Diagnostic Agreement at the Total Hip Using Different DXA Systems and the NHANES III Database

Author keywords

DXA; osteoporosis; reference database; T score

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; COMPARATIVE STUDY; CONTROLLED STUDY; DATA BASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; HIP; HUMAN; LUMBAR SPINE; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SCORING SYSTEM;

EID: 34247606624     PISSN: 10946950     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jocd.2007.02.003     Document Type: Article
Times cited : (15)

References (22)
  • 1
    • 0026675710 scopus 로고
    • Assessment of spinal and femoral bone density by dual x-ray absorptiometry: comparison of Lunar and Hologic instruments
    • Pocock N.A., Sambrook P.N., Nguyen T., Kelly P., Freund J., and Eisman J.A. Assessment of spinal and femoral bone density by dual x-ray absorptiometry: comparison of Lunar and Hologic instruments. J Bone Miner Res 7 9 (1992) 1081-1084
    • (1992) J Bone Miner Res , vol.7 , Issue.9 , pp. 1081-1084
    • Pocock, N.A.1    Sambrook, P.N.2    Nguyen, T.3    Kelly, P.4    Freund, J.5    Eisman, J.A.6
  • 2
    • 0027096413 scopus 로고
    • Comparison of the effect of different reference data on Lunar DPX and Hologic QDR-1000 dual-energy x-ray absorptiometers
    • Laskey M.A., Crisp A.J., Cole T.J., and Compston J.E. Comparison of the effect of different reference data on Lunar DPX and Hologic QDR-1000 dual-energy x-ray absorptiometers. Br J Radiol 65 (1992) 1124-1129
    • (1992) Br J Radiol , vol.65 , pp. 1124-1129
    • Laskey, M.A.1    Crisp, A.J.2    Cole, T.J.3    Compston, J.E.4
  • 3
    • 0027967093 scopus 로고
    • Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration results
    • Genant H.K., Grampp S., Gluer C.C., et al. Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration results. J Bone Miner Metab 9 10 (1994) 1503-1515
    • (1994) J Bone Miner Metab , vol.9 , Issue.10 , pp. 1503-1515
    • Genant, H.K.1    Grampp, S.2    Gluer, C.C.3
  • 4
    • 0030445883 scopus 로고    scopus 로고
    • Discrepancies in normative data between Lunar and Hologic DXA systems
    • Faulkner K.G., Roberts L.A., and McClung M.R. Discrepancies in normative data between Lunar and Hologic DXA systems. Osteoporos Int 6 (1996) 432-436
    • (1996) Osteoporos Int , vol.6 , pp. 432-436
    • Faulkner, K.G.1    Roberts, L.A.2    McClung, M.R.3
  • 5
    • 3042698429 scopus 로고    scopus 로고
    • Impact of using the ultradistal radius region of interest on diagnostic classification
    • Kiebzak G.M., Lewiecki E.M., and Petak S.M. Impact of using the ultradistal radius region of interest on diagnostic classification. J Clin Densitom 7 2 (2004) 143-152
    • (2004) J Clin Densitom , vol.7 , Issue.2 , pp. 143-152
    • Kiebzak, G.M.1    Lewiecki, E.M.2    Petak, S.M.3
  • 6
    • 16844369059 scopus 로고    scopus 로고
    • The tale of the T-score: review and perspective
    • Faulkner K.G. The tale of the T-score: review and perspective. Osteoporos Int 16 (2005) 347-352
    • (2005) Osteoporos Int , vol.16 , pp. 347-352
    • Faulkner, K.G.1
  • 7
    • 0031201603 scopus 로고    scopus 로고
    • Standardization of femur BMD
    • Hanson J. Standardization of femur BMD. J Bone Miner Res 12 (1997) 1316-1317
    • (1997) J Bone Miner Res , vol.12 , pp. 1316-1317
    • Hanson, J.1
  • 8
    • 0028968710 scopus 로고
    • Prevalence of low femoral bone density in older US women from NHANES III
    • Looker A.C., Johnston C.C., Wahner H.W., et al. Prevalence of low femoral bone density in older US women from NHANES III. J Bone Miner Res 10 5 (1995) 796-802
    • (1995) J Bone Miner Res , vol.10 , Issue.5 , pp. 796-802
    • Looker, A.C.1    Johnston, C.C.2    Wahner, H.W.3
  • 9
    • 0029318474 scopus 로고
    • Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration
    • [letter to the editor]
    • Genant H. Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration. [letter to the editor]. J Bone Miner Res 10 (1995) 997-998
    • (1995) J Bone Miner Res , vol.10 , pp. 997-998
    • Genant, H.1
  • 10
    • 0029134752 scopus 로고
    • Standardization of spine BMD measurements
    • [letter to the editor]
    • Steiger P. Standardization of spine BMD measurements. [letter to the editor]. J Bone Miner Res 9 (1995) 1602-1603
    • (1995) J Bone Miner Res , vol.9 , pp. 1602-1603
    • Steiger, P.1
  • 11
    • 0034963997 scopus 로고    scopus 로고
    • Standardization of bone mineral density at femoral neck, trochanter and Ward's triangle
