메뉴 건너뛰기




Volumn 52, Issue 1, 2007, Pages

Electron radiotherapy: A study on dosimetric uncertainty using small cutouts

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; DOSIMETRY; ELECTRON BEAMS; LINEAR ACCELERATORS; MONTE CARLO METHODS; ONCOLOGY;

EID: 34247483222     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/52/1/N01     Document Type: Article
Times cited : (11)

References (23)
  • 1
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high energy photon and electron beams
    • Almond P R, Biggs P J, Coursey B M, Hanson W F, Huq M S, Nath R and Rogers D W 1999 AAPM's TG-51 protocol for clinical reference dosimetry of high energy photon and electron beams Med. Phys. 26 1847-70
    • (1999) Med. Phys. , vol.26 , Issue.9 , pp. 1847-1870
    • Almond, P.R.1    Biggs, P.J.2    Coursey, B.M.3    Hanson, W.F.4    Huq, M.S.5    Nath, R.6    Rogers, D.W.7
  • 2
    • 0034763445 scopus 로고    scopus 로고
    • Modeling pencil-beam divergence with the electron pencil-beam redefinition algorithm
    • Boyd R A, Hogstrom K R, White R A and Starkschall G 2001 Modeling pencil-beam divergence with the electron pencil-beam redefinition algorithm Phys. Med. Biol. 46 2841-56
    • (2001) Phys. Med. Biol. , vol.46 , Issue.11 , pp. 2841-2856
    • Boyd, R.A.1    Hogstrom, K.R.2    White, R.A.3    Starkschall, G.4
  • 3
    • 0034856752 scopus 로고    scopus 로고
    • A two-source model for electron beams: Calculation of relative output factors
    • Chen J Z, Van Dyk J, Lewis C and Battista J J 2001 A two-source model for electron beams: calculation of relative output factors Med. Phys. 28 1735-45
    • (2001) Med. Phys. , vol.28 , Issue.8 , pp. 1735-1745
    • Chen, J.Z.1    Van Dyk, J.2    Lewis, C.3    Battista, J.J.4
  • 4
    • 85024991833 scopus 로고    scopus 로고
    • Comparison between TG-51 and TG-21: Calibration of photon and electron beams in water using cylindrical chambers
    • Cho S H, Lowenstein J R, Balter P A, Wells N H and Hanson W F 2000 Comparison between TG-51 and TG-21: calibration of photon and electron beams in water using cylindrical chambers J. Appl. Clin. Med. Phys. 1 108-15
    • (2000) J. Appl. Clin. Med. Phys. , vol.1 , Issue.3 , pp. 108-115
    • Cho, S.H.1    Lowenstein, J.R.2    Balter, P.A.3    Wells, N.H.4    Hanson, W.F.5
  • 5
    • 33645412384 scopus 로고    scopus 로고
    • Experimental verification of the application of lateral build-up ratio on the 4 MeV electron beam
    • Chow J C L and Newman S 2006a Experimental verification of the application of lateral build-up ratio on the 4 MeV electron beam J. Appl. Clin. Med. Phys 7 35-41
    • (2006) J. Appl. Clin. Med. Phys , vol.7 , Issue.1 , pp. 35-41
    • Chow, J.C.L.1    Newman, S.2
  • 6
    • 33645408815 scopus 로고    scopus 로고
    • A graphical user interface for an electron monitor unit calculator using a sector-integration algorithm and exponential curve-fitting method
    • Chow J C L, Grigorov G N and MacGregor C 2006b A graphical user interface for an electron monitor unit calculator using a sector-integration algorithm and exponential curve-fitting method J. Appl. Clin. Med. Phys. 7 52-64
    • (2006) J. Appl. Clin. Med. Phys. , vol.7 , Issue.1 , pp. 52-64
    • Chow, J.C.L.1    Grigorov, G.N.2    MacGregor, C.3
  • 7
    • 33745064326 scopus 로고    scopus 로고
    • Peripheral dose outside applicators in electron beams
    • Chow J C L and Grigorov G N 2006c Peripheral dose outside applicators in electron beams Phys. Med. Biol. 51 N231-240
    • (2006) Phys. Med. Biol. , vol.51 , Issue.12
    • Chow, J.C.L.1    Grigorov, G.N.2
  • 8
    • 0030875108 scopus 로고    scopus 로고
    • Practical approach to electron beam dosimetry at extended SSD
