메뉴 건너뛰기




Volumn 221, Issue 3, 2007, Pages 190-194

The influence of low to moderate myopia on retinal nerve fiber layer as assessed by scanning laser polarimetry with variable corneal compensator

Author keywords

Fixed corneal compensator; Myopia; Retinal nerve fiber layer; Variable corneal compensator

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; CORNEA; DEVICE; DISEASE PREDISPOSITION; DISEASE SEVERITY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MYOPIA; NERVE FIBER; NEUROLOGIC EXAMINATION; OPEN ANGLE GLAUCOMA; PARAMETER; PERIMETRY; RETINA; RISK FACTOR; SCANNING LASER POLARIMETRY; VARIABLE CORNEAL COMPENSATOR;

EID: 34247370584     PISSN: 00303755     EISSN: None     Source Type: Journal    
DOI: 10.1159/000099300     Document Type: Article
Times cited : (7)

References (30)
  • 1
    • 0001188112 scopus 로고
    • Spatially resolved birefringence of the retinal nerve fiber layer assessed with a retinal laser ellipsometer
    • Dreher AW, Reiter K, Weinreb RN: Spatially resolved birefringence of the retinal nerve fiber layer assessed with a retinal laser ellipsometer. Appl Opt 1992;31:3730-3735.
    • (1992) Appl Opt , vol.31 , pp. 3730-3735
    • Dreher, A.W.1    Reiter, K.2    Weinreb, R.N.3
  • 2
    • 0025329536 scopus 로고
    • Histopathologic validation of Fourier-ellipsometry measurement of retinal nerve fiber layer thickness
    • Weinreb RN, Dreher AW, Coleman A, Quigley H, Shaw B, Reiter K: Histopathologic validation of Fourier-ellipsometry measurement of retinal nerve fiber layer thickness. Arch Ophthalmol 1990;108:557-560.
    • (1990) Arch Ophthalmol , vol.108 , pp. 557-560
    • Weinreb, R.N.1    Dreher, A.W.2    Coleman, A.3    Quigley, H.4    Shaw, B.5    Reiter, K.6
  • 3
    • 0028864556 scopus 로고
    • Association between quantitative nerve fiber layer measurement and visual field loss in glaucoma
    • Weinreb RN, Shakiba S, Sample PA, et al: Association between quantitative nerve fiber layer measurement and visual field loss in glaucoma. Am J Ophthalmol 1995;120:732-738.
    • (1995) Am J Ophthalmol , vol.120 , pp. 732-738
    • Weinreb, R.N.1    Shakiba, S.2    Sample, P.A.3
  • 5
    • 0031049984 scopus 로고    scopus 로고
    • The sensitivity and specificity of nerve fiber layer measurements in glaucoma as determined with scanning laser polarimetry
    • Tjon-Fo-Sang MJ, Lemij HG: The sensitivity and specificity of nerve fiber layer measurements in glaucoma as determined with scanning laser polarimetry. Am J Ophthalmol 1997;123:62-69.
    • (1997) Am J Ophthalmol , vol.123 , pp. 62-69
    • Tjon-Fo-Sang, M.J.1    Lemij, H.G.2
  • 7
    • 0029741678 scopus 로고    scopus 로고
    • Measurement by nerve fiber analyzer of retinal nerve fiber layer thickness in normal subjects and patients with ocular hypertension
    • Tjon-Fo-Sang MJ, de Vries J, Lemij HG: Measurement by nerve fiber analyzer of retinal nerve fiber layer thickness in normal subjects and patients with ocular hypertension. Am J Ophthalmol 1996;122:220-227.
    • (1996) Am J Ophthalmol , vol.122 , pp. 220-227
    • Tjon-Fo-Sang, M.J.1    de Vries, J.2    Lemij, H.G.3
  • 8
    • 0029090029 scopus 로고
    • Nerve fiber thickness in diabetics and its relevance to severity of diabetic retinopathy
    • Ido T, Hayakawa T, Inazumi K: Nerve fiber thickness in diabetics and its relevance to severity of diabetic retinopathy. Folia Ophthalmol Jpn 1995;46:705-708.
    • (1995) Folia Ophthalmol Jpn , vol.46 , pp. 705-708
    • Ido, T.1    Hayakawa, T.2    Inazumi, K.3
  • 9
    • 33748470000 scopus 로고    scopus 로고
    • Nerve fiber layer polarimetry changes after argon panretinal photocoagulation in diabetic retinopathy
