메뉴 건너뛰기




Volumn 54, Issue 5, 2007, Pages 863-873

Endothelial cell electrical impedance parameter artifacts produced by a gold electrode and phase sensitive detection

Author keywords

Biological cells; Biomedical transducers; Impedance; Measurement errors; Parameter estimation

Indexed keywords

BIOLOGICAL CELLS; BIOMEDICAL TRANSDUCERS; CIRCUIT CAPACITANCES; INSTRUMENTAL CIRCUIT MODELS;

EID: 34247348292     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2007.893468     Document Type: Article
Times cited : (13)

References (28)
  • 1
    • 2142846185 scopus 로고
    • Monitoring fibroblast behavior in tissue culture with an applied electric field
    • I. Giaever and C. R. Keese, "Monitoring fibroblast behavior in tissue culture with an applied electric field," Proc. Nat. Acad. Sci. USA, vol. 81, pp. 3761-3764, 1984.
    • (1984) Proc. Nat. Acad. Sci. USA , vol.81 , pp. 3761-3764
    • Giaever, I.1    Keese, C.R.2
  • 2
    • 0022559399 scopus 로고
    • Use of electric fields to monitor the dynamical aspect of cell behavior in tissue culture
    • _, "Use of electric fields to monitor the dynamical aspect of cell behavior in tissue culture," IEEE Trans. Biomed. Eng., vol. BME-33, pp. 242-247, 1986.
    • (1986) IEEE Trans. Biomed. Eng , vol.BME-33 , pp. 242-247
    • Giaever, I.1    Keese, C.R.2
  • 3
    • 0028446185 scopus 로고
    • A biosensor that monitors cell morphology with electrical fields
    • Jun.-Jul
    • C. R. Keese and I. Giaever, "A biosensor that monitors cell morphology with electrical fields," IEEE Eng. Med. Biol., vol. 13, no. 3, pp. 402-408, Jun.-Jul. 1994.
    • (1994) IEEE Eng. Med. Biol , vol.13 , Issue.3 , pp. 402-408
    • Keese, C.R.1    Giaever, I.2
  • 5
    • 18744381818 scopus 로고    scopus 로고
    • Measurements of endothelial cell-to-cell and cell-to-substrate gaps and micromechanical properties of endothelial cells during monocyte adhesion
    • N. Kataoka, K. Iwaki, K. Hashimoto, S. Mochizuki, Y. Ogasawara, M. Sato, K. Tsujioka, and F. Kajiya, "Measurements of endothelial cell-to-cell and cell-to-substrate gaps and micromechanical properties of endothelial cells during monocyte adhesion," Proc. Nat. Acad. Sci., vol. 99, pp. 15638-15643, 2002.
    • (2002) Proc. Nat. Acad. Sci , vol.99 , pp. 15638-15643
    • Kataoka, N.1    Iwaki, K.2    Hashimoto, K.3    Mochizuki, S.4    Ogasawara, Y.5    Sato, M.6    Tsujioka, K.7    Kajiya, F.8
  • 8
    • 0027178669 scopus 로고
    • The effect of histamine and cyclic adenosine monophosphate on myosin light chain phophorlylation in human umbilical vein endothelial cells
    • A. B. Moy, B. Scott, S. Shasby, and D. M. Shasby, "The effect of histamine and cyclic adenosine monophosphate on myosin light chain phophorlylation in human umbilical vein endothelial cells," J. Clin. Invest., vol. 92, pp. 1198-1206, 1993.
    • (1993) J. Clin. Invest , vol.92 , pp. 1198-1206
    • Moy, A.B.1    Scott, B.2    Shasby, S.3    Shasby, D.M.4
  • 11
    • 34547370384 scopus 로고    scopus 로고
    • Real time monitoring of endothelial cell actin filament disruption by cytochalasin d using a cellular impedance biosensor
    • presented at the, Summer School Symp. Medical Devices and Biosensors ISSSMDBS, Hong Kong
    • V. NandaKumar, A. E. English, A. B. Moy, M. Mahfouz, R. Ward, K. Kruse, S. Kirkpatrick, and M. H. Goldman, "Real time monitoring of endothelial cell actin filament disruption by cytochalasin d using a cellular impedance biosensor," presented at the 2nd IEEE-EMBS Int. Summer School Symp. Medical Devices and Biosensors (ISSSMDBS), 2004, Hong Kong.
    • (2004) 2nd IEEE-EMBS Int
    • NandaKumar, V.1    English, A.E.2    Moy, A.B.3    Mahfouz, M.4    Ward, R.5    Kruse, K.6    Kirkpatrick, S.7    Goldman, M.H.8
  • 13
    • 0034012304 scopus 로고    scopus 로고
    • Spatial variations in endothelial barrier function in disturbed flows in vitro
    • J. E. Phelps and N. DePaola, "Spatial variations in endothelial barrier function in disturbed flows in vitro," Am. J. Physiol. Heart Circ. Physiol., vol. 278, pp. H469-H476, 2000.
    • (2000) Am. J. Physiol. Heart Circ. Physiol , vol.278
    • Phelps, J.E.1    DePaola, N.2
  • 14
    • 0035368773 scopus 로고    scopus 로고
    • Ca2+ signalling and pkca activate increased endothelial permeability by disassembly of ve-cadherin junctions
