메뉴 건너뛰기




Volumn 35, Issue 5, 2007, Pages 1307-1311

Effect of lower limb compression devices on thermodilution cardiac output measurement

Author keywords

Cardiac output; Critical care; Deep venous thrombosis; Hemodynamic monitoring; Intensive care unit; Prophylaxis; Pulmonary artery catheter; Pulse contour analysis; Sequential compression device; Thermodilution

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; DEVICE; HEART OUTPUT; HEART OUTPUT MEASUREMENT; HEMODYNAMIC MONITORING; HUMAN; INTENSIVE CARE UNIT; LEG; LEG COMPRESSION; NEUROSURGERY; PRIORITY JOURNAL; PROSPECTIVE STUDY; PULMONARY ARTERY CATHETER; SEQUENTIAL COMPRESSION DEVICE; SURGICAL WARD; THERMODILUTION; UNIVERSITY HOSPITAL;

EID: 34247336920     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.CCM.0000262387.37554.2E     Document Type: Article
Times cited : (9)

References (24)
  • 1
    • 0000003630 scopus 로고
    • Measurement of cardiac output in anaesthetized animals by a thermodilution method
    • Fegler G: Measurement of cardiac output in anaesthetized animals by a thermodilution method. J Exp Physiol 1954; 39:153-164
    • (1954) J Exp Physiol , vol.39 , pp. 153-164
    • Fegler, G.1
  • 2
    • 0018820333 scopus 로고
    • Determination of cardiac output by thermodilution during hypothermia
    • Merrick SH, Hessel EA Jr, Dillard DH: Determination of cardiac output by thermodilution during hypothermia. Am J Cardiol 1980; 46:419-422
    • (1980) Am J Cardiol , vol.46 , pp. 419-422
    • Merrick, S.H.1    Hessel Jr, E.A.2    Dillard, D.H.3
  • 3
    • 0015291993 scopus 로고
    • Measurement of blood flow by thermodilution
    • Ganz W, Swan HJ: Measurement of blood flow by thermodilution. Am J Cardiol 1972; 29:241-246
    • (1972) Am J Cardiol , vol.29 , pp. 241-246
    • Ganz, W.1    Swan, H.J.2
  • 4
    • 0016813472 scopus 로고
    • Clinical applications of thermodilution cardiac output determinations
    • Weisel RD, Vito L, Dennis RC, et al: Clinical applications of thermodilution cardiac output determinations. Am J Surg 1975; 129:449-454
    • (1975) Am J Surg , vol.129 , pp. 449-454
    • Weisel, R.D.1    Vito, L.2    Dennis, R.C.3
  • 5
    • 0032499904 scopus 로고    scopus 로고
    • Pulmonary embolism
    • Goldhaber SZ: Pulmonary embolism. N Engl J Med 1998; 339:93-104
    • (1998) N Engl J Med , vol.339 , pp. 93-104
    • Goldhaber, S.Z.1
  • 6
    • 33646859471 scopus 로고    scopus 로고
    • Pulmonary Artery Catheter versus Central Venous Catheter to Guide Treatment of Acute Lung Injury: The National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network
    • Pulmonary Artery Catheter versus Central Venous Catheter to Guide Treatment of Acute Lung Injury: The National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network. N Engl J Med 2006; 354:2213-2224
    • (2006) N Engl J Med , vol.354 , pp. 2213-2224
  • 7
    • 34247334880 scopus 로고    scopus 로고
    • Comparison of Two Fluid-Management Strategies in Acute Lung Injury: The National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network
    • Comparison of Two Fluid-Management Strategies in Acute Lung Injury: The National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network. N Engl J Med 2006; 354:2201-2212
    • (2006) N Engl J Med , vol.354 , pp. 2201-2212
  • 8
    • 26044460566 scopus 로고    scopus 로고
    • Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: The ESCAPE trial
    • Binanay C, Califf RM, Hasselblad V, et al: Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: The ESCAPE trial. JAMA 2005; 294:1625-1633
    • (2005) JAMA , vol.294 , pp. 1625-1633
    • Binanay, C.1    Califf, R.M.2    Hasselblad, V.3
  • 9
    • 23444461703 scopus 로고    scopus 로고
    • Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial
    • Harvey S, Harrison DA, Singer M, et al: Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial. Lancet 2005; 366:472-477
    • (2005) Lancet , vol.366 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3
  • 10
    • 0345374592 scopus 로고    scopus 로고
    • Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial
    • Richard C, Warszawski J, Anguel N, et al: Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial. JAMA 2003; 290:2713-2720
    • (2003) JAMA , vol.290 , pp. 2713-2720
    • Richard, C.1    Warszawski, J.2    Anguel, N.3
  • 11
    • 0037413466 scopus 로고    scopus 로고
    • A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
    • Sandham JD, Hull RD, Brant RF, et al: A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 2003; 348:5-14
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3
  • 12
    • 0025685462 scopus 로고
    • A multicenter study of physicians' knowledge of the pulmonary artery catheter: Pulmonary Artery Catheter Study Group
    • Iberti TJ, Fischer EP, Leibowitz AB, et al: A multicenter study of physicians' knowledge of the pulmonary artery catheter: Pulmonary Artery Catheter Study Group. JAMA 1990; 264:2928-2932
