-
2
-
-
13444303976
-
A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws
-
Kaeding C., Farr J., Kavanaugh T., and Pedroza A. A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws. Arthroscopy 21 (2005) 147-151
-
(2005)
Arthroscopy
, vol.21
, pp. 147-151
-
-
Kaeding, C.1
Farr, J.2
Kavanaugh, T.3
Pedroza, A.4
-
3
-
-
33745808821
-
Arthroscopic double-bundle anterior cruciate ligament reconstruction using autogenous quadriceps tendon
-
Available online at www.arthroscopyjournal.org
-
Kim S.J., Jung K.A., and Song D.H. Arthroscopic double-bundle anterior cruciate ligament reconstruction using autogenous quadriceps tendon. Arthroscopy 22 (2006) 797.e1-797.e5. http://www.arthroscopyjournal.org Available online at www.arthroscopyjournal.org
-
(2006)
Arthroscopy
, vol.22
-
-
Kim, S.J.1
Jung, K.A.2
Song, D.H.3
-
4
-
-
0032606108
-
Comparison of polylactide screw and expansion bolt in bioabsorbable fixation with patellar tendon bone graft for anterior cruciate ligament rupture of the knee. A preliminary study
-
Tuompo P., Partio E.K., Jukkala-Partio K., Pohjonen T., Helevirta P., and Rokkanen P. Comparison of polylactide screw and expansion bolt in bioabsorbable fixation with patellar tendon bone graft for anterior cruciate ligament rupture of the knee. A preliminary study. Knee Surg Sports Traumatol Arthrosc 7 (1999) 296-302
-
(1999)
Knee Surg Sports Traumatol Arthrosc
, vol.7
, pp. 296-302
-
-
Tuompo, P.1
Partio, E.K.2
Jukkala-Partio, K.3
Pohjonen, T.4
Helevirta, P.5
Rokkanen, P.6
-
5
-
-
0033049022
-
Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
-
McGuire D.A., Barber F.A., Elrod B.F., and Paulos L.E. Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 15 (1999) 463-473
-
(1999)
Arthroscopy
, vol.15
, pp. 463-473
-
-
McGuire, D.A.1
Barber, F.A.2
Elrod, B.F.3
Paulos, L.E.4
-
6
-
-
0015588586
-
Resorption rate, route, route of elimination, and ultrastructure of the implant site of polylactic acid in the abdominal wall of the rat
-
Brady J.M., Cutright D.E., Miller R.A., and Barristone G.C. Resorption rate, route, route of elimination, and ultrastructure of the implant site of polylactic acid in the abdominal wall of the rat. J Biomed Mater Res 7 (1973) 155-166
-
(1973)
J Biomed Mater Res
, vol.7
, pp. 155-166
-
-
Brady, J.M.1
Cutright, D.E.2
Miller, R.A.3
Barristone, G.C.4
-
7
-
-
0033023293
-
Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction
-
Warden W.H., Friedman R., Teresi L.M., and Jackson D.W. Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction. Arthroscopy 15 (1999) 474-480
-
(1999)
Arthroscopy
, vol.15
, pp. 474-480
-
-
Warden, W.H.1
Friedman, R.2
Teresi, L.M.3
Jackson, D.W.4
-
9
-
-
0034786399
-
Reconstruction of the anterior cruciate ligament using poly-L-lactide interference screws or titanium screws: A comparative study
-
Kotani A., and Ishii Y. Reconstruction of the anterior cruciate ligament using poly-L-lactide interference screws or titanium screws: A comparative study. Knee 8 (2001) 311-315
-
(2001)
Knee
, vol.8
, pp. 311-315
-
-
Kotani, A.1
Ishii, Y.2
-
10
-
-
0014974494
-
Tissue reaction to the biodegradable polylactic acid suture
-
Cutright D.E., and Hunsuck E.E. Tissue reaction to the biodegradable polylactic acid suture. Oral Surg Oral Med Oral Pathol 31 (1971) 134-139
