vitro reaction to orthopaedic biomaterials by macrophages and lymphocytes isolated from patients undergoing revision surgery
-
Trinidade, M. C. D., Lind, M., Sun, D., Schurman, D. J., Goodman, S. B., and Smith, R. L. In vitro reaction to orthopaedic biomaterials by macrophages and lymphocytes isolated from patients undergoing revision surgery. Biomaterials, 2000, 22, 253-259.
-
(2000)
Biomaterials
, vol.22
, pp. 253-259
-
-
Trinidade, M.C.D.1
Lind, M.2
Sun, D.3
Schurman, D.J.4
Goodman, S.B.5
Smith, R.L.6
-
20
-
-
0033814142
-
A triple assay technique for the evaluation of metal induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty
-
Hallab, N. J., Mikeca, K., and Jacobs, J. J. A triple assay technique for the evaluation of metal induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty. J. Biomed. Mater Res., 2000, 53, 480-489.
-
(2000)
J. Biomed. Mater Res
, vol.53
, pp. 480-489
-
-
Hallab, N.J.1
Mikeca, K.2
Jacobs, J.J.3
-
21
-
-
0028533512
-
Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements
-
Yang, J. and Merritt K. Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements. J. Biomed. Mater Res., 1994, 28, 1249-1258.
-
(1994)
J. Biomed. Mater Res
, vol.28
, pp. 1249-1258
-
-
Yang, J.1
Merritt, K.2
-
22
-
-
0030150670
-
Effects of Co-Cr corrosion products and corresponding separate metal ions on human osteoblast-like cell cultures
-
Tomás, H., Carvalho, G. S., Fernandes, M. H. Freire, A. P., and Abrantes, I. M. Effects of Co-Cr corrosion products and corresponding separate metal ions on human osteoblast-like cell cultures. J. Mater. Sci. Mater. Medicine, 1996, 7, 291-296.
-
(1996)
J. Mater. Sci. Mater. Medicine
, vol.7
, pp. 291-296
-
-
Tomás, H.1
Carvalho, G.S.2
Fernandes, M.H.3
Freire, A.P.4
Abrantes, I.M.5
-
23
-
-
0029837640
-
Biologic effects of cobalt chrome in cell and animal models
-
Howie, D. W., Rogers, S. D., McGee, M. A., and Haynes, D. R. Biologic effects of cobalt chrome in cell and animal models. Clin. Orthop. Related Res., 1996, 329, Suppl., S217-S232.
-
(1996)
Clin. Orthop. Related Res
, vol.329
, Issue.SUPPL.
-
-
Howie, D.W.1
Rogers, S.D.2
McGee, M.A.3
Haynes, D.R.4
-
24
-
-
0031573493
-
Effects of metal ions on white blood cells of patients with failed total joint arthroplasties
-
Savarino, L., Granchi, D., Ciapetti, G., Stea, S., Donati, M. E., Zinghi, G., Fontanesi, G., Rotini, R., and Montanaro, L. Effects of metal ions on white blood cells of patients with failed total joint arthroplasties. J. Biomed. Mater Res., 1999, 47, 543-550.
-
(1999)
J. Biomed. Mater Res
, vol.47
, pp. 543-550
-
-
Savarino, L.1
Granchi, D.2
Ciapetti, G.3
Stea, S.4
Donati, M.E.5
Zinghi, G.6
Fontanesi, G.7
Rotini, R.8
Montanaro, L.9
-
25
-
-
0031051493
-
Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements
-
Lee, S. H., Brennan, E R., Jacobs, J. J., Urban, R. M., Ragasa, D. R., and Giant, T. T. Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements. J. Orthop. Res., 1997, 5, 40-49.
-
(1997)
J. Orthop. Res
, vol.5
, pp. 40-49
-
-
Lee, S.H.1
Brennan, E.R.2
Jacobs, J.J.3
Urban, R.M.4
Ragasa, D.R.5
Giant, T.T.6
-
26
-
-
0031844665
-
Migration, particles, and fluid pressure. A discussion of causes of prosthetic loosening
-
Aspenberg, P., and Van der Vis, H. Migration, particles, and fluid pressure. A discussion of causes of prosthetic loosening. Clin. Orthop. Related Res., 1998, 352, 75-80.
