메뉴 건너뛰기




Volumn 23, Issue 5, 2007, Pages 476-481

Bilok Interference Screws for Anterior Cruciate Ligament Reconstruction: Clinical and Radiographic Outcomes

Author keywords

Tricalcium phosphate; Anterior cruciate ligament; Bilok; Interference screw; Patellar tendon autograft; Poly L lactide

Indexed keywords

CALCIUM PHOSPHATE; POLYLACTIDE;

EID: 34247486561     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2006.12.026     Document Type: Article
Times cited : (23)

References (36)
  • 1
    • 0028786512 scopus 로고
    • Preliminary results of an absorbable interference screw
    • Barber F.A., Elrod B.F., McGuire D.A., and Paulos L.E. Preliminary results of an absorbable interference screw. Arthroscopy 11 (1995) 537-548
    • (1995) Arthroscopy , vol.11 , pp. 537-548
    • Barber, F.A.1    Elrod, B.F.2    McGuire, D.A.3    Paulos, L.E.4
  • 2
    • 13444303976 scopus 로고    scopus 로고
    • A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws
    • Kaeding C., Farr J., Kavanaugh T., and Pedroza A. A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws. Arthroscopy 21 (2005) 147-151
    • (2005) Arthroscopy , vol.21 , pp. 147-151
    • Kaeding, C.1    Farr, J.2    Kavanaugh, T.3    Pedroza, A.4
  • 3
    • 33745808821 scopus 로고    scopus 로고
    • Arthroscopic double-bundle anterior cruciate ligament reconstruction using autogenous quadriceps tendon
    • Available online at www.arthroscopyjournal.org
    • Kim S.J., Jung K.A., and Song D.H. Arthroscopic double-bundle anterior cruciate ligament reconstruction using autogenous quadriceps tendon. Arthroscopy 22 (2006) 797.e1-797.e5. http://www.arthroscopyjournal.org Available online at www.arthroscopyjournal.org
    • (2006) Arthroscopy , vol.22
    • Kim, S.J.1    Jung, K.A.2    Song, D.H.3
  • 4
    • 0032606108 scopus 로고    scopus 로고
    • Comparison of polylactide screw and expansion bolt in bioabsorbable fixation with patellar tendon bone graft for anterior cruciate ligament rupture of the knee. A preliminary study
    • Tuompo P., Partio E.K., Jukkala-Partio K., Pohjonen T., Helevirta P., and Rokkanen P. Comparison of polylactide screw and expansion bolt in bioabsorbable fixation with patellar tendon bone graft for anterior cruciate ligament rupture of the knee. A preliminary study. Knee Surg Sports Traumatol Arthrosc 7 (1999) 296-302
    • (1999) Knee Surg Sports Traumatol Arthrosc , vol.7 , pp. 296-302
    • Tuompo, P.1    Partio, E.K.2    Jukkala-Partio, K.3    Pohjonen, T.4    Helevirta, P.5    Rokkanen, P.6
  • 5
    • 0033049022 scopus 로고    scopus 로고
    • Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
    • McGuire D.A., Barber F.A., Elrod B.F., and Paulos L.E. Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 15 (1999) 463-473
    • (1999) Arthroscopy , vol.15 , pp. 463-473
    • McGuire, D.A.1    Barber, F.A.2    Elrod, B.F.3    Paulos, L.E.4
  • 6
    • 0015588586 scopus 로고
    • Resorption rate, route, route of elimination, and ultrastructure of the implant site of polylactic acid in the abdominal wall of the rat
    • Brady J.M., Cutright D.E., Miller R.A., and Barristone G.C. Resorption rate, route, route of elimination, and ultrastructure of the implant site of polylactic acid in the abdominal wall of the rat. J Biomed Mater Res 7 (1973) 155-166
    • (1973) J Biomed Mater Res , vol.7 , pp. 155-166
    • Brady, J.M.1    Cutright, D.E.2    Miller, R.A.3    Barristone, G.C.4
  • 7
    • 0033023293 scopus 로고    scopus 로고
    • Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction
    • Warden W.H., Friedman R., Teresi L.M., and Jackson D.W. Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction. Arthroscopy 15 (1999) 474-480