-
(1971)
Oral Surg Oral Med Oral Pathol
, vol.31
, pp. 134-139
-
-
Cutright, D.E.1
Hunsuck, E.E.2
-
11
-
-
0023205611
-
Resorbable poly (L-lactide) plates and screws for the fixation of zygomatic fractures
-
Bos R.R.M., Boering G., Rozema F.R., and Leenslag J.W. Resorbable poly (L-lactide) plates and screws for the fixation of zygomatic fractures. J Oral Maxillofac Surg 45 (1987) 751-753
-
(1987)
J Oral Maxillofac Surg
, vol.45
, pp. 751-753
-
-
Bos, R.R.M.1
Boering, G.2
Rozema, F.R.3
Leenslag, J.W.4
-
12
-
-
0027572376
-
Poly (L-lactide): A long-term degradation study in vivo. Part III. Analytical characterization
-
Pistner H., Bendix D.R., Muhling J., and Reuther J.F. Poly (L-lactide): A long-term degradation study in vivo. Part III. Analytical characterization. Biomaterials 14 (1993) 291-298
-
(1993)
Biomaterials
, vol.14
, pp. 291-298
-
-
Pistner, H.1
Bendix, D.R.2
Muhling, J.3
Reuther, J.F.4
-
13
-
-
33749370435
-
Accelerated repair of a bone defect with a synthetic biodegradable bone-inducing implant
-
Matsushita N., Terai H., Okada T., et al. Accelerated repair of a bone defect with a synthetic biodegradable bone-inducing implant. J Orthop Sci 11 (2006) 505-511
-
(2006)
J Orthop Sci
, vol.11
, pp. 505-511
-
-
Matsushita, N.1
Terai, H.2
Okada, T.3
-
14
-
-
0024456814
-
A rationale for assessing sports activity levels and limitations in knee disorders
-
Noyes F.R., Barber S.D., and Mooar L.A. A rationale for assessing sports activity levels and limitations in knee disorders. Clin Orthop Relat Res (1989) 238-249
-
(1989)
Clin Orthop Relat Res
, pp. 238-249
-
-
Noyes, F.R.1
Barber, S.D.2
Mooar, L.A.3
-
15
-
-
0020309029
-
Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale
-
Lysholm J., and Gilquist J. Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale. Am J Sports Med 10 (1982) 150-154
-
(1982)
Am J Sports Med
, vol.10
, pp. 150-154
-
-
Lysholm, J.1
Gilquist, J.2
-
16
-
-
0022387751
-
Rating systems in the evaluation of knee ligament injuries
-
Tegner Y., and Lysholm J. Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res (1985) 43-49
-
(1985)
Clin Orthop Relat Res
, pp. 43-49
-
-
Tegner, Y.1
Lysholm, J.2
-
17
-
-
0001016065
-
Rating scales
-
Fu F.H., Harner C.D., and Vince K.L. (Eds), Williams & Wilkins, Baltimore
-
Anderson A.F. Rating scales. In: Fu F.H., Harner C.D., and Vince K.L. (Eds). Knee surgery (1994), Williams & Wilkins, Baltimore 275-296
-
(1994)
Knee surgery
, pp. 275-296
-
-
Anderson, A.F.1
-
18
-
-
0017066289
-
Clinical diagnosis of anterior cruciate ligament instability in the athlete
-
Torg J.S., Conrad W., and Kalen V. Clinical diagnosis of anterior cruciate ligament instability in the athlete. Am J Sports Med 4 (1976) 84-93
-
(1976)
Am J Sports Med
, vol.4
, pp. 84-93
-
-
Torg, J.S.1
Conrad, W.2
Kalen, V.3
-
19
-
-
0018764657
-
Injury to the anterior cruciate ligament producing the pivot-shift sign
-
Fetto J.F., and Marshall J.L. Injury to the anterior cruciate ligament producing the pivot-shift sign. J Bone Joint Surg Am 61 (1979) 710-714
-
(1979)
J Bone Joint Surg Am
, vol.61
, pp. 710-714
-
-
Fetto, J.F.1
Marshall, J.L.2
-
20
-
-
22144486885
-
