메뉴 건너뛰기




Volumn 123, Issue 2, 2007, Pages 877-881

Ammonia bio-sniffer with flavin-containing monooxygenase

Author keywords

Bio sniffer; Enzyme; Flavin containing monooxygenase 3; l Ascorbic acid; Reducing reagent system

Indexed keywords

AMMONIA; COMPRESSORS; DISSOLVED OXYGEN; ELECTROCHEMICAL ELECTRODES; ENZYME KINETICS; KETONES; POLYVINYL ALCOHOLS;

EID: 34247585531     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2006.10.045     Document Type: Article
Times cited : (10)

References (30)
  • 3
    • 0036846881 scopus 로고    scopus 로고
    • Breath ammonia measurement in helicobacter pylori infection
    • Kearney D.J., Hubbard T., and Putnam D. Breath ammonia measurement in helicobacter pylori infection. Digest. Dis. Sci. 47 (2002) 2523-2530
    • (2002) Digest. Dis. Sci. , vol.47 , pp. 2523-2530
    • Kearney, D.J.1    Hubbard, T.2    Putnam, D.3
  • 4
    • 0035145289 scopus 로고    scopus 로고
    • Measurement of ammonia in blood
    • Barsotti R.J. Measurement of ammonia in blood. J. Pediatr. 138 Suppl. (2001) S11-S20
    • (2001) J. Pediatr. , vol.138 , Issue.SUPPL
    • Barsotti, R.J.1
  • 9
    • 0001429337 scopus 로고
    • Polymer membrane electrode based potentiometric ammonia gas sensor
    • Meyerhoff M.E. Polymer membrane electrode based potentiometric ammonia gas sensor. Anal. Chem. 52 (1980) 1532-1534
    • (1980) Anal. Chem. , vol.52 , pp. 1532-1534
    • Meyerhoff, M.E.1
  • 10
    • 0042060126 scopus 로고
    • Automated determination of ammonia with a potentiometric gas sensor and flowing internal electrolyte
    • Fraticelli Y.M., and Meyerhoff M.E. Automated determination of ammonia with a potentiometric gas sensor and flowing internal electrolyte. Anal. Chem. 53 (1981) 992-997
    • (1981) Anal. Chem. , vol.53 , pp. 992-997
    • Fraticelli, Y.M.1    Meyerhoff, M.E.2
  • 11
    • 0032099044 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    • Buhlmann P., Pretsch E., and Bakker E. Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors. Chem. Rev. 98 (1998) 1593-1687
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1687
    • Buhlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 12
    • 0000147035 scopus 로고
    • Selective ionophore-based optical sensors for ammonia measurement in air
    • West S.J., Ozawa S., Seiler K., Tan S.S.S., and Simon W. Selective ionophore-based optical sensors for ammonia measurement in air. Anal. Chem. 64 (1992) 533-540
    • (1992) Anal. Chem. , vol.64 , pp. 533-540
    • West, S.J.1    Ozawa, S.2    Seiler, K.3    Tan, S.S.S.4    Simon, W.5
  • 13
    • 0028406701 scopus 로고
    • An optochemical ammonia sensor based on immobilized metalloporpyrins
    • Morales-Bahnik A., Czolk R., and Ache H.J. An optochemical ammonia sensor based on immobilized metalloporpyrins. Sensor. Actuat. B: Chem. 19 (1994) 493-494
    • (1994) Sensor. Actuat. B: Chem. , vol.19 , pp. 493-494
    • Morales-Bahnik, A.1    Czolk, R.2    Ache, H.J.3
  • 14
    • 0015184110 scopus 로고
    • Comparison of mitochondrial monoamine oxidases from bovine brain and liver using antibody to purified liver monoamine oxidase
    • Hidaka H., Hartman B., and Udenfriend S. Comparison of mitochondrial monoamine oxidases from bovine brain and liver using antibody to purified liver monoamine oxidase. Arch. Biochem. Biophys. 147 (1971) 805-809
    • (1971) Arch. Biochem. Biophys. , vol.147 , pp. 805-809
    • Hidaka, H.1    Hartman, B.2    Udenfriend, S.3
  • 15
    • 0015832224 scopus 로고
    • Separation of two monoamine oxidases from bovine bran
    • McCauley R., and Racker E. Separation of two monoamine oxidases from bovine bran. Mol. Cell Biol. 1 (1973) 73-81
    • (1973) Mol. Cell Biol. , vol.1 , pp. 73-81
    • McCauley, R.1    Racker, E.2
  • 16
    • 0017720599 scopus 로고
    • Molecular weight estimation of bovine brain mitochondrial monoamine oxidase
