메뉴 건너뛰기




Volumn 28, Issue 3, 2007, Pages 364-373

Validation of sperm counting methods using limits of agreement

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTICAL ERROR; ARTICLE; DEVICE; DILUTION; EJACULATION; HEMOCYTOMETER; HUMAN; INTERMETHOD COMPARISON; MAKLER CHAMBER; MALE FERTILITY; MALE INFERTILITY; MASTURBATION; MICROSCOPY; OLIGOSPERMIA; PRIORITY JOURNAL; SAMPLING; SEMEN ANALYSIS; SPERMATOZOON; SPERMATOZOON COUNT; SPERMATOZOON DENSITY; SPERMATOZOON MOTILITY; WORLD HEALTH ORGANIZATION;

EID: 34247491038     PISSN: 01963635     EISSN: None     Source Type: Journal    
DOI: 10.2164/jandrol.106.002188     Document Type: Article
Times cited : (41)

References (19)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland MJ, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, M.J.1    Altman, D.G.2
  • 2
    • 79961152800 scopus 로고    scopus 로고
    • Validation of a new disposable counting chamber
    • Coetzee K, Menkveld R. Validation of a new disposable counting chamber. Arch Androl. 2001;47:153-156.
    • (2001) Arch Androl , vol.47 , pp. 153-156
    • Coetzee, K.1    Menkveld, R.2
  • 4
    • 0024555428 scopus 로고
    • The clinical value of conventional semen analysis
    • Dunphy BC, Neal LM, Cooke ID. The clinical value of conventional semen analysis. Fertil Steril. 1989;51:324-329.
    • (1989) Fertil Steril , vol.51 , pp. 324-329
    • Dunphy, B.C.1    Neal, L.M.2    Cooke, I.D.3
  • 5
    • 0022003661 scopus 로고
    • Relationship between initial blood pressure and its fall with treatment
    • Gill JS, Zezulka AV, Beevers DG, Davies P. Relationship between initial blood pressure and its fall with treatment. Lancet. 1985;1:567-569.
    • (1985) Lancet , vol.1 , pp. 567-569
    • Gill, J.S.1    Zezulka, A.V.2    Beevers, D.G.3    Davies, P.4
  • 6
    • 0025298527 scopus 로고
    • The influence of chamber characteristics on the reliability of sperm concentration and movement measurements obtained by manual and videomicrographic analysis
    • Ginsburg KA, Armant DR. The influence of chamber characteristics on the reliability of sperm concentration and movement measurements obtained by manual and videomicrographic analysis. Fertil Steril. 1990;5:882-887.
    • (1990) Fertil Steril , vol.5 , pp. 882-887
    • Ginsburg, K.A.1    Armant, D.R.2
  • 8
    • 0034093709 scopus 로고    scopus 로고
    • Results of the American association of bioanalysts national proficiency testing programme in andrology
    • Keel BA, Quinn P, Schmidt CF, Serafy NT Jr, Serafy NT Sr, Schalue TK. Results of the American association of bioanalysts national proficiency testing programme in andrology. Hum Reprod. 2000;15:680-686.
    • (2000) Hum Reprod , vol.15 , pp. 680-686
    • Keel, B.A.1    Quinn, P.2    Schmidt, C.F.3    Serafy Jr, N.T.4    Serafy Sr, N.T.5    Schalue, T.K.6
  • 9
    • 34548083713 scopus 로고    scopus 로고
    • Quality evaluation of three different sperm counting chambers (Translated from Chinese)
    • Lu J, Lu N, Huang Y, Li PS, Fisch H. Quality evaluation of three different sperm counting chambers (Translated from Chinese). Zhong Hua Nan Ke Xue. 2004;10:755-757.
    • (2004) Zhong Hua Nan Ke Xue , vol.10 , pp. 755-757
    • Lu, J.1    Lu, N.2    Huang, Y.3    Li, P.S.4    Fisch, H.5
  • 10
    • 0033200111 scopus 로고    scopus 로고