Poly-D, L-lactide interference screws for anterior cruciate ligament reconstruction
-
Barber F.A. Poly-D, L-lactide interference screws for anterior cruciate ligament reconstruction. Arthroscopy 21 (2005) 804-808
-
(2005)
Arthroscopy
, vol.21
, pp. 804-808
-
-
Barber, F.A.1
-
21
-
-
20344379411
-
Arthroscopic meniscal repair using the BioStinger
-
Barber F.A., Johnson D.H., and Halbrecht J.L. Arthroscopic meniscal repair using the BioStinger. Arthroscopy 21 (2005) 744-750
-
(2005)
Arthroscopy
, vol.21
, pp. 744-750
-
-
Barber, F.A.1
Johnson, D.H.2
Halbrecht, J.L.3
-
22
-
-
0034234702
-
Flipped patella tendon autograft ACL reconstruction with Bioscrew fixation
-
Barber F.A. Flipped patella tendon autograft ACL reconstruction with Bioscrew fixation. Arthroscopy 16 (2000) 483-490
-
(2000)
Arthroscopy
, vol.16
, pp. 483-490
-
-
Barber, F.A.1
-
23
-
-
0038558473
-
The effect of outlet fixation on tunnel widening
-
Barber F.A., Spruill B., and Sheluga M. The effect of outlet fixation on tunnel widening. Arthroscopy 19 (2003) 485-492
-
(2003)
Arthroscopy
, vol.19
, pp. 485-492
-
-
Barber, F.A.1
Spruill, B.2
Sheluga, M.3
-
24
-
-
0025328902
-
Accelerated rehabilitation after anterior cruciate ligament reconstruction
-
Shelbourne K.D., and Nitz P. Accelerated rehabilitation after anterior cruciate ligament reconstruction. Am J Sports Med 18 (1990) 292-299
-
(1990)
Am J Sports Med
, vol.18
, pp. 292-299
-
-
Shelbourne, K.D.1
Nitz, P.2
-
25
-
-
0033063718
-
Biology and clinical experience of absorbable materials in ACL fixation
-
Barber F.A. Biology and clinical experience of absorbable materials in ACL fixation. Tech Orthop 14 (1999) 34-42
-
(1999)
Tech Orthop
, vol.14
, pp. 34-42
-
-
Barber, F.A.1
-
26
-
-
33746796725
-
Long-term absorption of poly-L-lactic Acid interference screws
-
Barber F.A., and Dockery W.D. Long-term absorption of poly-L-lactic Acid interference screws. Arthroscopy 22 (2006) 820-826
-
(2006)
Arthroscopy
, vol.22
, pp. 820-826
-
-
Barber, F.A.1
Dockery, W.D.2
-
27
-
-
33748064667
-
Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws
-
Tecklenburg K., Burkart P., Hoser C., Rieger M., and Fink C. Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws. Arthroscopy 22 (2006) 993-999
-
(2006)
Arthroscopy
, vol.22
, pp. 993-999
-
-
Tecklenburg, K.1
Burkart, P.2
Hoser, C.3
Rieger, M.4
Fink, C.5
-
28
-
-
33746810984
-
False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo
-
Available online at www.arthroscopyjournal.org
-
Park M.C., and Tibone J.E. False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo. Arthroscopy 22 (2006) 911.e1-911.e4. http://www.arthroscopyjournal.org Available online at www.arthroscopyjournal.org
-
(2006)
Arthroscopy
, vol.22
-
-
Park, M.C.1
Tibone, J.E.2
-
29
-
-
33646145062
-
Comparison of in vitro and in vivo complement activation by metal and bioabsorbable screws used in anterior cruciate ligament reconstruction
-
Drogset J.O., Grontvedt T., Jessen V., Tegnander A., Mollnes T.E., and Bergh K. Comparison of in vitro and in vivo complement activation by metal and bioabsorbable screws used in anterior cruciate ligament reconstruction. Arthroscopy 22 (2006) 489-496
-
(2006)
Arthroscopy
, vol.22
, pp. 489-496
-
-
Drogset, J.O.1