    • R. Sandoval, A. B. Malik, R. D. Minshall, P. Kouklis, C. A. Ellis, and A. Tiruppathi, "Ca2+ signalling and pkca activate increased endothelial permeability by disassembly of ve-cadherin junctions," J. Physiol., vol. 533, pp. 433-445, 2001.
    • (2001) J. Physiol , vol.533 , pp. 433-445
    • Sandoval, R.1    Malik, A.B.2    Minshall, R.D.3    Kouklis, P.4    Ellis, C.A.5    Tiruppathi, A.6
  • 15
    • 0026738687 scopus 로고
    • Electrical method for detection of endothelial cell shape change in real time: Assessment of endothelial barrier function
    • C. Tiruppathi, A. B. Malik, P. J. D. Vecchio, C. R. Keese, and I. Giaever, "Electrical method for detection of endothelial cell shape change in real time: Assessment of endothelial barrier function," Proc. Nat. Acad. Sci. USA, vol. 89, pp. 7919-7923, 1992.
    • (1992) Proc. Nat. Acad. Sci. USA , vol.89 , pp. 7919-7923
    • Tiruppathi, C.1    Malik, A.B.2    Vecchio, P.J.D.3    Keese, C.R.4    Giaever, I.5
  • 16
    • 0034714440 scopus 로고    scopus 로고
    • Electric cell-substrate impedance sensing (ecis) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces
    • J. Wegener, C. R. Keese, and I. Giaever, "Electric cell-substrate impedance sensing (ecis) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces," Exp. Cell Res., vol. 259, pp. 158-166, 2000.
    • (2000) Exp. Cell Res , vol.259 , pp. 158-166
    • Wegener, J.1    Keese, C.R.2    Giaever, I.3
  • 17
    • 0037086386 scopus 로고    scopus 로고
    • An in-depth analysis of electric cell-substrate impedance sensing to study the attachment and spreading of mammalian cells
    • C. Xiao, B. Lachance, G. Sunahara, and J. H. T. Luong, "An in-depth analysis of electric cell-substrate impedance sensing to study the attachment and spreading of mammalian cells," Anal. Chem., vol. 74, pp. 1333-1339, 2002.
    • (2002) Anal. Chem , vol.74 , pp. 1333-1339
    • Xiao, C.1    Lachance, B.2    Sunahara, G.3    Luong, J.H.T.4
  • 18
    • 0025916059 scopus 로고
    • Micromotion of mammalian cells measured electrically
    • I. Giaever and C. R. Keese, "Micromotion of mammalian cells measured electrically," Proc. Nat. Acad. Sci. USA, vol. 88, pp. 7896-7900, 1991.
    • (1991) Proc. Nat. Acad. Sci. USA , vol.88 , pp. 7896-7900
    • Giaever, I.1    Keese, C.R.2
  • 19
    • 0027500573 scopus 로고
    • Correction: Micromotion of mammalian cells measured electrically
    • _, "Correction: Micromotion of mammalian cells measured electrically," Proc. Natl. Acad. Sci. USA, vol. 90, p. 1634, 1993.
    • (1993) Proc. Natl. Acad. Sci. USA , vol.90 , pp. 1634
    • Giaever, I.1    Keese, C.R.2
  • 20
    • 0028823011 scopus 로고
    • Impedance analysis of mdck cells measured by electric cell-substrate impedance sensing
    • C.-M. Lo, C. R. Keese, and I. Giaever, "Impedance analysis of mdck cells measured by electric cell-substrate impedance sensing," Biophys. J., vol. 69, pp. 2800-2807, 1995.
    • (1995) Biophys. J , vol.69 , pp. 2800-2807
    • Lo, C.-M.1    Keese, C.R.2    Giaever, I.3
  • 21
    • 23944461499 scopus 로고    scopus 로고
    • Modeling error and stability of endothelial cytoskeletal-membrane parameters based on numerical modeling transendothelial impedance as resistor and capacitor in series
    • J. E. Bodmer, A. English, M. Brady, K. Blackwell, K. Haxinasto, S. Fotedar, K. Borgman, E.-W. Bai, and A. B. Moy, "Modeling error and stability of endothelial cytoskeletal-membrane parameters based on numerical modeling transendothelial impedance as resistor and capacitor in series," Am. J. Phys., vol. 289, pp. C735-C747, 2005.
    • (2005) Am. J. Phys , vol.289
    • Bodmer, J.E.1    English, A.2    Brady, M.3    Blackwell, K.4    Haxinasto, K.5    Fotedar, S.6    Borgman, K.7    Bai, E.-W.8    Moy, A.B.9
  • 24
    • 0030614375 scopus 로고    scopus 로고
    • Historical evolution of circuit models for the electrode-electrolyte interface
    • L. A. Geddes, "Historical evolution of circuit models for the electrode-electrolyte interface," Ann. Biomed. Eng., vol. 25, pp. 1-14, 1997.
    • (1997) Ann. Biomed. Eng , vol.25 , pp. 1-14
    • Geddes, L.A.1
  • 28
    • 0003987266 scopus 로고
    • Lock-In Amplifiers: Principles and Applications
    • London, U.K, Peter Peregrinus/IEE
    • M. L. Meade, Lock-In Amplifiers: Principles and Applications, ser. Iee electrical measurement series. London, U.K.: Peter Peregrinus/IEE, 1983.
    • (1983) ser. Iee electrical measurement series
    • Meade, M.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.