-
1
-
-
27644455162
-
Real-time 3-dimensional echocardiography: a review of the development of the technology and its clinical application
-
Xie M.-X., Wang X.-F., Cheng T.O., Lu Q., Yuan L., and Liu X. Real-time 3-dimensional echocardiography: a review of the development of the technology and its clinical application. Prog. Cardiovasc. Dis. 48 3 (2005) 209-225
-
(2005)
Prog. Cardiovasc. Dis.
, vol.48
, Issue.3
, pp. 209-225
-
-
Xie, M.-X.1
Wang, X.-F.2
Cheng, T.O.3
Lu, Q.4
Yuan, L.5
Liu, X.6
-
2
-
-
0028750857
-
-
P.K. Weber, R.M. Schmitt, B.D. Tylkowski, J. Steck, Optimization of random sparse 2d transducer arrays for 3d electronic beam steering and focusing, in: Proc. IEEE Ultrason. Symp., Cannes, France, vol. 3, 1994, pp. 1503-1506.
-
-
-
-
3
-
-
0031348610
-
-
A. Austeng, S. Holm, P.K. Weber, N. Aakvaag, K. Iranpour, 1d and 2d algorithmically optimized sparse arrays, in: Proc. IEEE Ultrason. Symp., Toronto, Canada, vol. 2, 1997, pp. 1683-1686.
-
-
-
-
4
-
-
0031233539
-
Properties of the beampattern of weight- and layout-optimized sparse arrays
-
Holm S., Elgetun B., and Dahl G. Properties of the beampattern of weight- and layout-optimized sparse arrays. IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 44 5 (1997) 983-991
-
(1997)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.44
, Issue.5
, pp. 983-991
-
-
Holm, S.1
Elgetun, B.2
Dahl, G.3
-
5
-
-
0033100608
-
Thinning and weighting of large planar arrays by simulated annealing
-
Trucco A. Thinning and weighting of large planar arrays by simulated annealing. IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 46 2 (1999) 347-355
-
(1999)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.46
, Issue.2
, pp. 347-355
-
-
Trucco, A.1
-
6
-
-
0038397747
-
Optimal array pattern synthesis using semidefinite programming
-
Wang F., Balakrishnan V., Zhou P.Y., Chen J.J., Yang R., and Frank C. Optimal array pattern synthesis using semidefinite programming. IEEE Trans. Signal Processing 51 5 (2003) 1172-1183
-
(2003)
IEEE Trans. Signal Processing
, vol.51
, Issue.5
, pp. 1172-1183
-
-
Wang, F.1
Balakrishnan, V.2
Zhou, P.Y.3
Chen, J.J.4
Yang, R.5
Frank, C.6
-
7
-
-
0036565949
-
Weighting and thinning wide-band arrays by simulated annealing
-
Trucco A. Weighting and thinning wide-band arrays by simulated annealing. Ultrasonics 40 1-8 (2002) 485-489
-
(2002)
Ultrasonics
, vol.40
, Issue.1-8
, pp. 485-489
-
-
Trucco, A.1
-
8
-
-
0026128882
-
High-speed ultrasound volumetric imaging system - part i: transducer design and beam steering
-
Smith S.W., Pavy Jr. H.G., and von Ramm O.T. High-speed ultrasound volumetric imaging system - part i: transducer design and beam steering. IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 38 2 (1991) 100-108
-
(1991)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.38
, Issue.2
, pp. 100-108
-
-
Smith, S.W.1
Pavy Jr., H.G.2
von Ramm, O.T.3
-
9
-
-
0029777219
-
Optimizing the radiation pattern of sparse periodic linear arrays
-
Lockwood G.R., Li P.-C., O'Donnel M., and Foster F.S. Optimizing the radiation pattern of sparse periodic linear arrays. IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 43 1 (1996) 7-14
-
(1996)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.43
, Issue.1
, pp. 7-14
-
-
Lockwood, G.R.1
Li, P.-C.2
O'Donnel, M.3
Foster, F.S.4
-
10
-
-
0029755721
-
Optimizing the radiation pattern of sparse periodic two-dimensional arrays
-
Lockwood G.R., and Foster F.S. Optimizing the radiation pattern of sparse periodic two-dimensional arrays. IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 43 1 (1996) 15-19
-
(1996)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.43
, Issue.1
, pp. 15-19
-
-
Lockwood, G.R.1
Foster, F.S.2
-
11
-
-
0033880151
-
Sparse 2d array design for real-time rectilinear volumetric imaging
-
Yen J.T., Steinberg J.P., and Smith S.W. Sparse 2d array design for real-time rectilinear volumetric imaging. IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 47 1 (2000) 93-110
-
(2000)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.47
, Issue.1
, pp. 93-110
-
-
Yen, J.T.1
Steinberg, J.P.2
Smith, S.W.3
-
12
-
-
0033624261
-
Application of different spatial sampling patterns for sparse array transducer design
-
Nikolov S.I., and Jensen J.A. Application of different spatial sampling patterns for sparse array transducer design. Ultrasonics 37 10 (2000) 667-671
-
(2000)
Ultrasonics
, vol.37
, Issue.10
, pp. 667-671
-
-
Nikolov, S.I.1
Jensen, J.A.2
-
13
-
-
0036667271
-
Sparse 2d arrays for 3d phased array imaging - design methods
-
Austeng A., and Holm S. Sparse 2d arrays for 3d phased array imaging - design methods. IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 49 8 (2002) 1073-1086
-
(2002)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.49
, Issue.8
, pp. 1073-1086
-
-
Austeng, A.1
Holm, S.2
-
14
-
-
0024872082
-
-
W.A. Smith, The role of piezocomposites in ultrasonic transducers, in: Proc. IEEE Ultrason. Symp., Montreal, Canada, vol. 2, 1989, pp. 755-766.
