메뉴 건너뛰기




Volumn 6445, Issue , 2007, Pages

Non-invasive blood glucose measurement using multiple laser diodes

Author keywords

Diabetes; Diffuse reflectance; Laser diodes; Near infrared (NIR); Non invasive blood glucose measurement

Indexed keywords

ALGORITHMS; CALIBRATION; MATHEMATICAL MODELS; MEDICAL PROBLEMS; NONINVASIVE MEDICAL PROCEDURES; PATIENT MONITORING;

EID: 34247540850     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.698881     Document Type: Conference Paper
Times cited : (8)

References (13)
  • 3
    • 0025072502 scopus 로고
    • Determination of physiological level of glucose in an aqueos matrix with digitally filtered Fourier transform near-infrared spectra
    • Arnold M. A, Small G. W. Determination of physiological level of glucose in an aqueos matrix with digitally filtered Fourier transform near-infrared spectra. Analytical Chemistry 1990, 62: 1457-1464.
    • (1990) Analytical Chemistry , vol.62 , pp. 1457-1464
    • Arnold, M.A.1    Small, G.W.2
  • 4
    • 0028309433 scopus 로고
    • Non-invasive blood glucose sensors based on near-infrared spectroscopy
    • Heise H. M, Marbach R, Koschinsky T. H, Gries F. A. Non-invasive blood glucose sensors based on near-infrared spectroscopy. Artificial Organs 1994, 18: 439-447.
    • (1994) Artificial Organs , vol.18 , pp. 439-447
    • Heise, H.M.1    Marbach, R.2    Koschinsky, T.H.3    Gries, F.A.4
  • 5
    • 0032823886 scopus 로고    scopus 로고
    • Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy
    • Malin S. F, Ruchti T. L, Blank T. B, Thennadil S. N, Monfre S. L. Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy. Clinical Chemistry 1999, 45: 1651-1658.
    • (1999) Clinical Chemistry , vol.45 , pp. 1651-1658
    • Malin, S.F.1    Ruchti, T.L.2    Blank, T.B.3    Thennadil, S.N.4    Monfre, S.L.5
  • 8
    • 0026779446 scopus 로고    scopus 로고
    • Clinical Chemistry 1992
    • Ashworth L, Gibb I, Alberti K. G. M. M. Hemocue: Evaluation of a portable photometric system for determining glucose in whole blood. Clinical Chemistry 1992, 38/8: 1479-1482.
    • , vol.38 , Issue.8 , pp. 1479-1482
    • Ashworth, L.1    Gibb, I.2    Alberti, K.G.M.3    Hemocue, M.4
  • 10
  • 11
    • 84891711974 scopus 로고
    • Noninvasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip
    • Marbach R, Koschinsky TH, Gries FA, Heise HM. Noninvasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip. Applied Spectroscopy 1993, 7: 875-881.
    • (1993) Applied Spectroscopy , vol.7 , pp. 875-881
    • Marbach, R.1    Koschinsky, T.H.2    Gries, F.A.3    Heise, H.M.4
  • 12
    • 23044440539 scopus 로고    scopus 로고
    • Influence of contact state on NIR diffuse reflectance spectroscopy in vivo
    • Chen W, Liu R, Xu K, Wang RK. Influence of contact state on NIR diffuse reflectance spectroscopy in vivo. Journal of Physics D: Applied Physics 2005, 38: 2691-2695.
    • (2005) Journal of Physics D: Applied Physics , vol.38 , pp. 2691-2695
    • Chen, W.1    Liu, R.2    Xu, K.3    Wang, R.K.4
  • 13
    • 31144451528 scopus 로고    scopus 로고
    • Next step of non-invasive glucose monitor by NIR technique from the well controlled measuring conditions and results
    • Liu R, Deng B, Chen W, Xu K. Next step of non-invasive glucose monitor by NIR technique from the well controlled measuring conditions and results. Optical and Quantum Electronics 2005; 37: 1305-1317.
    • (2005) Optical and Quantum Electronics , vol.37 , pp. 1305-1317
    • Liu, R.1    Deng, B.2    Chen, W.3    Xu, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.