-
(1998)
Clin. Orthop. Related Res
, vol.352
, pp. 75-80
-
-
Aspenberg, P.1
Van der Vis, H.2
-
27
-
-
0028501851
-
-
Blumenthal, N. C., Cosma, V., Jaffe, W., and Stuchin, S. A new technique for quantitation of metal particulates and metal reaction products in tissues near implants. J. Appl. Biomaterials, 1994, 5(3), 191-193.
-
Blumenthal, N. C., Cosma, V., Jaffe, W., and Stuchin, S. A new technique for quantitation of metal particulates and metal reaction products in tissues near implants. J. Appl. Biomaterials, 1994, 5(3), 191-193.
-
-
-
-
28
-
-
0028054956
-
Wear and corrosion of modular interfaces in total hip replacements
-
Cook, S. D., Barrack, R. L., Baffes, G. C., Clemow, A. J., Serekian, P., Dong, N., and Kester, M. A. Wear and corrosion of modular interfaces in total hip replacements. Clin. Orthop. Related Res., 1994, 298, 80-88.
-
(1994)
Clin. Orthop. Related Res
, vol.298
, pp. 80-88
-
-
Cook, S.D.1
Barrack, R.L.2
Baffes, G.C.3
Clemow, A.J.4
Serekian, P.5
Dong, N.6
Kester, M.A.7
-
29
-
-
0028245867
-
Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
-
Huk, O. L., Bansal, M., Betts, E, Rimnac, C. M., Lieberman, J. R., Huo, M. H., and Salvati, E. A. Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J. Bone Jt Surg., 1994, 76B(4), 568-574.
-
(1994)
J. Bone Jt Surg
, vol.76 B
, Issue.4
, pp. 568-574
-
-
Huk, O.L.1
Bansal, M.2
Betts, E.3
Rimnac, C.M.4
Lieberman, J.R.5
Huo, M.H.6
Salvati, E.A.7
-
30
-
-
0026550544
-
The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy
-
Schmalzried, T. P, Kwong, L. M., Jasty, M., Selacek, R. C., Haire, T. C., O'Connor, D. O., Bragdon, C. R., Kabo, J. M., Malcolm, A. J., Path, M. R. C., and Harris, W. H. The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy. Clin. Orthop. Related Res., 1992, 274, 60-78.
-
(1992)
Clin. Orthop. Related Res
, vol.274
, pp. 60-78
-
-
Schmalzried, T.P.1
Kwong, L.M.2
Jasty, M.3
Selacek, R.C.4
Haire, T.C.5
O'Connor, D.O.6
Bragdon, C.R.7
Kabo, J.M.8
Malcolm, A.J.9
Path, M.R.C.10
Harris, W.H.11
-
31
-
-
0028073911
-
Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings
-
Urban, R. M., Jacobs, J. J., Gilbert, J. L., and Galante, J. O. Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. J. Bone Jt Surg., 1994, 76A(9), 1345-1359.
-
(1994)
J. Bone Jt Surg
, vol.76 A
, Issue.9
, pp. 1345-1359
-
-
Urban, R.M.1
Jacobs, J.J.2
Gilbert, J.L.3
Galante, J.O.4
-
32
-
-
0025328955
-
Biochemical and histological evaluation of the synovial-like tissue around failed (loose) total joint replacement prostheses in human subjects and a canine model
-
Thornhill, T. S., Ozuna, R. M., Shortkroff, S., Keller, YL, Sledge, C. B., and Spector, M. Biochemical and histological evaluation of the synovial-like tissue around failed (loose) total joint replacement prostheses in human subjects and a canine model. Biomaterials, 1990, 11, 69-72.
-
(1990)
Biomaterials
, vol.11
, pp. 69-72
-
-
Thornhill, T.S.1
Ozuna, R.M.2
Shortkroff, S.3
Keller, Y.L.4
Sledge, C.B.5
Spector, M.6
-
33
-
-
0028349883
-
Size and shape of biomaterial wear debris
-
Savio, J. A. III, Overcamp, L. M., and Black, J. Size and shape of biomaterial wear debris. Clin. Mater., 1994, 15, 101-147.
-
(1994)
Clin. Mater
, vol.15
, pp. 101-147
-
-
Savio III, J.A.1
Overcamp, L.M.2
Black, J.3
-
34
-
-
23044531608
-
-
El-Warrak, A. O., Olmstead, M. L., von Rechenberg, B., and Auer, J. A. A review of aseptic loosening in total hip arthroplasty. Vet. Comp. Orthop. Traumatology, 2002, 14(3), 115-124.