    • Cygler J, Li X A, Ding G X and Lawrene E 1997 Practical approach to electron beam dosimetry at extended SSD Phys. Med. Biol. 42 1505-14
    • (1997) Phys. Med. Biol. , vol.42 , Issue.8 , pp. 1505-1514
    • Cygler, J.1    Li, X.A.2    Ding, G.X.3    Lawrene, E.4
  • 9
    • 24944573066 scopus 로고    scopus 로고
    • A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm
    • Ding G X, Cygler J E, Yu C W, Kalach N I and Daskalov G 2005 A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm Int. J. Radiat. Oncol. Biol. Phys. 63 622-33
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.63 , Issue.2 , pp. 622-633
    • Ding, G.X.1    Cygler, J.E.2    Yu, C.W.3    Kalach, N.I.4    Daskalov, G.5
  • 10
    • 0037833744 scopus 로고    scopus 로고
    • Electron dose calculations: A comparison of two commercial treatment planning computers
    • Glegg M M 2002 Electron dose calculations: a comparison of two commercial treatment planning computers Med. Dosim. 28 99-105
    • (2002) Med. Dosim. , vol.28 , Issue.2 , pp. 99-105
    • Glegg, M.M.1
  • 11
    • 0002836335 scopus 로고
    • Evaluation of electron pencil beam dose calculation
    • Hogstrom K R 1987 Evaluation of electron pencil beam dose calculation Radiation Oncology Physics 1986 ed J G Kereiakes, H R Elson and C G Born (New York: American Institute of Physics) pp 532-57 (AAPM Monograph vol 15)
    • (1987) Radiation Oncology Physics 1986 , pp. 532-557
    • Hogstrom, K.R.1
  • 14
    • 34247467409 scopus 로고    scopus 로고
    • Kawrakow I and Rogers D W O 2000 The EGSnrc Code system: Monte Carlo Simulation of Electron and Photon Transport NRCC Report PIPRS-701 (Ottawa: National Research Council of Canada)
    • (2000) Report PIPRS-701
    • Kawrakow, I.1    Rogers, D.W.O.2
  • 18
    • 34247471112 scopus 로고
    • ICRU 1984 Radiation dosimetry: electron beams with energies between 1 and 50 MeV ICRU Report No 35 (Bethesda, MD: International Commission on Radiation Units and Measurement) pp 91-2
    • (1984) ICRU Report No 35 , pp. 91-92
    • Icru1
  • 20
    • 0026437901 scopus 로고
    • Dosimetry of small field electron beams
    • Rustgi S N and Working K R 1992 Dosimetry of small field electron beams Med. Dosim. 17 107-10
    • (1992) Med. Dosim. , vol.17 , pp. 107-110
    • Rustgi, S.N.1    Working, K.R.2
  • 21
    • 0023574937 scopus 로고
    • Practical methods of electron depth-dose measurement compared to use of the NACP design chamber in water
    • Ten Haken R K, Fraass B A and Ronald J J 1987 Practical methods of electron depth-dose measurement compared to use of the NACP design chamber in water Med. Phys. 14 1060-6
    • (1987) Med. Phys. , vol.14 , Issue.6 , pp. 1060-1066
    • Ten Haken, R.K.1    Fraass, B.A.2    Ronald, J.J.3
  • 22
    • 0034974992 scopus 로고    scopus 로고
    • Monte Carlo calculation of output factors for circular, rectangular and square fields of electron accelerators (6-20 MeV)
    • Verhaegen F, Mubata C, Pettingell J, Bidmead A M, Rosenberg I, Mickridge D and Nahum A E 2001 Monte Carlo calculation of output factors for circular, rectangular and square fields of electron accelerators (6-20 MeV) Med. Phys. 28 938-49
    • (2001) Med. Phys. , vol.28 , Issue.6 , pp. 938-949
    • Verhaegen, F.1    Mubata, C.2    Pettingell, J.3    Bidmead, A.M.4    Rosenberg, I.5    Mickridge, D.6    Nahum, A.E.7
  • 23
    • 0032957195 scopus 로고    scopus 로고
    • Monte Carlo investigation of electron beam output factors versus size of square cutout
    • Zhang G G, Rogers D W, Cygler J E and Mackie T R 1999 Monte Carlo investigation of electron beam output factors versus size of square cutout Med. Phys. 26 743-50
    • (1999) Med. Phys. , vol.26 , Issue.5 , pp. 743-750
    • Zhang, G.G.1    Rogers, D.W.2    Cygler, J.E.3    MacKie, T.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.