    • (1999) Arthroscopy , vol.15 , pp. 474-480
    • Warden, W.H.1    Friedman, R.2    Teresi, L.M.3    Jackson, D.W.4
  • 9
    • 0034786399 scopus 로고    scopus 로고
    • Reconstruction of the anterior cruciate ligament using poly-L-lactide interference screws or titanium screws: A comparative study
    • Kotani A., and Ishii Y. Reconstruction of the anterior cruciate ligament using poly-L-lactide interference screws or titanium screws: A comparative study. Knee 8 (2001) 311-315
    • (2001) Knee , vol.8 , pp. 311-315
    • Kotani, A.1    Ishii, Y.2
  • 10
    • 0014974494 scopus 로고
    • Tissue reaction to the biodegradable polylactic acid suture
    • Cutright D.E., and Hunsuck E.E. Tissue reaction to the biodegradable polylactic acid suture. Oral Surg Oral Med Oral Pathol 31 (1971) 134-139
    • (1971) Oral Surg Oral Med Oral Pathol , vol.31 , pp. 134-139
    • Cutright, D.E.1    Hunsuck, E.E.2
  • 11
    • 0023205611 scopus 로고
    • Resorbable poly (L-lactide) plates and screws for the fixation of zygomatic fractures
    • Bos R.R.M., Boering G., Rozema F.R., and Leenslag J.W. Resorbable poly (L-lactide) plates and screws for the fixation of zygomatic fractures. J Oral Maxillofac Surg 45 (1987) 751-753
    • (1987) J Oral Maxillofac Surg , vol.45 , pp. 751-753
    • Bos, R.R.M.1    Boering, G.2    Rozema, F.R.3    Leenslag, J.W.4
  • 12
    • 0027572376 scopus 로고
    • Poly (L-lactide): A long-term degradation study in vivo. Part III. Analytical characterization
    • Pistner H., Bendix D.R., Muhling J., and Reuther J.F. Poly (L-lactide): A long-term degradation study in vivo. Part III. Analytical characterization. Biomaterials 14 (1993) 291-298
    • (1993) Biomaterials , vol.14 , pp. 291-298
    • Pistner, H.1    Bendix, D.R.2    Muhling, J.3    Reuther, J.F.4
  • 13
    • 33749370435 scopus 로고    scopus 로고
    • Accelerated repair of a bone defect with a synthetic biodegradable bone-inducing implant
    • Matsushita N., Terai H., Okada T., et al. Accelerated repair of a bone defect with a synthetic biodegradable bone-inducing implant. J Orthop Sci 11 (2006) 505-511
    • (2006) J Orthop Sci , vol.11 , pp. 505-511
    • Matsushita, N.1    Terai, H.2    Okada, T.3
  • 14
    • 0024456814 scopus 로고
    • A rationale for assessing sports activity levels and limitations in knee disorders
    • Noyes F.R., Barber S.D., and Mooar L.A. A rationale for assessing sports activity levels and limitations in knee disorders. Clin Orthop Relat Res (1989) 238-249
    • (1989) Clin Orthop Relat Res , pp. 238-249
    • Noyes, F.R.1    Barber, S.D.2    Mooar, L.A.3
  • 15
    • 0020309029 scopus 로고
    • Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale
    • Lysholm J., and Gilquist J. Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale. Am J Sports Med 10 (1982) 150-154
    • (1982) Am J Sports Med , vol.10 , pp. 150-154
    • Lysholm, J.1    Gilquist, J.2
  • 16
    • 0022387751 scopus 로고
    • Rating systems in the evaluation of knee ligament injuries
    • Tegner Y., and Lysholm J. Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res (1985) 43-49
    • (1985) Clin Orthop Relat Res , pp. 43-49
    • Tegner, Y.1    Lysholm, J.2
  • 17
    • 0001016065 scopus 로고
    • Rating scales
    • Fu F.H., Harner C.D., and Vince K.L. (Eds), Williams & Wilkins, Baltimore
    • Anderson A.F. Rating scales. In: Fu F.H., Harner C.D., and Vince K.L. (Eds). Knee surgery (1994), Williams & Wilkins, Baltimore 275-296
    • (1994) Knee surgery , pp. 275-296
    • Anderson, A.F.1
  • 18
    • 0017066289 scopus 로고
    • Clinical diagnosis of anterior cruciate ligament instability in the athlete
