-
2
-
-
0019309599
-
Metabolism and toxicity of aluminum in renal failure
-
Alfrey A.C., Hegg A., and Craswell P. Metabolism and toxicity of aluminum in renal failure. Am. J. Clin. Nutr. 33 (1980) 1509-1516
-
(1980)
Am. J. Clin. Nutr.
, vol.33
, pp. 1509-1516
-
-
Alfrey, A.C.1
Hegg, A.2
Craswell, P.3
-
3
-
-
0030995025
-
Aluminum neurotoxicity in preterm infants receiving intravenous-feeding solutions
-
Bishop N.J., Morley R., Day J.P., and Luca A. Aluminum neurotoxicity in preterm infants receiving intravenous-feeding solutions. N. Engl. J. Med. 336 (2006) 1557-1561
-
(2006)
N. Engl. J. Med.
, vol.336
, pp. 1557-1561
-
-
Bishop, N.J.1
Morley, R.2
Day, J.P.3
Luca, A.4
-
4
-
-
0019832810
-
Dialysis encephalopathy, bone disease and anaemia: the aluminum intoxication syndrome during regular haemodialysis
-
Parkinson I.S., Ward M.K., and Kerr D.N. Dialysis encephalopathy, bone disease and anaemia: the aluminum intoxication syndrome during regular haemodialysis. J. Clin. Pathol. 34 (1981) 1285-1294
-
(1981)
J. Clin. Pathol.
, vol.34
, pp. 1285-1294
-
-
Parkinson, I.S.1
Ward, M.K.2
Kerr, D.N.3
-
5
-
-
0022551321
-
Loss of bone resulting from accumulation of aluminum in bone of patients undergoing dialysis
-
Faugere M.C., Arnala I.O., Ritz E., and Malluche H.H. Loss of bone resulting from accumulation of aluminum in bone of patients undergoing dialysis. J. Lab. Clin. Med. 107 (1986) 481-487
-
(1986)
J. Lab. Clin. Med.
, vol.107
, pp. 481-487
-
-
Faugere, M.C.1
Arnala, I.O.2
Ritz, E.3
Malluche, H.H.4
-
6
-
-
0036224783
-
The potential role of aluminium in Alzheimer's disease
-
Campbell A. The potential role of aluminium in Alzheimer's disease. Nephrol. Dial. Transplant. 17 2 (2002) 17-20
-
(2002)
Nephrol. Dial. Transplant.
, vol.17
, Issue.2
, pp. 17-20
-
-
Campbell, A.1
-
8
-
-
19944433257
-
Aluminium in Alzheimer's disease: are we still at a crossroad?
-
Gupta V.B., Anitha S., Hegde M.L., Zecca L., Garruto R.M., Ravid R., Shankar S.K., Stein R., Shanmugavelu P., and Jagannatha Rao K.S. Aluminium in Alzheimer's disease: are we still at a crossroad?. Cell. Mol. Life Sci. 62 (2005) 143-158
-
(2005)
Cell. Mol. Life Sci.
, vol.62
, pp. 143-158
-
-
Gupta, V.B.1
Anitha, S.2
Hegde, M.L.3
Zecca, L.4
Garruto, R.M.5
Ravid, R.6
Shankar, S.K.7
Stein, R.8
Shanmugavelu, P.9
Jagannatha Rao, K.S.10
-
9
-
-
33646180185
-
Aluminum in hippocampal neurons from humans with Alzheimer's disease
-
Walton J.R. Aluminum in hippocampal neurons from humans with Alzheimer's disease. Neurotoxicology 27 (2006) 385-394
-
(2006)
Neurotoxicology
, vol.27
, pp. 385-394
-
-
Walton, J.R.1
-
10
-
-
0034500364
-
Validation of inductively coupled plasma atomic emission spectrometry technique (ICP-AES) for multi-element analysis of trace elements in human serum
-
Rahil-Khazen R., Henriksen H., Bolann B.J., and Ulvik R.J. Validation of inductively coupled plasma atomic emission spectrometry technique (ICP-AES) for multi-element analysis of trace elements in human serum. Scand. J. Clin. Lab. Invest. 60 (2000) 677-686
-
(2000)
Scand. J. Clin. Lab. Invest.
