메뉴 건너뛰기




Volumn 22, Issue 5, 2007, Pages 510-517

Biomechanical evaluation of the modified double-plating fixation for the distal radius fracture

Author keywords

Biomechanical analysis; Distal radius fracture; Double plating technique; Finite element; Fracture fixation

Indexed keywords

AXIAL COMPRESSION; BONE; COMPUTERIZED TOMOGRAPHY; FINITE ELEMENT METHOD; FRACTURE FIXATION; NONLINEAR ANALYSIS; TORSIONAL STRESS;

EID: 34247552364     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2006.12.010     Document Type: Article
Times cited : (38)

References (25)
  • 1
    • 0037403146 scopus 로고    scopus 로고
    • Stress analysis of interbody fusion-finite element modeling of intervertebral implant and vertebral body
    • Adam C., Pearcy M., and Mccombe P. Stress analysis of interbody fusion-finite element modeling of intervertebral implant and vertebral body. Clin. Biomech. 18 (2003) 265-272
    • (2003) Clin. Biomech. , vol.18 , pp. 265-272
    • Adam, C.1    Pearcy, M.2    Mccombe, P.3
  • 3
    • 0027179770 scopus 로고
    • Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression
    • Aro H.T., and Chao E.Y.S. Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression. Clin. Orthop. Rel. Res. 293 (1993) 8-17
    • (1993) Clin. Orthop. Rel. Res. , vol.293 , pp. 8-17
    • Aro, H.T.1    Chao, E.Y.S.2
  • 4
    • 0027642617 scopus 로고
    • Development of a degradable composite for orthopaedic use: mechanical evaluation of an hydroxyapatite-polyhydroxybutyrate composite material
    • Boeree N.R., Dove J., Copper J.J., Knowles J., and Hastings G.W. Development of a degradable composite for orthopaedic use: mechanical evaluation of an hydroxyapatite-polyhydroxybutyrate composite material. Biomaterials 14 (1993) 793-796
    • (1993) Biomaterials , vol.14 , pp. 793-796
    • Boeree, N.R.1    Dove, J.2    Copper, J.J.3    Knowles, J.4    Hastings, G.W.5
  • 6
    • 0030767613 scopus 로고    scopus 로고
    • Displaced intra-articular fractures of the distal aspect of the radius: long-term results in young adults after open reduction and internal fixation
    • Catalano L.W., Cole R.J., and Gelbermann R.H. Displaced intra-articular fractures of the distal aspect of the radius: long-term results in young adults after open reduction and internal fixation. J. Bone Joint Surg. 79A (1997) 1290-1302
    • (1997) J. Bone Joint Surg. , vol.79 A , pp. 1290-1302
    • Catalano, L.W.1    Cole, R.J.2    Gelbermann, R.H.3
  • 7
    • 0020364649 scopus 로고
    • Rigidity and stress analysis of external fracture fixation devices-a theoretical approach
    • Chao E.Y.S., Kasman R.A., and An K.N. Rigidity and stress analysis of external fracture fixation devices-a theoretical approach. J. Biomech. 15 (1982) 971-983
    • (1982) J. Biomech. , vol.15 , pp. 971-983
    • Chao, E.Y.S.1    Kasman, R.A.2    An, K.N.3
  • 8
    • 1542345712 scopus 로고    scopus 로고
    • Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis
    • Chen W.P., Tai C.L., Shih C.H., Hsieh P.H., Leou M.C., and Lee M.S. Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis. Clin. Biomech. 19 (2004) 255-262
    • (2004) Clin. Biomech. , vol.19 , pp. 255-262
    • Chen, W.P.1    Tai, C.L.2    Shih, C.H.3    Hsieh, P.H.4    Leou, M.C.5    Lee, M.S.6
  • 9
    • 0032836522 scopus 로고    scopus 로고
    • Supplemental pinning improves the stability of external fixation in distal radius fractures during simulated finger and forearm motion
    • Dunning C.E., Lindsay C.S., Bicknell R.T., Patterson S.D., Johnson J.A., and King G.J. Supplemental pinning improves the stability of external fixation in distal radius fractures during simulated finger and forearm motion. J. Hand Surg. 24 (1999) 992-1000
    • (1999) J. Hand Surg. , vol.24 , pp. 992-1000
    • Dunning, C.E.1    Lindsay, C.S.2    Bicknell, R.T.3    Patterson, S.D.4    Johnson, J.A.5    King, G.J.6
  • 10
    • 0344010061 scopus 로고    scopus 로고
    • A biomechanical evaluation of lateral plating of distal radial shaft fractures
    • Eglseder W.A., Jasper L.E., Davis C.W., and Belkoff S.M. A biomechanical evaluation of lateral plating of distal radial shaft fractures. J. Hand Surg. 28 (2003) 959-963
    • (2003) J. Hand Surg. , vol.28 , pp. 959-963
    • Eglseder, W.A.1    Jasper, L.E.2    Davis, C.W.3    Belkoff, S.M.4
  • 11
    • 0028849835 scopus 로고
    • Design and biomechanics of a plate for the distal radius
    • Gesensway D., Putnam M.D., Mente P.L., and Lewis J.L. Design and biomechanics of a plate for the distal radius. J. Hand Surg. 20 (1995) 1021-1027
    • (1995) J. Hand Surg. , vol.20 , pp. 1021-1027