    • Magat-Gordon CB, Carney MD, Tabassian AR, Allen RC: Nerve fiber layer polarimetry changes after argon panretinal photocoagulation in diabetic retinopathy. ARVO 1999;40.
    • (1999) ARVO , pp. 40
    • Magat-Gordon, C.B.1    Carney, M.D.2    Tabassian, A.R.3    Allen, R.C.4
  • 10
    • 33748473284 scopus 로고    scopus 로고
    • Demyelinating optic neuritis: Longitudinal changes in the retinal nerve fiber layer measured by the scanning laser polarimeter
    • Ling RHL, Shuttleworth GN, Steele DHW, Khong CH, Potts MJ: Demyelinating optic neuritis: longitudinal changes in the retinal nerve fiber layer measured by the scanning laser polarimeter. ARVO 1999;40.
    • (1999) ARVO , pp. 40
    • Ling, R.H.L.1    Shuttleworth, G.N.2    Steele, D.H.W.3    Khong, C.H.4    Potts, M.J.5
  • 13
    • 33748475569 scopus 로고    scopus 로고
    • Effect of cataract extraction with intraocular lens (IOL) implantation on scanning laser polarimetry (NFA/GDx) measurement of retinal nerve fiber layer (RNFL) thickness
    • Blom DPC, Cameron BD, Eisenberg ER, Clements P: Effect of cataract extraction with intraocular lens (IOL) implantation on scanning laser polarimetry (NFA/GDx) measurement of retinal nerve fiber layer (RNFL) thickness. ARVO 1999;40.
    • (1999) ARVO , pp. 40
    • Blom, D.P.C.1    Cameron, B.D.2    Eisenberg, E.R.3    Clements, P.4
  • 14
    • 2442462210 scopus 로고    scopus 로고
    • Effect of cataract surgery and foldable lens implantation on retinal nerve fiber layer thickness as measured by scanning laser polarimetry with variable corneal compensator
    • Vetrugno M, Trabucco T, Sisto D, Sborgia C: Effect of cataract surgery and foldable lens implantation on retinal nerve fiber layer thickness as measured by scanning laser polarimetry with variable corneal compensator. Eur J Ophthalmol 2004;14:106-110.
    • (2004) Eur J Ophthalmol , vol.14 , pp. 106-110
    • Vetrugno, M.1    Trabucco, T.2    Sisto, D.3    Sborgia, C.4
  • 15
    • 0033858678 scopus 로고    scopus 로고
    • Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry
    • Greenfield DS, Knighton RW, Huang XR: Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry. Am J Ophthalmol 2000;129:715-722.
    • (2000) Am J Ophthalmol , vol.129 , pp. 715-722
    • Greenfield, D.S.1    Knighton, R.W.2    Huang, X.R.3
  • 16
    • 0037358653 scopus 로고    scopus 로고
    • Normative retardation data corrected for the corneal polarization axis with scanning laser polarimetry
    • Greenfield DS, Knighton RW, Feuer WJ, et al: Normative retardation data corrected for the corneal polarization axis with scanning laser polarimetry. Ophthalmic Surg Lasers Imaging 2003;34:165-171.
    • (2003) Ophthalmic Surg Lasers Imaging , vol.34 , pp. 165-171
    • Greenfield, D.S.1    Knighton, R.W.2    Feuer, W.J.3
  • 17
    • 0242668741 scopus 로고    scopus 로고
    • Effect of individual compensation for anterior segment birefringence on retinal nerve fiber layer assessments as determined by scanning laser polarimetry
    • Choplin NT, Zhou Q, Knighton RW: Effect of individual compensation for anterior segment birefringence on retinal nerve fiber layer assessments as determined by scanning laser polarimetry. Ophthalmology 2003;110:719-725.
    • (2003) Ophthalmology , vol.110 , pp. 719-725
    • Choplin, N.T.1    Zhou, Q.2    Knighton, R.W.3
  • 18
    • 0037314187 scopus 로고    scopus 로고
    • Glaucoma detection using scanning laser polarimetry with variable corneal compensation
    • Weinreb RN, Bowd C, Zangwill LM: Glaucoma detection using scanning laser polarimetry with variable corneal compensation. Arch Ophthalmol 2003;121:218-224.
    • (2003) Arch Ophthalmol , vol.121 , pp. 218-224
    • Weinreb, R.N.1    Bowd, C.2    Zangwill, L.M.3
  • 19