, vol.60
, pp. 677-686
-
-
Rahil-Khazen, R.1
Henriksen, H.2
Bolann, B.J.3
Ulvik, R.J.4
-
12
-
-
0020957010
-
Quality-control sera for routine determination of aluminum by electrothermal atomic absorption spectroscopy
-
Leung F.Y., and Henderson A.R. Quality-control sera for routine determination of aluminum by electrothermal atomic absorption spectroscopy. Clin. Chem. 29 (1983) 1966-1968
-
(1983)
Clin. Chem.
, vol.29
, pp. 1966-1968
-
-
Leung, F.Y.1
Henderson, A.R.2
-
13
-
-
0021796116
-
Measurement of aluminum in serum, blood, urine, and tissues of chronic hemodialyzed patients by use of electrothermal atomic absorption spectrometry
-
D'Haese P.C., Van de Vyver F.L., de Wolff F.A., and De Broe M.E. Measurement of aluminum in serum, blood, urine, and tissues of chronic hemodialyzed patients by use of electrothermal atomic absorption spectrometry. Clin. Chem. 31 (1985) 24-29
-
(1985)
Clin. Chem.
, vol.31
, pp. 24-29
-
-
D'Haese, P.C.1
Van de Vyver, F.L.2
de Wolff, F.A.3
De Broe, M.E.4
-
14
-
-
0031177306
-
Signal oscillation and overcorrection in the determination of aluminum using the transversely heated graphite furnace with Zeeman background correction
-
Tang S., Parsons P.J., and Slavin W. Signal oscillation and overcorrection in the determination of aluminum using the transversely heated graphite furnace with Zeeman background correction. Spectrochim. Acta Part B 52 (1997) 1351-1365
-
(1997)
Spectrochim. Acta Part B
, vol.52
, pp. 1351-1365
-
-
Tang, S.1
Parsons, P.J.2
Slavin, W.3
-
15
-
-
34247469500
-
Aluminium
-
Herber R.F.M., and Stoeppler M. (Eds), Elsevier, New York
-
Savory J., Bertholf R.L., Brown S., and Wills M.R. Aluminium. In: Herber R.F.M., and Stoeppler M. (Eds). Trace Element Analysis in Biological Samples (1994), Elsevier, New York
-
(1994)
Trace Element Analysis in Biological Samples
-
-
Savory, J.1
Bertholf, R.L.2
Brown, S.3
Wills, M.R.4
-
18
-
-
0028881764
-
Transferability of blood lead determinations by furnace atomic absorption spectrophotometry and continuum background correction
-
Qiao H., Parsons P.J., and Slavin W. Transferability of blood lead determinations by furnace atomic absorption spectrophotometry and continuum background correction. Clin. Chem. 41 (1995) 1451-1454
-
(1995)
Clin. Chem.
, vol.41
, pp. 1451-1454
-
-
Qiao, H.1
Parsons, P.J.2
Slavin, W.3
-
20
-
-
0041949704
-
The choice of an analytical Zeeman AAS wavelength for aluminum
-
Manning D.C., and Slavin W. The choice of an analytical Zeeman AAS wavelength for aluminum. At. Spectr. 7 (1986)
-
(1986)
At. Spectr.
, vol.7
-
-
Manning, D.C.1
Slavin, W.2
-
22
-
-
0036310862
-
Harmonized guidelines for single-laboratory validation of methods of analysis (IUPAC technical report)
-
Thompson M., Ellison S.L.R., and Wood R. Harmonized guidelines for single-laboratory validation of methods of analysis (IUPAC technical report). Pure Appl. Chem. 74 (2002) 835-855
-
(2002)
Pure Appl. Chem.
, vol.74
, pp. 835-855
-
-
Thompson, M.1
Ellison, S.L.R.2
Wood, R.3
-
23
-
-
18644374187
-
Comparison of procedures for evaluating laboratory performance in external quality assessment schemes for lead in blood and aluminum in serum demonstrates the need for common quality specifications
-
Taylor A., Angerer J., Claeys F., Kristiansen J., Mazarrasa O., Menditto A., Patriarca M., Pineau A., Schoeters I., Sykes C., Valkonen S., and Weykamp C. Comparison of procedures for evaluating laboratory performance in external quality assessment schemes for lead in blood and aluminum in serum demonstrates the need for common quality specifications. Clin. Chem. 48 (2002) 2000-2007
-
(2002)
Clin. Chem.