    • Aoki S., Manabe T., and Okuyama T. Molecular weight estimation of bovine brain mitochondrial monoamine oxidase. J. Biochem. 82 (1977) 1533-1539
    • (1977) J. Biochem. , vol.82 , pp. 1533-1539
    • Aoki, S.1    Manabe, T.2    Okuyama, T.3
  • 18
    • 0006379649 scopus 로고    scopus 로고
    • Development of a gas-phase biosensor for trimethylamine using a flavin-containing monooxygenase 3
    • Mitsubayashi K., and Hashimoto Y. Development of a gas-phase biosensor for trimethylamine using a flavin-containing monooxygenase 3. Electrochemistry 68 (2000) 901-903
    • (2000) Electrochemistry , vol.68 , pp. 901-903
    • Mitsubayashi, K.1    Hashimoto, Y.2
  • 21
    • 19744362388 scopus 로고    scopus 로고
    • Bioelectronic sniffer with monoamine oxidase for methyl mercaptan vapor
    • Minamide T., Mitsubayashi K., and Saito H. Bioelectronic sniffer with monoamine oxidase for methyl mercaptan vapor. Sensor. Actuat. B: Chem. 108 (2005) 639-645
    • (2005) Sensor. Actuat. B: Chem. , vol.108 , pp. 639-645
    • Minamide, T.1    Mitsubayashi, K.2    Saito, H.3
  • 22
    • 34247560012 scopus 로고    scopus 로고
    • H. Saito, Y. Kaneko, Y. Hashimoto, T. Shirai, H. Kudo, K. Otsuka, K. Mitsubayashi, Ammonia sensor with flavin-containing monooxygenase, Int. J. Environ. Anal. Chem., in press.
  • 23
    • 0037086220 scopus 로고    scopus 로고
    • Bioelectronic nose for methyl mercaptan vapor using xenobiotic metabolizing enzyme: flavin-containing monooxygenase
    • Mitsubayashi K., and Hashimoto Y. Bioelectronic nose for methyl mercaptan vapor using xenobiotic metabolizing enzyme: flavin-containing monooxygenase. Sensor. Actuat. B: Chem. 83 (2002) 35-40
    • (2002) Sensor. Actuat. B: Chem. , vol.83 , pp. 35-40
    • Mitsubayashi, K.1    Hashimoto, Y.2
  • 24
    • 0021529356 scopus 로고
    • A convenient photochemical method to immobilize enzymes
    • Ichimura K. A convenient photochemical method to immobilize enzymes. J. Polym. Sci. 22 (1984) 2817-2828
    • (1984) J. Polym. Sci. , vol.22 , pp. 2817-2828
    • Ichimura, K.1
  • 25
    • 0029175791 scopus 로고
    • Chemically amplified Kojic acid responses of tyrosinase-based biosensor, based on inhibitory effect to substrate recycling driven by tyrosinase and l-ascorbic acid
    • Hasebe Y., Oshima K., Takise O., and Uchiyama S. Chemically amplified Kojic acid responses of tyrosinase-based biosensor, based on inhibitory effect to substrate recycling driven by tyrosinase and l-ascorbic acid. Talanta 42 (1995) 2079-2085
    • (1995) Talanta , vol.42 , pp. 2079-2085
    • Hasebe, Y.1    Oshima, K.2    Takise, O.3    Uchiyama, S.4
  • 26
    • 0034540797 scopus 로고    scopus 로고
    • Diversity of sulfur compound production in lactic acid bacteria
    • Seefeldt K.E., and Weimer B.C. Diversity of sulfur compound production in lactic acid bacteria. J. Dairy Sci. 83 (2000) 2740-2746
    • (2000) J. Dairy Sci. , vol.83 , pp. 2740-2746
    • Seefeldt, K.E.1    Weimer, B.C.2
  • 27
    • 0027954212 scopus 로고
    • Aseorbate and transition-metal mediation of methanethiol oxidation to dimethyl disulfide and dimethyl trisulfide
    • Chin H.-W., and Lindsay R.C. Aseorbate and transition-metal mediation of methanethiol oxidation to dimethyl disulfide and dimethyl trisulfide. J. Food Chem. 49 (1994) 387-392
    • (1994) J. Food Chem. , vol.49 , pp. 387-392
    • Chin, H.-W.1    Lindsay, R.C.2
  • 29
    • 0026896695 scopus 로고
    • MgO-doped Cr2O3: solubility limit and the effect of doping on the resistivity and ethanol sensitivity
    • Chen Z., and Colbow K. MgO-doped Cr2O3: solubility limit and the effect of doping on the resistivity and ethanol sensitivity. Sensor. Actuat. B: Chem. 9 (1992) 49-53
    • (1992) Sensor. Actuat. B: Chem. , vol.9 , pp. 49-53
    • Chen, Z.1    Colbow, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.