    • Torg J.S., Conrad W., and Kalen V. Clinical diagnosis of anterior cruciate ligament instability in the athlete. Am J Sports Med 4 (1976) 84-93
    • (1976) Am J Sports Med , vol.4 , pp. 84-93
    • Torg, J.S.1    Conrad, W.2    Kalen, V.3
  • 19
    • 0018764657 scopus 로고
    • Injury to the anterior cruciate ligament producing the pivot-shift sign
    • Fetto J.F., and Marshall J.L. Injury to the anterior cruciate ligament producing the pivot-shift sign. J Bone Joint Surg Am 61 (1979) 710-714
    • (1979) J Bone Joint Surg Am , vol.61 , pp. 710-714
    • Fetto, J.F.1    Marshall, J.L.2
  • 20
    • 22144486885 scopus 로고    scopus 로고
    • Poly-D, L-lactide interference screws for anterior cruciate ligament reconstruction
    • Barber F.A. Poly-D, L-lactide interference screws for anterior cruciate ligament reconstruction. Arthroscopy 21 (2005) 804-808
    • (2005) Arthroscopy , vol.21 , pp. 804-808
    • Barber, F.A.1
  • 21
    • 20344379411 scopus 로고    scopus 로고
    • Arthroscopic meniscal repair using the BioStinger
    • Barber F.A., Johnson D.H., and Halbrecht J.L. Arthroscopic meniscal repair using the BioStinger. Arthroscopy 21 (2005) 744-750
    • (2005) Arthroscopy , vol.21 , pp. 744-750
    • Barber, F.A.1    Johnson, D.H.2    Halbrecht, J.L.3
  • 22
    • 0034234702 scopus 로고    scopus 로고
    • Flipped patella tendon autograft ACL reconstruction with Bioscrew fixation
    • Barber F.A. Flipped patella tendon autograft ACL reconstruction with Bioscrew fixation. Arthroscopy 16 (2000) 483-490
    • (2000) Arthroscopy , vol.16 , pp. 483-490
    • Barber, F.A.1
  • 23
    • 0038558473 scopus 로고    scopus 로고
    • The effect of outlet fixation on tunnel widening
    • Barber F.A., Spruill B., and Sheluga M. The effect of outlet fixation on tunnel widening. Arthroscopy 19 (2003) 485-492
    • (2003) Arthroscopy , vol.19 , pp. 485-492
    • Barber, F.A.1    Spruill, B.2    Sheluga, M.3
  • 24
    • 0025328902 scopus 로고
    • Accelerated rehabilitation after anterior cruciate ligament reconstruction
    • Shelbourne K.D., and Nitz P. Accelerated rehabilitation after anterior cruciate ligament reconstruction. Am J Sports Med 18 (1990) 292-299
    • (1990) Am J Sports Med , vol.18 , pp. 292-299
    • Shelbourne, K.D.1    Nitz, P.2
  • 25
    • 0033063718 scopus 로고    scopus 로고
    • Biology and clinical experience of absorbable materials in ACL fixation
    • Barber F.A. Biology and clinical experience of absorbable materials in ACL fixation. Tech Orthop 14 (1999) 34-42
    • (1999) Tech Orthop , vol.14 , pp. 34-42
    • Barber, F.A.1
  • 26
    • 33746796725 scopus 로고    scopus 로고
    • Long-term absorption of poly-L-lactic Acid interference screws
    • Barber F.A., and Dockery W.D. Long-term absorption of poly-L-lactic Acid interference screws. Arthroscopy 22 (2006) 820-826
    • (2006) Arthroscopy , vol.22 , pp. 820-826
    • Barber, F.A.1    Dockery, W.D.2
  • 27
    • 33748064667 scopus 로고    scopus 로고
    • Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws
    • Tecklenburg K., Burkart P., Hoser C., Rieger M., and Fink C. Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws. Arthroscopy 22 (2006) 993-999
    • (2006) Arthroscopy , vol.22 , pp. 993-999
    • Tecklenburg, K.1    Burkart, P.2    Hoser, C.3    Rieger, M.4    Fink, C.5
  • 28
    • 33746810984 scopus 로고    scopus 로고
    • False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo
    • Available online at www.arthroscopyjournal.org
    • Park M.C., and Tibone J.E. False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo. Arthroscopy 22 (2006) 911.e1-911.e4. http://www.arthroscopyjournal.org Available online at www.arthroscopyjournal.org
    • (2006) Arthroscopy , vol.22
