메뉴 건너뛰기




Volumn 31, Issue 5, 2007, Pages 377-383

Extracorporeal circulation, optimized: A pilot study

Author keywords

Miniaturized cardiopulmonary bypass

Indexed keywords

BY PASS; BYPASS SYSTEMS; CARDIOPULMONARY BYPASS; CORONARY ARTERIES; END-POINTS; EXTRACORPOREAL CIRCULATION; GROUP III; MINIATURIZED CARDIOPULMONARY BYPASS; PHOSPHORYLCHOLINE; PILOT STUDIES;

EID: 34247556084     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2007.00395.x     Document Type: Conference Paper
Times cited : (7)

References (12)
  • 1
    • 0041597570 scopus 로고
    • Application of a mechanical heart and lung apparatus to cardiac surgery
    • In: Minneapolis, MN: University of Minnesota
    • Gibbon JH, Jr. Application of a mechanical heart and lung apparatus to cardiac surgery. In:Recent Advances in Cardiovascular Physiology and Surgery. Minneapolis, MN:University of Minnesota, 1953:107 13.
    • (1953) Recent Advances in Cardiovascular Physiology and Surgery. , pp. 107-113
    • Gibbon, J.H.1
  • 2
    • 0037392220 scopus 로고    scopus 로고
    • Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: A prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting
    • Puskas JD, Williams WH, Duke PG, et al. Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: a prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting. J Thorac Cardiovasc Surg 2003 125:797 808.
    • (2003) J Thorac Cardiovasc Surg , vol.125 , pp. 797-808
    • Puskas, J.D.1    Williams, W.H.2    Duke, P.G.3
  • 3
    • 0001063558 scopus 로고
    • A mechanism to eliminate the donor blood prime from the pump oxygenators
    • Panico FC, Neptune WB. A mechanism to eliminate the donor blood prime from the pump oxygenators. Surg Forum 1959 10:605 9.
    • (1959) Surg Forum , vol.10 , pp. 605-609
    • Panico, F.C.1    Neptune, W.B.2
  • 4
    • 0001403486 scopus 로고
    • Open heart operations with disposable oxygenators, 5% dextrose and normothermia
    • Cooley DA, Beaull AC, Grondin P. Open heart operations with disposable oxygenators, 5% dextrose and normothermia. Surgery 1962 52:713 9.
    • (1962) Surgery , vol.52 , pp. 713-719
    • Cooley, D.A.1    Beaull, A.C.2    Grondin, P.3
  • 5
    • 0030074772 scopus 로고    scopus 로고
    • Con: A hematocrit of 20% is not adequate for separation from cardiopulmonary bypass
    • Mossad E, Estafanous F. Con: a hematocrit of 20% is not adequate for separation from cardiopulmonary bypass. J Cardiothorac Vasc Anesth 1996 10:294 5.
    • (1996) J Cardiothorac Vasc Anesth , vol.10 , pp. 294-295
    • Mossad, E.1    Estafanous, F.2
  • 6
    • 0343811706 scopus 로고    scopus 로고
    • Impact of minimum hematocrit during cardiopulmonary bypass on mortality in patients undergoing coronary artery surgery
    • Fang WC, Helm RE, Krieger KH, et al. Impact of minimum hematocrit during cardiopulmonary bypass on mortality in patients undergoing coronary artery surgery. Circulation 1997 96 (Suppl. 2 194 9.
    • (1997) Circulation , vol.96 , Issue.2 , pp. 194-199
    • Fang, W.C.1    Helm, R.E.2    Krieger, K.H.3
  • 7
    • 0035098668 scopus 로고    scopus 로고
    • Lowest hematocrit on bypass and adverse outcome associated with coronary artery bypass grafting
    • DeFoe GR, Ross CS, Olmstead EM, et al. Lowest hematocrit on bypass and adverse outcome associated with coronary artery bypass grafting. Ann Thorac Surg 2001 71:769 76.
    • (2001) Ann Thorac Surg , vol.71 , pp. 769-776
    • Defoe, G.R.1    Ross, C.S.2    Olmstead, E.M.3
  • 8
    • 0036770386 scopus 로고    scopus 로고
    • Closed, phosphorylcholine-coated circuit and reduction of systemic heparinization for cardiopulmonary bypass: The intraoperative ECMO concept
    • Ranucci M, Pazzaglia A, Isgro G, et al. Closed, phosphorylcholine-coated circuit and reduction of systemic heparinization for cardiopulmonary bypass: the intraoperative ECMO concept. Int J Artif Organs 2002 25:875 81.
    • (2002) Int J Artif Organs , vol.25 , pp. 875-881
    • Ranucci, M.1    Pazzaglia, A.2    Isgro, G.3
  • 9
    • 0036090385 scopus 로고    scopus 로고
    • Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits
    • Aldea GS, Soltow LO, Chandler WL, et al. Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits. J Thorac Cardiovasc Surg 2002 123:742 55.
    • (2002) J Thorac Cardiovasc Surg , vol.123 , pp. 742-755
    • Aldea, G.S.1    Soltow, L.O.2    Chandler, W.L.3
  • 10
    • 0036147152 scopus 로고    scopus 로고
    • Phosphorylcholine coating offers natural platelet preservation during cardiopulmonary bypass
    • De Somer F, Van Belleghem Y, Caes F, et al. Phosphorylcholine coating offers natural platelet preservation during cardiopulmonary bypass. Perfusion 2002 17:39 44.
    • (2002) Perfusion , vol.17 , pp. 39-44
    • De Somer, F.1    Van Belleghem, Y.2    Caes, F.3
  • 11
    • 0036622186 scopus 로고    scopus 로고
    • Normothermia does not improve postoperative hemostasis nor does it reduce inflammatory activation in patients undergoing primary isolated coronary artery bypass
    • Gaudino M, Zamparelli R, Andreotti F, et al. Normothermia does not improve postoperative hemostasis nor does it reduce inflammatory activation in patients undergoing primary isolated coronary artery bypass. J Thorac Cardiovasc Surg 2002 123:1092 100.
    • (2002) J Thorac Cardiovasc Surg , vol.123 , pp. 1092-1100
    • Gaudino, M.1    Zamparelli, R.2    Andreotti, F.3
  • 12
    • 19344369542 scopus 로고    scopus 로고
    • On-pump beating heart versus off-pump coronary artery bypass surgery - Evidence of pump-induced myocardial injury
    • Rastan AJ, Bittner HB, Gummert JF, et al. On-pump beating heart versus off-pump coronary artery bypass surgery - evidence of pump-induced myocardial injury. Eur J Cardiothorac Surg 2005 27:1057 64.
    • (2005) Eur J Cardiothorac Surg , vol.27 , pp. 1057-1064
    • Rastan, A.J.1    Bittner, H.B.2    Gummert, J.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.