-
El-Warrak, A. O., Olmstead, M. L., von Rechenberg, B., and Auer, J. A. A review of aseptic loosening in total hip arthroplasty. Vet. Comp. Orthop. Traumatology, 2002, 14(3), 115-124.
-
-
-
-
35
-
-
0020576705
-
The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis
-
Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., O'Neil, D. A., and Harris, W. H. The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. J. Bone Jt Surg., 1983, 65A, 575-584.
-
(1983)
J. Bone Jt Surg
, vol.65 A
, pp. 575-584
-
-
Goldring, S.R.1
Schiller, A.L.2
Roelke, M.3
Rourke, C.M.4
O'Neil, D.A.5
Harris, W.H.6
-
36
-
-
0023196425
-
The microscopic anatomy of the bone-cement interface in failed total hip arthroplasties
-
Johanson, N. A., Bullough, P. G., Wilson, P. D. Jr, Salvati, E. A., and Ranawat, C. S. The microscopic anatomy of the bone-cement interface in failed total hip arthroplasties. Clin. Orthop. Related Res., 1987, 218, 643-648.
-
(1987)
Clin. Orthop. Related Res
, vol.218
, pp. 643-648
-
-
Johanson, N.A.1
Bullough, P.G.2
Wilson Jr, P.D.3
Salvati, E.A.4
Ranawat, C.S.5
-
37
-
-
0030442306
-
Tumor necrosis factor-alpha (TNF-alpha) in loosening of total hip replacement (THR)
-
Xu, J. W., Konttinen, Y. T., Lassus, J., Natah, S., Ceponis, A., and Solovieva, S. Tumor necrosis factor-alpha (TNF-alpha) in loosening of total hip replacement (THR). Clin. Expl. Rheumatology, 1996, 14, 643-648.
-
(1996)
Clin. Expl. Rheumatology
, vol.14
, pp. 643-648
-
-
Xu, J.W.1
Konttinen, Y.T.2
Lassus, J.3
Natah, S.4
Ceponis, A.5
Solovieva, S.6
-
38
-
-
0029045786
-
Mechanisms of cellular recruitment in aseptic loosening of prosthetic joint implants
-
Horowitz, S. M. and Purdon, M. A. Mechanisms of cellular recruitment in aseptic loosening of prosthetic joint implants. Calcified Tissue Int., 1995, 57, 301-305.
-
(1995)
Calcified Tissue Int
, vol.57
, pp. 301-305
-
-
Horowitz, S.M.1
Purdon, M.A.2
-
39
-
-
0027326202
-
Production of cytokins around loosened cemented acetabular components; analysis with immunohistochemical techniques and in situ hybridisation
-
Jiranek, W. A., Machando, M., Jasty, M., Jevsevar, D., Wolle, H. J., and Goldring, S. R. Production of cytokins around loosened cemented acetabular components; analysis with immunohistochemical techniques and in situ hybridisation. J. Bone Jt Surg., 1993, 75A, 863-879.
-
(1993)
J. Bone Jt Surg
, vol.75 A
, pp. 863-879
-
-
Jiranek, W.A.1
Machando, M.2
Jasty, M.3
Jevsevar, D.4
Wolle, H.J.5
Goldring, S.R.6
-
40
-
-
0031745101
-
Cellular profile and cytokine production at prosthetic interfaces; Study of tissues retrieved from revised hip and knee replacements
-
Goodman, S. B., Huie, P, Song, Y., Schurman, D., Maloney, W., and Woolson, S. Cellular profile and cytokine production at prosthetic interfaces; Study of tissues retrieved from revised hip and knee replacements. J. Bone Jt Surg., 1998, 80B, 531-539.
-
(1998)
J. Bone Jt Surg
, vol.80 B
, pp. 531-539
-
-
Goodman, S.B.1
Huie, P.2
Song, Y.3
Schurman, D.4
Maloney, W.5
Woolson, S.6
-
41
-
-
0031813777
-
Nitric oxide in local host reaction to total hip replacement
-
Hukkanen, M., Corbett, S. A., Platts, L. A., Konttinen, Y. T., Santavirta, S., and Hughes, S. P. Nitric oxide in local host reaction to total hip replacement. Clin. Orthop. Related Res., 1998, 352, 53-65.