    • Park, M.C.1    Tibone, J.E.2
  • 29
    • 33646145062 scopus 로고    scopus 로고
    • Comparison of in vitro and in vivo complement activation by metal and bioabsorbable screws used in anterior cruciate ligament reconstruction
    • Drogset J.O., Grontvedt T., Jessen V., Tegnander A., Mollnes T.E., and Bergh K. Comparison of in vitro and in vivo complement activation by metal and bioabsorbable screws used in anterior cruciate ligament reconstruction. Arthroscopy 22 (2006) 489-496
    • (2006) Arthroscopy , vol.22 , pp. 489-496
    • Drogset, J.O.1    Grontvedt, T.2    Jessen, V.3    Tegnander, A.4    Mollnes, T.E.5    Bergh, K.6
  • 30
    • 3042608497 scopus 로고    scopus 로고
    • Biomaterial resorption rate and healing site morphology of inorganic bovine bone and beta-tricalcium phosphate in the canine: A 24-month longitudinal histologic study and morphometric analysis
    • Artzi Z., Weinreb M., Givol N., et al. Biomaterial resorption rate and healing site morphology of inorganic bovine bone and beta-tricalcium phosphate in the canine: A 24-month longitudinal histologic study and morphometric analysis. Int J Oral Maxillofac Implants 19 (2004) 357-368
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 357-368
    • Artzi, Z.1    Weinreb, M.2    Givol, N.3
  • 31
    • 0031172250 scopus 로고    scopus 로고
    • Technique to control pH in vicinity of biodegrading PLA-PGA implants
    • Agrawal C.M., and Athanasiou K.A. Technique to control pH in vicinity of biodegrading PLA-PGA implants. J Biomed Mater Res 38 (1997) 105-114
    • (1997) J Biomed Mater Res , vol.38 , pp. 105-114
    • Agrawal, C.M.1    Athanasiou, K.A.2
  • 32
    • 52649112483 scopus 로고    scopus 로고
    • Fracture of Bilok interference screws on insertion during anterior cruciate ligament reconstruction
    • Available online at www.arthroscopyjournal.org
    • Smith C.A., Tennent T.D., Pearson S.E., and Beach W.R. Fracture of Bilok interference screws on insertion during anterior cruciate ligament reconstruction. Arthroscopy 19 (2003) e115-e117. http://www.arthroscopyjournal.org Available online at www.arthroscopyjournal.org
    • (2003) Arthroscopy , vol.19
    • Smith, C.A.1    Tennent, T.D.2    Pearson, S.E.3    Beach, W.R.4
  • 33
    • 14844307842 scopus 로고    scopus 로고
    • Development of a perforated biodegradable interference screw
    • Hunt P., Unterhauser F.N., Strobel M.J., and Weiler A. Development of a perforated biodegradable interference screw. Arthroscopy 21 (2005) 258-265
    • (2005) Arthroscopy , vol.21 , pp. 258-265
    • Hunt, P.1    Unterhauser, F.N.2    Strobel, M.J.3    Weiler, A.4
  • 34
    • 33745948125 scopus 로고    scopus 로고
    • Biological performance of a new beta-TCP/PLLA composite material for applications in spine surgery: In vitro and in vivo studies
    • Aunoble S., Clement D., Frayssinet P., Harmand M.F., and Le Huec J.C. Biological performance of a new beta-TCP/PLLA composite material for applications in spine surgery: In vitro and in vivo studies. J Biomed Mater Res A 78 (2006) 416-422
    • (2006) J Biomed Mater Res A , vol.78 , pp. 416-422
    • Aunoble, S.1    Clement, D.2    Frayssinet, P.3    Harmand, M.F.4    Le Huec, J.C.5
  • 36
    • 0032967708 scopus 로고    scopus 로고
    • In vitro and in vivo degradation of lactic acid-based interference screws used in cruciate ligament reconstruction
    • Schwach G., and Vert M. In vitro and in vivo degradation of lactic acid-based interference screws used in cruciate ligament reconstruction. Int J Biol Macromol 25 (1999) 283-291
    • (1999) Int J Biol Macromol , vol.25 , pp. 283-291
    • Schwach, G.1    Vert, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.