메뉴 건너뛰기




Volumn 25, Issue 4, 2007, Pages 509-512

Three-dimensional fluid pressure mapping in porous media using magnetic resonance imaging with gas-filled liposomes

Author keywords

Contrast agent; Liposome; Microbubble; MRI; Porous medium; Pressure

Indexed keywords

GLYCEROL; LIPOSOME; METHYLCELLULOSE; SILICA GEL;

EID: 34247398783     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2006.11.021     Document Type: Article
Times cited : (9)

References (7)
  • 1
    • 0034928381 scopus 로고    scopus 로고
    • Direct measurement of porous media local hydrodynamical permeability using gas MRI
    • Bencsik M., and Ramanathan C. Direct measurement of porous media local hydrodynamical permeability using gas MRI. Magn Reson Imaging 19 3-4 (2001) 379-383
    • (2001) Magn Reson Imaging , vol.19 , Issue.3-4 , pp. 379-383
    • Bencsik, M.1    Ramanathan, C.2
  • 3
    • 0028321471 scopus 로고
    • Microscopic susceptibility variation and transverse relaxation: theory and experiment
    • Weisskoff R.M., Zuo C.S., Boxerman J.L., and Rosen B.R. Microscopic susceptibility variation and transverse relaxation: theory and experiment. Magn Reson Med 31 (1994) 601-610
    • (1994) Magn Reson Med , vol.31 , pp. 601-610
    • Weisskoff, R.M.1    Zuo, C.S.2    Boxerman, J.L.3    Rosen, B.R.4
  • 4
    • 0001314549 scopus 로고
    • Conditions for initial Quasilinear T2-1 versus τ for Carr-Purcell-Meiboom-Gill NMR with diffusion and susceptibility differences in porous media and tissues
    • Brown R.J.S., and Fantazzini P. Conditions for initial Quasilinear T2-1 versus τ for Carr-Purcell-Meiboom-Gill NMR with diffusion and susceptibility differences in porous media and tissues. Phys Rev B 47 (1993) 14823-14834
    • (1993) Phys Rev B , vol.47 , pp. 14823-14834
    • Brown, R.J.S.1    Fantazzini, P.2
  • 5
    • 0036158537 scopus 로고    scopus 로고
    • On the parameters affecting the sensitivity of MR measures of pressure with microbubbles
    • Dharmakumar R., Plewes D.B., and Wright G.A. On the parameters affecting the sensitivity of MR measures of pressure with microbubbles. Magn Reson Med 47 (2000) 264-273
    • (2000) Magn Reson Med , vol.47 , pp. 264-273
    • Dharmakumar, R.1    Plewes, D.B.2    Wright, G.A.3
  • 6
    • 34247382327 scopus 로고    scopus 로고
    • Unger EC, Evan C, Low density microspheres and their use as contrast agents for computed tomography, US Patent 5,205,290, 1991.
  • 7
    • 0344527887 scopus 로고    scopus 로고
    • Targeted delivery of gas-filled microspheres, contrast agents for ultrasound imaging
    • Klibanov A.L. Targeted delivery of gas-filled microspheres, contrast agents for ultrasound imaging. Adv Drug Deliv Rev 37 (1999) 139-157
    • (1999) Adv Drug Deliv Rev , vol.37 , pp. 139-157
    • Klibanov, A.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.