    • Gesensway, D.1    Putnam, M.D.2    Mente, P.L.3    Lewis, J.L.4
  • 12
    • 0034097721 scopus 로고    scopus 로고
    • Fracture of the distal radius treated by internal fixation and early function
    • Jakob M., Rikli D.A., and Regazzoni P. Fracture of the distal radius treated by internal fixation and early function. J. Bone Joint Surg. [Br] 82 (2000) 340-344
    • (2000) J. Bone Joint Surg. [Br] , vol.82 , pp. 340-344
    • Jakob, M.1    Rikli, D.A.2    Regazzoni, P.3
  • 13
    • 0026335623 scopus 로고
    • Current concepts review fractures of the distal end of the radius
    • Jupiter J.B. Current concepts review fractures of the distal end of the radius. J. Bone Joint Surg. 73A (1991) 461-469
    • (1991) J. Bone Joint Surg. , vol.73 A , pp. 461-469
    • Jupiter, J.B.1
  • 14
    • 29744444378 scopus 로고    scopus 로고
    • Numerical biomechanical investigation of a tooth/implant-supported system with various connector designs and occlusal forces
    • Lin C.L., Wang J.C., and Kuo Y.C. Numerical biomechanical investigation of a tooth/implant-supported system with various connector designs and occlusal forces. J. Biomech. 39 (2006) 453-463
    • (2006) J. Biomech. , vol.39 , pp. 453-463
    • Lin, C.L.1    Wang, J.C.2    Kuo, Y.C.3
  • 15
    • 0021686893 scopus 로고
    • Tendon rupture as a complication after osteosynthesis in the distal radius
    • Lugger L.J., and Pechlaner S. Tendon rupture as a complication after osteosynthesis in the distal radius. Unfallchirurg. 10 5 (1984) 266-270
    • (1984) Unfallchirurg. , vol.10 , Issue.5 , pp. 266-270
    • Lugger, L.J.1    Pechlaner, S.2
  • 16
    • 0037244095 scopus 로고    scopus 로고
    • Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study
    • Osada D., Viegas S.F., Shah M.A., Morris R.P., and Patterson R.M. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J. Hand Surg. 28 (2003) 94-104
    • (2003) J. Hand Surg. , vol.28 , pp. 94-104
    • Osada, D.1    Viegas, S.F.2    Shah, M.A.3    Morris, R.P.4    Patterson, R.M.5
  • 17
  • 18
    • 0033976014 scopus 로고    scopus 로고
    • Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study
    • Peine R., Rikli D.A., Duda G., and Regazzoni P. Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study. J. Hand Surg. 25 (2000) 29-33
    • (2000) J. Hand Surg. , vol.25 , pp. 29-33
    • Peine, R.1    Rikli, D.A.2    Duda, G.3    Regazzoni, P.4
  • 19
    • 0034193846 scopus 로고    scopus 로고
    • Distal radial metaphyseal forces in an extrinsic grip model: implications for postfracture rehabilitation
    • Putnam M.D., Meyer N.J., Nelson E.W., Gesensway D., and Lewis J.L. Distal radial metaphyseal forces in an extrinsic grip model: implications for postfracture rehabilitation. J. Hand Surg. 25 (2000) 469-475
    • (2000) J. Hand Surg. , vol.25 , pp. 469-475
    • Putnam, M.D.1    Meyer, N.J.2    Nelson, E.W.3    Gesensway, D.4    Lewis, J.L.5
  • 21
    • 0024348395 scopus 로고
    • Treatment of unstable Colles' fractures by external fixation
    • Riis J., and Fruensgaard S. Treatment of unstable Colles' fractures by external fixation. J. Hand Surg. 14 (1989) 145-148
    • (1989) J. Hand Surg. , vol.14 , pp. 145-148
    • Riis, J.1    Fruensgaard, S.2
  • 22
    • 0036345794 scopus 로고    scopus 로고
    • The potential of bioresorbable plates and screws in distal radius fracture fixation
    • Rikli D.A., Curtis R., Schilling C., and Goldhahn J. The potential of bioresorbable plates and screws in distal radius fracture fixation. Injury 33 S-B (2002) 77-83
    • (2002) Injury , vol.33 S-B , pp. 77-83
    • Rikli, D.A.1    Curtis, R.2    Schilling, C.3    Goldhahn, J.4
  • 23
    • 0036144837 scopus 로고    scopus 로고
    • An analysis of bone stress and fixation stability using a finite element method of simulated distal radius fractures
    • Rogge R.D., Adams B.D., and Goel V.K. An analysis of bone stress and fixation stability using a finite element method of simulated distal radius fractures. J. Hand Surg. 27A (2002) 86-92
    • (2002) J. Hand Surg. , vol.27 A , pp. 86-92
    • Rogge, R.D.1    Adams, B.D.2    Goel, V.K.3
  • 24
    • 0032701727 scopus 로고    scopus 로고
    • Finite element analysis of a novel design approach to resisting total hip dislocation
    • Scifert C.F., Thomas D., Brown T.D., and Lipman J.D. Finite element analysis of a novel design approach to resisting total hip dislocation. Clin. Biomech. 14 (1999) 697-703
    • (1999) Clin. Biomech. , vol.14 , pp. 697-703
    • Scifert, C.F.1    Thomas, D.2    Brown, T.D.3    Lipman, J.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.