-
(1998)
Clin. Orthop. Related Res
, vol.352
, pp. 53-65
-
-
Hukkanen, M.1
Corbett, S.A.2
Platts, L.A.3
Konttinen, Y.T.4
Santavirta, S.5
Hughes, S.P.6
-
42
-
-
0033151456
-
Cytokine release in mononuclear cells of patients with Co-Cr hip prosthesis
-
Granchi, D,. Ciapetti, G., Stea, S., Savarino, L., Filippini, F., Sudanese, A., Zinghi, G., and Montanaro, L. Cytokine release in mononuclear cells of patients with Co-Cr hip prosthesis. Biomaterials, 1999, 20(12), 1079-1086.
-
(1999)
Biomaterials
, vol.20
, Issue.12
, pp. 1079-1086
-
-
Granchi, D.1
Ciapetti, G.2
Stea, S.3
Savarino, L.4
Filippini, F.5
Sudanese, A.6
Zinghi, G.7
Montanaro, L.8
-
43
-
-
0031938258
-
Wear and osteolysis in total joint replacements
-
Kadoya, Y., Kobayashi, A., and Ohashi, H. Wear and osteolysis in total joint replacements. Acta Orthop. Scand., 1998, 278, Suppl., 1-16.
-
(1998)
Acta Orthop. Scand
, vol.278
, Issue.SUPPL.
, pp. 1-16
-
-
Kadoya, Y.1
Kobayashi, A.2
Ohashi, H.3
-
44
-
-
0028034860
-
Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses
-
Karrholm, J., Borssen, B., Lowenhielm, G., and Snorrason, F., Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J. Bone Jt Surg., 1994, 76B, 912-917.
-
(1994)
J. Bone Jt Surg
, vol.76 B
, pp. 912-917
-
-
Karrholm, J.1
Borssen, B.2
Lowenhielm, G.3
Snorrason, F.4
-
45
-
-
0029363397
-
Canine cemented total hip replacements: State of the art
-
Olmstead, M. L. Canine cemented total hip replacements: state of the art. J. Small Anim. Practice, 1995, 36(9), 395-399.
-
(1995)
J. Small Anim. Practice
, vol.36
, Issue.9
, pp. 395-399
-
-
Olmstead, M.L.1
-
46
-
-
16544373193
-
An animal model for interface tissue formation in cemented hip replacements
-
El-Warrak, A. O., Olmstead, M., Apelt, D., Deiss, F., Noetzli, H., Zlinsky, K., Hilbe, M., Bertschar-Wolfsberger, R., Johnson, A. L., Auer, J., and Von Rechenberg, B. An animal model for interface tissue formation in cemented hip replacements. Vet. Surg., 2004, 33(5), 495-504.
-
(2004)
Vet. Surg
, vol.33
, Issue.5
, pp. 495-504
-
-
El-Warrak, A.O.1
Olmstead, M.2
Apelt, D.3
Deiss, F.4
Noetzli, H.5
Zlinsky, K.6
Hilbe, M.7
Bertschar-Wolfsberger, R.8
Johnson, A.L.9
Auer, J.10
Von Rechenberg, B.11
-
47
-
-
0033996523
-
Correlation between impact strength and fracture toughness of PMMA-based bone cements
-
Lewis, G. and Mdlasi, S. Correlation between impact strength and fracture toughness of PMMA-based bone cements. Biomaterials, 2000, 21, 775-781.
-
(2000)
Biomaterials
, vol.21
, pp. 775-781
-
-
Lewis, G.1
Mdlasi, S.2
-
48
-
-
0034040792
-
Effects of fatigue loading and PMMA precoating on the adhesion and subcritical debonding of prosthetic-PMMA interfaces
-
Ohashi, K, L. and Dauskardt, R. H. Effects of fatigue loading and PMMA precoating on the adhesion and subcritical debonding of prosthetic-PMMA interfaces. J. Biomed. Mater Res., 2000, 51, 172-183.
-
(2000)
J. Biomed. Mater Res
, vol.51
, pp. 172-183
-
-
Ohashi, K.L.1
Dauskardt, R.H.2
-
49
-
-
0028825376
-
Aseptic loosening in uncemented total hip arthroplasty in a canine model
-
Dowd, J. E., Schwendeman, L. J., Macaulay, W., Doyle, J. S., Shanbhag, A. S., and Wilson, S. Aseptic loosening in uncemented total hip arthroplasty in a canine model. Clin. Orthop. Related Res., 1995, 319, 106-121.