, vol.48
, pp. 2000-2007
-
-
Taylor, A.1
Angerer, J.2
Claeys, F.3
Kristiansen, J.4
Mazarrasa, O.5
Menditto, A.6
Patriarca, M.7
Pineau, A.8
Schoeters, I.9
Sykes, C.10
Valkonen, S.11
Weykamp, C.12
-
24
-
-
42149089425
-
The determination of Cr, Cu, and Mn in seawater with transversely heated graphite furnace atomic absorption spectrometry
-
Cabon J.Y., and Lebihan A. The determination of Cr, Cu, and Mn in seawater with transversely heated graphite furnace atomic absorption spectrometry. Spectrochim. Acta Part B 50 (1995) 1703-1716
-
(1995)
Spectrochim. Acta Part B
, vol.50
, pp. 1703-1716
-
-
Cabon, J.Y.1
Lebihan, A.2
-
26
-
-
0032045438
-
Comparison of electrothermal atomic absorption spectrometry, quadrupole inductively coupled plasma mass spectrometry and double-focusing sector field inductively coupled plasma mass spectrometry for the determination of aluminium in human serum
-
Sariego Muñiz C., Marchante-Gayón J.M., Alonso J.I.G., and Sanz-Medel A. Comparison of electrothermal atomic absorption spectrometry, quadrupole inductively coupled plasma mass spectrometry and double-focusing sector field inductively coupled plasma mass spectrometry for the determination of aluminium in human serum. J. Anal. At. Spectrom. 13 (1998) 283-287
-
(1998)
J. Anal. At. Spectrom.
, vol.13
, pp. 283-287
-
-
Sariego Muñiz, C.1
Marchante-Gayón, J.M.2
Alonso, J.I.G.3
Sanz-Medel, A.4
-
27
-
-
0027658473
-
Matrix vapours and physical interference effects in graphite furnace atomic absorption spectrometry - II. Side-heated tubes
-
Frech W., and L'vov B.V. Matrix vapours and physical interference effects in graphite furnace atomic absorption spectrometry - II. Side-heated tubes. Spectrochim. Acta Part B 48 (1993) 1371-1379
-
(1993)
Spectrochim. Acta Part B
, vol.48
, pp. 1371-1379
-
-
Frech, W.1
L'vov, B.V.2
-
28
-
-
0042951279
-
The potentialities of the graphite crucible method in atomic absorption spectroscopy
-
L'vov B.V. The potentialities of the graphite crucible method in atomic absorption spectroscopy. Spectrochim. Acta Part B 24 (1969) 53-56
-
(1969)
Spectrochim. Acta Part B
, vol.24
, pp. 53-56
-
-
L'vov, B.V.1
-
29
-
-
41749122454
-
Electrothermal atomization - the way toward absolute methods of atomic absorption analysis
-
L'vov B.V. Electrothermal atomization - the way toward absolute methods of atomic absorption analysis. Spectrochim. Acta Part B 33 (1977) 153-193
-
(1977)
Spectrochim. Acta Part B
, vol.33
, pp. 153-193
-
-
L'vov, B.V.1
-
31
-
-
34247463934
-
-
Occupational and Environmental Laboratory Medicine (OELM). http://www.occupational-environmental-laboratory.com (Accessed August 8, 2006). 2006.
-
-
-
-
32
-
-
0000068519
-
An external quality assessment scheme for trace element in biological fluids
-
Taylor A., and Briggs R.J. An external quality assessment scheme for trace element in biological fluids. J. Anal. At. Spectrom. 1 (1986) 391-395
-
(1986)
J. Anal. At. Spectrom.
, vol.1
, pp. 391-395
-
-
Taylor, A.1
Briggs, R.J.2
-
33
-
-
1842310635
-
Analytical techniques for the analysis of aluminum
-
Gitelman H.J. (Ed), Dekker, New York
-
Savory J., and Wills M.R. Analytical techniques for the analysis of aluminum. In: Gitelman H.J. (Ed). Aluminum and Health: A Critical Review (1989), Dekker, New York
-
(1989)
Aluminum and Health: A Critical Review
-
-
Savory, J.1
Wills, M.R.2
|