메뉴 건너뛰기




Volumn 6454, Issue , 2007, Pages

Singlet oxygen generator on a chip for MEMS-based COIL

Author keywords

COIL; MEMS; Microelectromechanical systems; Singlet oxygen generator

Indexed keywords

CAPILLARY EFFECTS; HEAT OF REACTION; SINGLET OXYGEN GENERATOR;

EID: 34247399082     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.707205     Document Type: Conference Paper
Times cited : (1)

References (7)
  • 1
    • 3943069760 scopus 로고    scopus 로고
    • Design of a MEMS-Based microChemical Oxygen-Iodine Laser (μCOIL) System
    • B. A. Wilhite et al., "Design of a MEMS-Based microChemical Oxygen-Iodine Laser (μCOIL) System," IEEE J. Quantum Electronics, 40(8), 1041-1055 (2004).
    • (2004) IEEE J. Quantum Electronics , vol.40 , Issue.8 , pp. 1041-1055
    • Wilhite, B.A.1
  • 2
    • 14044250011 scopus 로고    scopus 로고
    • Micromixing of Miscible Liquids in Segmented Gas-Liquid Flow
    • A. Gunther et al., "Micromixing of Miscible Liquids in Segmented Gas-Liquid Flow," Langmuir, 21(4), 1547-1555 (2005).
    • (2005) Langmuir , vol.21 , Issue.4 , pp. 1547-1555
    • Gunther, A.1
  • 3
    • 18644369507 scopus 로고    scopus 로고
    • g) generated by a microwave discharge in a subsonic-flow reactor, Appl. Phys. Lett. 86, 051105 (2005).
    • g) generated by a microwave discharge in a subsonic-flow reactor," Appl. Phys. Lett. 86, 051105 (2005).
  • 4
    • 0000232166 scopus 로고    scopus 로고
    • g) (0,0) transition: A comparison of cavity ringdown and high resolution Fourier transform spectroscopy with a long-path absorption cell
    • g) (0,0) transition: A comparison of cavity ringdown and high resolution Fourier transform spectroscopy with a long-path absorption cell," V. Chem. Phys. 110, 10749 (1999).
    • (1999) V. Chem. Phys , vol.110 , pp. 10749
    • Newman, S.M.1
  • 6
    • 0003650607 scopus 로고
    • The Standard Chemical Oxgen-Iodine Laser Kinetic Package
    • G.P. Perram and G.D. Hager, "The Standard Chemical Oxgen-Iodine Laser Kinetic Package," AFWL-TR-88-50 (1988).
    • (1988) AFWL-TR-88-50
    • Perram, G.P.1    Hager, G.D.2
  • 7
    • 0032224402 scopus 로고    scopus 로고
    • Quantitative Determination of Oxygen Yield in a Chemical Oxygen-Iodine Laser
    • Kendrick, K.R., C.A. Helms, B. Quillen and R.J. Copland, "Quantitative Determination of Oxygen Yield in a Chemical Oxygen-Iodine Laser." SPIE 3268, 125-129 (1998).
    • (1998) SPIE 3268 , pp. 125-129
    • Kendrick, K.R.1    Helms, C.A.2    Quillen, B.3    Copland, R.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.