메뉴 건너뛰기




Volumn 48, Issue 7, 2007, Pages 2119-2128

Control of four leg inverter for hybrid power system applications with unbalanced load

Author keywords

Converters; Current control; Hybrid power system; Power quality; Symmetrical components; Voltage unbalance

Indexed keywords

COMPUTER SIMULATION; ELECTRIC CURRENT CONTROL; ELECTRIC CURRENTS; ELECTRIC POTENTIAL; ELECTRIC TRANSFORMERS; POWER QUALITY; TWO TERM CONTROL SYSTEMS;

EID: 34247597913     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2006.12.019     Document Type: Article
Times cited : (72)

References (13)
  • 1
    • 34247559092 scopus 로고    scopus 로고
    • Ian Baring-Gould E, Flowers L, Lundsager P. Worldwide Status of Wind-Diesel Applications. Pre-Workshop Wind-Diesel 101, Anchorage, Alaska, 2004.
  • 2
    • 0036577307 scopus 로고    scopus 로고
    • Three-dimensional space vector modulation for four-leg voltage-source converters
    • Zhang R., Prasad V.H., Boroyevich D., and Lee F.C. Three-dimensional space vector modulation for four-leg voltage-source converters. IEEE Trans Power Electron 17 3 (2002)
    • (2002) IEEE Trans Power Electron , vol.17 , Issue.3
    • Zhang, R.1    Prasad, V.H.2    Boroyevich, D.3    Lee, F.C.4
  • 3
    • 0034580166 scopus 로고    scopus 로고
    • El-Barbari S, Hofmann W. Digital control of four-leg inverter for standalone photovoltaic systems with unbalanced load. Industrial Electronics Society, 2000. IECON 2000. In: 26th Annual conference of the IEEE vol. 1, 22-28 October 2000. p. 729-34.
  • 4
    • 12344250880 scopus 로고    scopus 로고
    • New control approach for four-wire active power filter based on the use of synchronous reference frame
    • Benhabib M.C., and Saadate S. New control approach for four-wire active power filter based on the use of synchronous reference frame. Electric Power Syst Res 73 3 (2005) 353-362
    • (2005) Electric Power Syst Res , vol.73 , Issue.3 , pp. 353-362
    • Benhabib, M.C.1    Saadate, S.2
  • 5
    • 0035149031 scopus 로고    scopus 로고
    • Botterón F, Pinheiro H, Gründling HA, Pinheiro JR, Hey HL. Digital voltage and current controllers for three-phase PWM inverter for UPS applications. In: Industry applications conference, vol. 4, 2001. p. 2667-74.
  • 6
    • 0033309046 scopus 로고    scopus 로고
    • Ryan MJ, De Doncker RW, Lorenz RD. Decoupled control of a 4-leg inverter via a new 4 × 4 transformation matrix. In: Power electronics specialists conference, 1999. PESC 99, 30th Annual IEEE, vol. 1, August 1999, p. 187-92.
  • 7
    • 34247595921 scopus 로고    scopus 로고
    • Vechiu I, Camblong H, Tapia G, Dakyo B, Curea O. Modelling and control of four-wire voltage source inverter under unbalanced voltage condition for hybrid power system applications. In: EPE conference, CD-ROM, Dresden, 2005.
  • 8
    • 2542589126 scopus 로고
    • Averaged modelling of switching power converters: reformulation and theoretical basis
    • Sun J., and Grotstollen H. Averaged modelling of switching power converters: reformulation and theoretical basis. IEEE PESC'92 (1992) 1166-1172
    • (1992) IEEE PESC'92 , pp. 1166-1172
    • Sun, J.1    Grotstollen, H.2
  • 11
    • 84886500518 scopus 로고
    • Method of symmetrical coordinates applied to the solution of polyphase networks
    • Fortescue C.L. Method of symmetrical coordinates applied to the solution of polyphase networks. AIEE Trans 37 Part II (1918) 1027-1140
    • (1918) AIEE Trans , vol.37 , Issue.PART II , pp. 1027-1140
    • Fortescue, C.L.1
  • 13
    • 34247607695 scopus 로고    scopus 로고
    • EN 50160. Voltage characteristics of electricity supplied by public distribution systems. CENELEC, Belgium, 1999.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.