    • 0036291707 scopus 로고    scopus 로고
    • Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetry
    • Greenfield DS, Knighton RW, Feuer WJ, et al: Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetry. Am J Ophthalmol 2002;134:27-33.
    • (2002) Am J Ophthalmol , vol.134 , pp. 27-33
    • Greenfield, D.S.1    Knighton, R.W.2    Feuer, W.J.3
  • 20
    • 0842310446 scopus 로고    scopus 로고
    • Variable corneal compensation improves discrimination between normal and glaucomatous eyes with the scanning laser polarimeter
    • Tannenbaum DP, Hoffman BA, Lemij HG, et al: Variable corneal compensation improves discrimination between normal and glaucomatous eyes with the scanning laser polarimeter. Ophthalmology 2004;111:259-264.
    • (2004) Ophthalmology , vol.111 , pp. 259-264
    • Tannenbaum, D.P.1    Hoffman, B.A.2    Lemij, H.G.3
  • 22
    • 18844365902 scopus 로고    scopus 로고
    • Retinal nerve fiber analysis in subjects with hyperopia and anisometropic amblyopia
    • Atilla H, Batioglu F, Erkam N: Retinal nerve fiber analysis in subjects with hyperopia and anisometropic amblyopia. Binocul Vis Strabismus Q 2005;20:33-37.
    • (2005) Binocul Vis Strabismus Q , vol.20 , pp. 33-37
    • Atilla, H.1    Batioglu, F.2    Erkam, N.3
  • 23
    • 1642618110 scopus 로고    scopus 로고
    • Scanning laser polarimetry in normal subjects and patients with myopia
    • Ozdek SC, Onol M, Gurelik G, Hasanreisoglu B: Scanning laser polarimetry in normal subjects and patients with myopia. Br J Ophthalmol 2000;84:264-267.
    • (2000) Br J Ophthalmol , vol.84 , pp. 264-267
    • Ozdek, S.C.1    Onol, M.2    Gurelik, G.3    Hasanreisoglu, B.4
  • 24
    • 0031051999 scopus 로고    scopus 로고
    • Severe myopia as a risk factor for progressive visual field loss in primary open-angle glaucoma
    • Chihara E, Liu X, Dong I, et al: Severe myopia as a risk factor for progressive visual field loss in primary open-angle glaucoma. Ophthalmologica 1997;211:66-71.
    • (1997) Ophthalmologica , vol.211 , pp. 66-71
    • Chihara, E.1    Liu, X.2    Dong, I.3
  • 26
    • 0033211071 scopus 로고    scopus 로고
    • The relationship between glaucoma and myopia: The Blue Mountains Eye Study
    • Mitchell P, Hourihan F, Sandbach J, Wang JJ: The relationship between glaucoma and myopia: the Blue Mountains Eye Study. Ophthalmology 2000;106:2010-2015.
    • (2000) Ophthalmology , vol.106 , pp. 2010-2015
    • Mitchell, P.1    Hourihan, F.2    Sandbach, J.3    Wang, J.J.4
  • 27
    • 33748444743 scopus 로고    scopus 로고
    • Is there still a clinical use for scanning laser polarimetry with fixed corneal compensator?
    • Vetrugno M: Is there still a clinical use for scanning laser polarimetry with fixed corneal compensator? Ophthalmologica 2006;220:296-301.
    • (2006) Ophthalmologica , vol.220 , pp. 296-301
    • Vetrugno, M.1
  • 29
    • 34247329152 scopus 로고
    • La miopia. Clinica e terapia. Firenze, USES Edizioni scientifiche Firenze, Italian translation from: The Myopias: Basic Science and Clinical Management. Philadelphia, Harper & Row
    • Curtin BJ: Natura della miopia fisiologica e intermedia; in La miopia. Clinica e terapia. Firenze, USES Edizioni scientifiche Firenze, 1988. Italian translation from: The Myopias: Basic Science and Clinical Management. Philadelphia, Harper & Row, 1985.
    • (1985) Natura della miopia fisiologica e intermedia
    • Curtin, B.J.1
  • 30
    • 34247331518 scopus 로고
    • Weitere Beitrage zur Anatomie des myopischen Auges
    • Heine L: Weitere Beitrage zur Anatomie des myopischen Auges. Arch Augenheilkd 1900;40:160-169.
    • (1900) Arch Augenheilkd , vol.40 , pp. 160-169
    • Heine, L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.