    • Matson P, Irving J, Zuvela E, Hughes R. Delay in the application of the cover glass is a potential source of error with the Makler Counting Chamber. Fertil Steril. 1999;72:559-561.
    • Matson P, Irving J, Zuvela E, Hughes R. Delay in the application of the cover glass is a potential source of error with the Makler Counting Chamber. Fertil Steril. 1999;72:559-561.
  • 12
    • 0025158279 scopus 로고
    • External quality control in the andrology laboratory: An experimental multicentre trial
    • Neuwinger J, Behre HM, Nieschlag E. External quality control in the andrology laboratory: an experimental multicentre trial. Fertil Steril. 1990;54:308-314.
    • (1990) Fertil Steril , vol.54 , pp. 308-314
    • Neuwinger, J.1    Behre, H.M.2    Nieschlag, E.3
  • 13
    • 0029831126 scopus 로고    scopus 로고
    • Accuracy of semen counting chambers as determined by the use of latex beads
    • Seaman EK, Goluboff E, BarChama N, Fisch H. Accuracy of semen counting chambers as determined by the use of latex beads. Fertil Steril. 1996;66:662-665.
    • (1996) Fertil Steril , vol.66 , pp. 662-665
    • Seaman, E.K.1    Goluboff, E.2    BarChama, N.3    Fisch, H.4
  • 14
    • 33645075933 scopus 로고
    • Behaviour of macroscopic rigid spheres in Poiseuille flow
    • Segre G, Silberberg A. Behaviour of macroscopic rigid spheres in Poiseuille flow. J Fluid Mech. 1961;14:115-135.
    • (1961) J Fluid Mech , vol.14 , pp. 115-135
    • Segre, G.1    Silberberg, A.2
  • 15
    • 0028508875 scopus 로고
    • A comparison of Makler counting chamber and improved Neubauer hemocytometer in sperm concentration measurement
    • Sukcharoen N, Ngeamjirawat J, Chanprasit Y, Aribarg A. A comparison of Makler counting chamber and improved Neubauer hemocytometer in sperm concentration measurement. J Medical Ass Thai. 1994;77:471-476.
    • (1994) J Medical Ass Thai , vol.77 , pp. 471-476
    • Sukcharoen, N.1    Ngeamjirawat, J.2    Chanprasit, Y.3    Aribarg, A.4
  • 16
    • 0035186643 scopus 로고    scopus 로고
    • One-step disposable chambers for sperm concentration and motility assessment: How do they compare with the World Health Organisation's recommended methods?
    • Tomlinson M, Turner J, Powell G, Sakkas D. One-step disposable chambers for sperm concentration and motility assessment: how do they compare with the World Health Organisation's recommended methods? Hum Reprod. 2001;16:101-104.
    • (2001) Hum Reprod , vol.16 , pp. 101-104
    • Tomlinson, M.1    Turner, J.2    Powell, G.3    Sakkas, D.4
  • 17
    • 0032853075 scopus 로고    scopus 로고
    • The diagnostic and prognostic value of traditional semen parameters
    • Tomlinson MJ, Kessopoulou E, Barratt CLR. The diagnostic and prognostic value of traditional semen parameters. J Androl. 1999;20:588-593.
    • (1999) J Androl , vol.20 , pp. 588-593
    • Tomlinson, M.J.1    Kessopoulou, E.2    Barratt, C.L.R.3
  • 18
    • 0029822130 scopus 로고    scopus 로고
    • Prognostic indicators for intrauterine insemination (IUI): Statistical model for IUI success
    • Tomlinson MJ, Amissah-Arthur JB, Thompson KA, Kasraie JL, Bentick B. Prognostic indicators for intrauterine insemination (IUI): statistical model for IUI success. Hum Reprod. 1996;11:1892-1896.
    • (1996) Hum Reprod , vol.11 , pp. 1892-1896
    • Tomlinson, M.J.1    Amissah-Arthur, J.B.2    Thompson, K.A.3    Kasraie, J.L.4    Bentick, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.