-
(1995)
Clin. Orthop. Related Res
, vol.319
, pp. 106-121
-
-
Dowd, J.E.1
Schwendeman, L.J.2
Macaulay, W.3
Doyle, J.S.4
Shanbhag, A.S.5
Wilson, S.6
-
50
-
-
0030506597
-
Technique and results for total hip replacement in sheep: An experimental model
-
Bruns, D., Olmstead, M. L., and Litsky, A. Technique and results for total hip replacement in sheep: an experimental model. Vet. Comp. Orthop. Traumatology, 1996, 9, 158-164.
-
(1996)
Vet. Comp. Orthop. Traumatology
, vol.9
, pp. 158-164
-
-
Bruns, D.1
Olmstead, M.L.2
Litsky, A.3
-
52
-
-
0032206251
-
Variable length scale analysis of surface topography: Characterization of titanium surfaces for biomedical applications
-
Chauvy, P. F., Madore, C., and Landolt, D. Variable length scale analysis of surface topography: characterization of titanium surfaces for biomedical applications. Surf Coatings Technol., 1998, 110, 48-56.
-
(1998)
Surf Coatings Technol
, vol.110
, pp. 48-56
-
-
Chauvy, P.F.1
Madore, C.2
Landolt, D.3
-
53
-
-
0002824843
-
Surface-enhanced Raman spectroelectrochemical studies of corrosion films on implant Co-Cr-Mo alloy in biosimulating solutions
-
Lip Y.-S., Wang, K., He, P., Huang, B. X., and Kovacs, P. Surface-enhanced Raman spectroelectrochemical studies of corrosion films on implant Co-Cr-Mo alloy in biosimulating solutions. J. Raman Spectrosc., 1999, 30, 97-103.
-
(1999)
J. Raman Spectrosc
, vol.30
, pp. 97-103
-
-
Lip, Y.-S.1
Wang, K.2
He, P.3
Huang, B.X.4
Kovacs, P.5
-
54
-
-
1342264209
-
Passive and transpassive behaviour of CoCrMo in simulated biological solutions
-
Hodgson, A. W. E., Kurz, S., Virtanen, S., Fervel, V., Olsson, C. O. A., and Mischler, S. Passive and transpassive behaviour of CoCrMo in simulated biological solutions. Electrochimica Acta, 2004, 49, 2167-2178.
-
(2004)
Electrochimica Acta
, vol.49
, pp. 2167-2178
-
-
Hodgson, A.W.E.1
Kurz, S.2
Virtanen, S.3
Fervel, V.4
Olsson, C.O.A.5
Mischler, S.6
-
56
-
-
0033372378
-
Increased blood cobalt and chromium after hip replacement
-
Schaffer, A. W., Pilger, A., Engelhardt, C., Zweymueller, K., and Ruediger, H. W. Increased blood cobalt and chromium after hip replacement. J. Toxic. Clin. Toxic., 1999, 37, 839-844.
-
(1999)
J. Toxic. Clin. Toxic
, vol.37
, pp. 839-844
-
-
Schaffer, A.W.1
Pilger, A.2
Engelhardt, C.3
Zweymueller, K.4
Ruediger, H.W.5
-
57
-
-
0020965469
-
Serum concentrations of chromium, cobalt and nickel after total hip replacement: A six month study
-
Black, J., Maitin, E. C., Gelman, H., and Morris, D. M. Serum concentrations of chromium, cobalt and nickel after total hip replacement: a six month study. Biomaterials, 1983, 4, 160-164.
-
(1983)
Biomaterials
, vol.4
, pp. 160-164
-
-
Black, J.1
Maitin, E.C.2
Gelman, H.3
Morris, D.M.4
-
58
-
-
0029814931
-
Distribution of cobalt-chromium wear and corrosion products and biologic reactions
-
Merritt, K. and Brown, S. A. Distribution of cobalt-chromium wear and corrosion products and biologic reactions. Clin. Orthop. Related Res., 1996, 329, Suppl., S233-S243.
-
(1996)
Clin. Orthop. Related Res
, vol.329
, Issue.SUPPL.
-
-
Merritt, K.1
Brown, S.A.2
|