    • (1990) JAMA , vol.264 , pp. 2928-2932
    • Iberti, T.J.1    Fischer, E.P.2    Leibowitz, A.B.3
  • 13
    • 0022624639 scopus 로고
    • Misled by the wedge? The Swan-Ganz catheter and left ventricular preload
    • Raper R, Sibbald WJ: Misled by the wedge? The Swan-Ganz catheter and left ventricular preload. Chest 1986; 89:427-434
    • (1986) Chest , vol.89 , pp. 427-434
    • Raper, R.1    Sibbald, W.J.2
  • 14
    • 0034795084 scopus 로고    scopus 로고
    • Sequential compression devices can cause erroneous cardiac output measurements
    • Akinci SB, Pronovost P, Dorman T: Sequential compression devices can cause erroneous cardiac output measurements. Anesthesiology 2001; 95:1027-1028
    • (2001) Anesthesiology , vol.95 , pp. 1027-1028
    • Akinci, S.B.1    Pronovost, P.2    Dorman, T.3
  • 15
    • 0033012487 scopus 로고    scopus 로고
    • Pneumatic compression stockings increase the variability of thermodilution cardiac output measurements: Do they truly affect cardiac output?
    • Hickey R, Erian R: Pneumatic compression stockings increase the variability of thermodilution cardiac output measurements: Do they truly affect cardiac output? Crit Care Med 1999; 27:1039-1041
    • (1999) Crit Care Med , vol.27 , pp. 1039-1041
    • Hickey, R.1    Erian, R.2
  • 16
    • 0027447134 scopus 로고
    • Errors in the measurement of cardiac output by thermodilution
    • Nishikawa T, Dohi S: Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993; 40:142-153
    • (1993) Can J Anaesth , vol.40 , pp. 142-153
    • Nishikawa, T.1    Dohi, S.2
  • 17
    • 0027412923 scopus 로고
    • Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility
    • Renner LE, Morton MJ, Sakuma GY: Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility. Crit Care Med 1993; 21:586-597
    • (1993) Crit Care Med , vol.21 , pp. 586-597
    • Renner, L.E.1    Morton, M.J.2    Sakuma, G.Y.3
  • 18
    • 0020202085 scopus 로고
    • Effects of mechanical ventilation on the measurement of cardiac output by thermodilution
    • Synder JV, Powner DJ: Effects of mechanical ventilation on the measurement of cardiac output by thermodilution. Crit Care Med 1982; 10:677-682
    • (1982) Crit Care Med , vol.10 , pp. 677-682
    • Synder, J.V.1    Powner, D.J.2
  • 19
    • 0022361983 scopus 로고
    • Major errors in thermodilution cardiac output measurement during rapid volume infusion
    • Wetzel RC, Latson TW: Major errors in thermodilution cardiac output measurement during rapid volume infusion. Anesthesiology 1985; 62:684-687
    • (1985) Anesthesiology , vol.62 , pp. 684-687
    • Wetzel, R.C.1    Latson, T.W.2
  • 20
    • 0033047524 scopus 로고    scopus 로고
    • Influence of lower limb pneumatic compression on pulmonary artery temperature: Effect on cardiac output measurements
    • Horiuchi K, Johnson R, Weissman C: Influence of lower limb pneumatic compression on pulmonary artery temperature: Effect on cardiac output measurements. Crit Care Med 1999; 27:1096-1099
    • (1999) Crit Care Med , vol.27 , pp. 1096-1099
    • Horiuchi, K.1    Johnson, R.2    Weissman, C.3
  • 21
    • 0026019240 scopus 로고
    • Core-peripheral temperature gradient does not predict cardiac output or systemic vascular resistance in children
    • Butt W, Shann F: Core-peripheral temperature gradient does not predict cardiac output or systemic vascular resistance in children. Anaesth Intensive Care 1991; 19:84-87
    • (1991) Anaesth Intensive Care , vol.19 , pp. 84-87
    • Butt, W.1    Shann, F.2
  • 22
    • 12844250010 scopus 로고    scopus 로고
    • Validation study of PulseCO system for continuous cardiac output measurement
    • Berberian G, Quinn TA, Vigilance DW, et al: Validation study of PulseCO system for continuous cardiac output measurement. ASAIO J 2005; 51:37-40
    • (2005) ASAIO J , vol.51 , pp. 37-40
    • Berberian, G.1    Quinn, T.A.2    Vigilance, D.W.3
  • 23
    • 0027748318 scopus 로고
    • Hemodynamic alterations in venous blood flow produced by external pneumatic compression
    • Janssen H, Trevino C, Williams D: Hemodynamic alterations in venous blood flow produced by external pneumatic compression. J Cardiovasc Surg (Torino) 1993; 34:441-447
    • (1993) J Cardiovasc Surg (Torino) , vol.34 , pp. 441-447
    • Janssen, H.1    Trevino, C.2    Williams, D.3
  • 24
    • 0030950844 scopus 로고    scopus 로고
    • Thermodilution cardiac output measurement during simultaneous volume infusion through the venous infusion port of the pulmonary artery catheter
    • Griffin K, Benjamin E, DelGiudice R, et al: Thermodilution cardiac output measurement during simultaneous volume infusion through the venous infusion port of the pulmonary artery catheter. J Cardiothorac Vasc Anesth 1997; 11:437-439
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 437-439
    • Griffin, K.1    Benjamin, E.2    DelGiudice, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.