-
-
-
-
15
-
-
0442279547
-
Volumetric ultrasound imaging using 2d cmut arrays
-
Oralkan M., Ergun A.S., Cheng C.-H., Johnson J.A., Karaman M., Lee T.H., and Khuri-Yakub B.T. Volumetric ultrasound imaging using 2d cmut arrays. IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 50 11 (2003) 1581-1594
-
(2003)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.50
, Issue.11
, pp. 1581-1594
-
-
Oralkan, M.1
Ergun, A.S.2
Cheng, C.-H.3
Johnson, J.A.4
Karaman, M.5
Lee, T.H.6
Khuri-Yakub, B.T.7
-
16
-
-
0035729798
-
-
J.T. Yen, S.W. Smith, Real-time curvilinear and improved rectilinear volumetric imaging, in: Proc. IEEE Ultrason. Symp., Atlanta, GA, vol. 2, 2001, pp. 1117-1122.
-
-
-
-
17
-
-
0742271588
-
Real-time cylindrical curvilinear 3d ultrasound imaging
-
Pua E.C., Yen J.T., and Smith S.W. Real-time cylindrical curvilinear 3d ultrasound imaging. Ultrasonic Imaging 25 (2003) 109-121
-
(2003)
Ultrasonic Imaging
, vol.25
, pp. 109-121
-
-
Pua, E.C.1
Yen, J.T.2
Smith, S.W.3
-
18
-
-
21644447637
-
-
J.E. Kirkebø, A. Austeng, S. Holm, Curved two-dimensional arrays in ultrasound, in: Proc. IEEE Ultrason. Symp., vol. 2, Montreal, Canada, 2004, pp. 1274-1277.
-
-
-
-
20
-
-
0010335752
-
Computed sonography
-
Sanders R., and Hill M. (Eds), Raven Press, New York
-
Maslak S.H. Computed sonography. In: Sanders R., and Hill M. (Eds). Ultrasound Annual 1985 (1985), Raven Press, New York 1-16
-
(1985)
Ultrasound Annual 1985
, pp. 1-16
-
-
Maslak, S.H.1
-
21
-
-
0026189516
-
Beam steering with pulsed two-dimensional transducer arrays
-
Turnbull D.H., and Foster F.S. Beam steering with pulsed two-dimensional transducer arrays. IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 38 4 (1991) 320-333
-
(1991)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.38
, Issue.4
, pp. 320-333
-
-
Turnbull, D.H.1
Foster, F.S.2
-
22
-
-
34247495055
-
-
S. Holm, Minimum sidelobe energy versus minimum peak sidelobe level for sparse array optimization, in: Proc. IEEE Nordic Sign. Proc. Symp., Espoo, Finland, 1996, pp. 227-230. URL http://www.ifi.uio.no/~ftp/publications/preprints/SHolm-5.ps.
-
-
-
-
23
-
-
84937650610
-
A current distribution for broadside arrays which optimizes the relationship between beamwidth and peak sidelobe level
-
Dolph C.L. A current distribution for broadside arrays which optimizes the relationship between beamwidth and peak sidelobe level. Proc. IRE 34 (1946) 335-348
-
(1946)
Proc. IRE
, vol.34
, pp. 335-348
-
-
Dolph, C.L.1
-
24
-
-
0010337391
-
-
C. Boni, M. Richard, S. Barbarossa, Optimal configuration and weighting of non-uniform arrays according to a maximum ISLR criterion, in: Proc. IEEE Int. Conf. Acoust., Speech, Sign. Proc., Adelaide, Australia, vol. V, 1994, pp. 157-160.
-
-
-
-
26
-
-
17144415917
-
-
J.A. Jensen, Simulation of advanced ultrasound systems using field ii, in: Proc. IEEE Int. Symp. Biomed. Imaging, Arlington, VA, vol. 1, 2004, pp. 636-639.
-
-
-
-
27
-
-
0032265807
-
-
J.-M. Bureau, W. Steichen, G. Lebail, A two-dimensional transducer array for real-time 3d medical ultrasound imaging, in: Proc. IEEE Ultrason. Symp., Sendai, Japan, vol. 2, 1998, pp. 1065-1068.
-
-
-
|