Volumn 243, Issue 2, 2007, Pages 461-466

Transition from screen-film to digital radiography: Evolution of patient radiation doses at projection radiography

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DATA BASE; DIGITAL RADIOGRAPHY; FILM; HUMAN; IMAGE INTENSIFIER; KRUSKAL WALLIS TEST; MEDICAL SOCIETY; ONLINE SYSTEM; PARAMETER; PRIORITY JOURNAL; RADIATION DOSE; RANK SUM TEST; REFERENCE VALUE; RETROSPECTIVE STUDY; STATISTICAL ANALYSIS; TRAINING;

EID: 34247498104     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2432050930     Document Type: Article
Times cited : (55)

References (13)
  • 1
    • 34547755176 scopus 로고    scopus 로고
    • Managing patient dose in digital radiology: A report, of the International Commission on Radiological Protection
    • International Commission on Radiological Protection
    • International Commission on Radiological Protection. Managing patient dose in digital radiology: a report, of the International Commission on Radiological Protection. Ann ICRP 2004;34:1-73.
    • (2004) Ann ICRP , vol.34 , pp. 1-73
  • 2
    • 0036727748 scopus 로고    scopus 로고
    • Digital radiography: Are the manufacturers' settings too high? - optimisation of the Kodak digital radiography system with aid of the computed radiography dose index
    • Peters SE, Brennan PC. Digital radiography: are the manufacturers' settings too high? - optimisation of the Kodak digital radiography system with aid of the computed radiography dose index. Eur Radiol 2002;12:2381-2387.
    • (2002) Eur Radiol , vol.12 , pp. 2381-2387
    • Peters, S.E.1    Brennan, P.C.2
  • 3
    • 0033721534 scopus 로고    scopus 로고
    • Comparison of doses for bedside examinations of the chest with conventional screen-film and computed radiography: Results of a randomized controlled trial
    • Weatherburn GC, Bryan S, Davies JG. Comparison of doses for bedside examinations of the chest with conventional screen-film and computed radiography: results of a randomized controlled trial. Radiology 2000;217: 707-712.
    • (2000) Radiology , vol.217 , pp. 707-712
    • Weatherburn, G.C.1    Bryan, S.2    Davies, J.G.3
  • 4
    • 33846709498 scopus 로고    scopus 로고
    • European guidelines on quality criteria for diagnostic radiographic images
    • European Commission, 16260. Office for the Official Publications of the European Communities. Published, Accessed October 20
    • European Commission. European guidelines on quality criteria for diagnostic radiographic images. Report EUR 16260. Office for the Official Publications of the European Communities. Published 1996. ftp://ftp.cordis .lu/pub/fp5-euratom/docs/eur16260.pdf. Accessed October 20, 2005.
    • (1996) Report EUR
  • 5
    • 0036787309 scopus 로고    scopus 로고
    • Real-time measurement and audit of radiation dose to patients undergoing computed radiography
    • Vano E, Fernandez JM, Ten JI, Guibelalde E, Gonzalez L, Pedrosa CS. Real-time measurement and audit of radiation dose to patients undergoing computed radiography. Radiology 2002;225:283-288.
    • (2002) Radiology , vol.225 , pp. 283-288
    • Vano, E.1    Fernandez, J.M.2    Ten, J.I.3    Guibelalde, E.4    Gonzalez, L.5    Pedrosa, C.S.6
  • 6
    • 0042431708 scopus 로고    scopus 로고
    • Hypothesis testing III: Counts and medians
    • Applegate KE, Tello R, Ying J. Hypothesis testing III: counts and medians. Radiology 2003;228:603-608.
    • (2003) Radiology , vol.228 , pp. 603-608
    • Applegate, K.E.1    Tello, R.2    Ying, J.3
  • 7
    • 34247532545 scopus 로고    scopus 로고
    • Accessed October 20, 2005
    • SPSS Web site. http://www.spss.com. Accessed October 20, 2005.
    • Web site, S.P.S.S.1
  • 8
    • 20244379100 scopus 로고    scopus 로고
    • Reference values for diagnostic radiology: Application and impact
    • Gray JE, Archer BR, Butler PF, et al. Reference values for diagnostic radiology: application and impact. Radiology 2005;235:354-358.
    • (2005) Radiology , vol.235 , pp. 354-358
    • Gray, J.E.1    Archer, B.R.2    Butler, P.F.3
  • 9
    • 0029589751 scopus 로고
    • Image quality and dose in lumbar spine examinations: Results of a 5 year quality control program following the European quality criteria trial
    • Vano E, Oliete S, Gonzalez L, Guibelalde E, Velasco A, Fernandez JM. Image quality and dose in lumbar spine examinations: results of a 5 year quality control program following the European quality criteria trial. Br J Radiol 1995;68:1332-1335.
    • (1995) Br J Radiol , vol.68 , pp. 1332-1335
    • Vano, E.1    Oliete, S.2    Gonzalez, L.3    Guibelalde, E.4    Velasco, A.5    Fernandez, J.M.6
  • 10
    • 85026491604 scopus 로고    scopus 로고
    • Comparison of computed radiography and screen-film combination using a contrast-detail phantom
    • Lu ZF, Nickoloff EL, So JC, Dutta AK. Comparison of computed radiography and screen-film combination using a contrast-detail phantom. J Appl Clin Med Phys 2003;4: 91-98.
    • (2003) J Appl Clin Med Phys , vol.4 , pp. 91-98
    • Lu, Z.F.1    Nickoloff, E.L.2    So, J.C.3    Dutta, A.K.4
  • 12
    • 34247524775 scopus 로고    scopus 로고
    • Performance standard for diagnostic x-ray systems and their major components, 21 CFR §1020.30, §1020.31, §1020.32, and §1020.33 (2005).
    • Performance standard for diagnostic x-ray systems and their major components, 21 CFR §1020.30, §1020.31, §1020.32, and §1020.33 (2005).
  • 13
    • 2442457821 scopus 로고    scopus 로고
    • Radiation dose in digital chest radiography: Comparison among three technologies
    • Saiani F, Ghirardi C, Rodella CA, Feroldi P, Chiesa A. Radiation dose in digital chest radiography: comparison among three technologies. Radiol Med (Torino) 2004;107: 401-407.
    • (2004) Radiol Med (Torino) , vol.107 , pp. 401-407
    • Saiani, F.1    Ghirardi, C.2    Rodella, C.A.3    Feroldi, P.4    Chiesa, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.