    • Lu Y., Fuerst T., Hui S., and Genant H.K. Standardization of bone mineral density at femoral neck, trochanter and Ward's triangle. Osteoporos Int 12 (2001) 438-444
    • (2001) Osteoporos Int , vol.12 , pp. 438-444
    • Lu, Y.1    Fuerst, T.2    Hui, S.3    Genant, H.K.4
  • 12
    • 12544256531 scopus 로고    scopus 로고
    • Recalculation of the NHANES database SD improves T-score agreement and reduces osteoporosis prevalence
    • Binkley N., Kiebzak G.M., Lewiecki E.M., et al. Recalculation of the NHANES database SD improves T-score agreement and reduces osteoporosis prevalence. J Bone Miner Res 20 2 (2005) 195-201
    • (2005) J Bone Miner Res , vol.20 , Issue.2 , pp. 195-201
    • Binkley, N.1    Kiebzak, G.M.2    Lewiecki, E.M.3
  • 13
    • 0028306362 scopus 로고
    • Assessment of fracture risk and its application to screening for postmenopausal osteoporosis
    • Assessment of fracture risk and its application to screening for postmenopausal osteoporosis. World Health Organ Tech Rep Ser 843 (1994) 1-129
    • (1994) World Health Organ Tech Rep Ser , vol.843 , pp. 1-129
  • 14
    • 4444223341 scopus 로고    scopus 로고
    • Precision comparison of two DXA densitometers-Prodigy and Delphi
    • [abstract]
    • Lewiecki E.M., and Miller P.D. Precision comparison of two DXA densitometers-Prodigy and Delphi. [abstract]. J Bone Miner Res 18 Suppl 2 (2003) S205
    • (2003) J Bone Miner Res , vol.18 , Issue.SUPPL. 2
    • Lewiecki, E.M.1    Miller, P.D.2
  • 16
    • 1242284385 scopus 로고    scopus 로고
    • Nomenclature and decimal places in bone densitometry
    • The Writing Group for the ISCD Position Development Conference
    • The Writing Group for the ISCD Position Development Conference. Nomenclature and decimal places in bone densitometry. J Clin Densitom 7 1 (2004) 45-49
    • (2004) J Clin Densitom , vol.7 , Issue.1 , pp. 45-49
  • 17
    • 34247604750 scopus 로고    scopus 로고
    • Variability around the T-score cutpoint of 2.5 impacts diagnostic classification
    • [abstract]
    • Kiebzak G.M., Hamdy R.C., Seier E., and Watts N.B. Variability around the T-score cutpoint of 2.5 impacts diagnostic classification. [abstract]. J Clin Densitom 8 2 (2005) 238
    • (2005) J Clin Densitom , vol.8 , Issue.2 , pp. 238
    • Kiebzak, G.M.1    Hamdy, R.C.2    Seier, E.3    Watts, N.B.4
  • 18
    • 34247630866 scopus 로고    scopus 로고
    • Determination of T-score confidence limits for diagnosing osteoporosis
    • [abstract]
    • Faulkner K.G., Weyland L.S., Wacker W.K., and Barden H.S. Determination of T-score confidence limits for diagnosing osteoporosis. [abstract]. J Clin Densitom 9 2 (2006) 237
    • (2006) J Clin Densitom , vol.9 , Issue.2 , pp. 237
    • Faulkner, K.G.1    Weyland, L.S.2    Wacker, W.K.3    Barden, H.S.4
  • 19
    • 34247574442 scopus 로고    scopus 로고
    • Effect of precision error on T-scores and the diagnostic classification of bone status
    • (In press)
    • Kiebzak G.M., Faulkner K.G., Wacker W., Hamdy R., Seier E., and Watts N. Effect of precision error on T-scores and the diagnostic classification of bone status. J Clin Densitom (2007) (In press)
    • (2007) J Clin Densitom
    • Kiebzak, G.M.1    Faulkner, K.G.2    Wacker, W.3    Hamdy, R.4    Seier, E.5    Watts, N.6
  • 20
    • 0037364029 scopus 로고    scopus 로고
    • Discordance in lumbar spine T-scores and nonstandardization of standard deviations
    • McMahon K., Kalnins S., Freund J., and Pocock N. Discordance in lumbar spine T-scores and nonstandardization of standard deviations. J Clin Densitom 6 1 (2003) 1-6
    • (2003) J Clin Densitom , vol.6 , Issue.1 , pp. 1-6
    • McMahon, K.1    Kalnins, S.2    Freund, J.3    Pocock, N.4
  • 21
    • 33646834901 scopus 로고    scopus 로고
    • Skeletal sites for osteoporosis diagnosis: the 2005 ISCD official positions
    • Hans D., Downs R.W., Duboeuf F., et al. Skeletal sites for osteoporosis diagnosis: the 2005 ISCD official positions. J Clin Densitom 9 1 (2006) 15-21
    • (2006) J Clin Densitom , vol.9 , Issue.1 , pp. 15-21
    • Hans, D.1    Downs, R.W.2    Duboeuf, F.3
  • 22
    • 1242329188 scopus 로고    scopus 로고
    • Technical standardization for dual-energy x-ray absorptiometry
    • The Writing Group for the ISCD Position Development Conference
    • The Writing Group for the ISCD Position Development Conference. Technical standardization for dual-energy x-ray absorptiometry. J Clin Densitom 7 1 (2004) 27-36
    • (2004) J Clin Densitom , vol.7 , Issue.1 , pp. 27-36


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.