Grontvedt, T.2
Jessen, V.3
Tegnander, A.4
Mollnes, T.E.5
Bergh, K.6
-
30
-
-
3042608497
-
Biomaterial resorption rate and healing site morphology of inorganic bovine bone and beta-tricalcium phosphate in the canine: A 24-month longitudinal histologic study and morphometric analysis
-
Artzi Z., Weinreb M., Givol N., et al. Biomaterial resorption rate and healing site morphology of inorganic bovine bone and beta-tricalcium phosphate in the canine: A 24-month longitudinal histologic study and morphometric analysis. Int J Oral Maxillofac Implants 19 (2004) 357-368
-
(2004)
Int J Oral Maxillofac Implants
, vol.19
, pp. 357-368
-
-
Artzi, Z.1
Weinreb, M.2
Givol, N.3
-
31
-
-
0031172250
-
Technique to control pH in vicinity of biodegrading PLA-PGA implants
-
Agrawal C.M., and Athanasiou K.A. Technique to control pH in vicinity of biodegrading PLA-PGA implants. J Biomed Mater Res 38 (1997) 105-114
-
(1997)
J Biomed Mater Res
, vol.38
, pp. 105-114
-
-
Agrawal, C.M.1
Athanasiou, K.A.2
-
32
-
-
52649112483
-
Fracture of Bilok interference screws on insertion during anterior cruciate ligament reconstruction
-
Available online at www.arthroscopyjournal.org
-
Smith C.A., Tennent T.D., Pearson S.E., and Beach W.R. Fracture of Bilok interference screws on insertion during anterior cruciate ligament reconstruction. Arthroscopy 19 (2003) e115-e117. http://www.arthroscopyjournal.org Available online at www.arthroscopyjournal.org
-
(2003)
Arthroscopy
, vol.19
-
-
Smith, C.A.1
Tennent, T.D.2
Pearson, S.E.3
Beach, W.R.4
-
33
-
-
14844307842
-
Development of a perforated biodegradable interference screw
-
Hunt P., Unterhauser F.N., Strobel M.J., and Weiler A. Development of a perforated biodegradable interference screw. Arthroscopy 21 (2005) 258-265
-
(2005)
Arthroscopy
, vol.21
, pp. 258-265
-
-
Hunt, P.1
Unterhauser, F.N.2
Strobel, M.J.3
Weiler, A.4
-
34
-
-
33745948125
-
Biological performance of a new beta-TCP/PLLA composite material for applications in spine surgery: In vitro and in vivo studies
-
Aunoble S., Clement D., Frayssinet P., Harmand M.F., and Le Huec J.C. Biological performance of a new beta-TCP/PLLA composite material for applications in spine surgery: In vitro and in vivo studies. J Biomed Mater Res A 78 (2006) 416-422
-
(2006)
J Biomed Mater Res A
, vol.78
, pp. 416-422
-
-
Aunoble, S.1
Clement, D.2
Frayssinet, P.3
Harmand, M.F.4
Le Huec, J.C.5
-
35
-
-
0036533144
-
TCP is hardly resorbed and not osteoconductive in a non-loading calvarial model
-
Handschel J., Wiesmann H.P., Stratmann U., Kleinheinz J., Meyer U., and Joos U. TCP is hardly resorbed and not osteoconductive in a non-loading calvarial model. Biomaterials 23 (2002) 1689-1695
-
(2002)
Biomaterials
, vol.23
, pp. 1689-1695
-
-
Handschel, J.1
Wiesmann, H.P.2
Stratmann, U.3
Kleinheinz, J.4
Meyer, U.5
Joos, U.6
-
36
-
-
0032967708
-
In vitro and in vivo degradation of lactic acid-based interference screws used in cruciate ligament reconstruction
-
Schwach G., and Vert M. In vitro and in vivo degradation of lactic acid-based interference screws used in cruciate ligament reconstruction. Int J Biol Macromol 25 (1999) 283-291
-
(1999)
Int J Biol Macromol
, vol.25
, pp. 283-291
-
-
Schwach, G.1
Vert, M.2
|