Volumn 6279 PART 1, Issue , 2007, Pages

Enhanced K-edge angiography utilizing a super-fluorescent x-ray generator with a gadolinium-target tube

Author keywords

Characteristic x rays; Gadolinium K lines; Iodine based contrast media; K edge angiography; Quasi monochromatic x rays

Indexed keywords

CATHODES; CONTRAST MEDIA; FLUORESCENCE; GADOLINIUM; NETWORKS (CIRCUITS); X RAY TUBES; X RAYS;

EID: 34247333446     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.725174     Document Type: Conference Paper
Times cited : (4)

References (16)
  • 1
    • 0002163129 scopus 로고
    • Some characteristics of a 600 kV flash x-ray tube
    • A. Mattsson, "Some characteristics of a 600 kV flash x-ray tube," Physica Scripta, 5, 99-102, 1972.
    • (1972) Physica Scripta , vol.5 , pp. 99-102
    • Mattsson, A.1
  • 2
    • 0018468347 scopus 로고
    • X-ray flash techniques
    • R. Germer, "X-ray flash techniques," J. Phys. E: Sci. Instrum., 12, 336-350, 1979.
    • (1979) J. Phys. E: Sci. Instrum , vol.12 , pp. 336-350
    • Germer, R.1
  • 5
    • 22944465716 scopus 로고    scopus 로고
    • Clean monochromatic x-ray irradiation from weakly ionized linear copper plasma
    • 049002-1-6
    • E. Sato, E. Tanaka, H. Mori, T. Kawai, S. Sato and K. Takayama, "Clean monochromatic x-ray irradiation from weakly ionized linear copper plasma," Opt. Eng., 44, 049002-1-6, 2005.
    • (2005) Opt. Eng , vol.44
    • Sato, E.1    Tanaka, E.2    Mori, H.3    Kawai, T.4    Sato, S.5    Takayama, K.6
  • 8
    • 12844255717 scopus 로고    scopus 로고
    • Compact monochromatic flash x-ray generator utilizing a disk-cathode molybdenum tube
    • E. Sato, E. Tanaka, H. Mori, T. Kawai, T. Ichimaru, S. Sato, K. Takayama and H. Ido, "Compact monochromatic flash x-ray generator utilizing a disk-cathode molybdenum tube," Med. Phys., 32, 49-54, 2005.
    • (2005) Med. Phys , vol.32 , pp. 49-54
    • Sato, E.1    Tanaka, E.2    Mori, H.3    Kawai, T.4    Ichimaru, T.5    Sato, S.6    Takayama, K.7    Ido, H.8
  • 13
    • 9244231786 scopus 로고    scopus 로고
    • Demonstration of enhanced K-edge angiography using a cerium target x-ray generator
    • E. Sato, E. Tanaka, H. Mori, T. Kawai, T. Ichimaru, S. Sato, K. Takayama and H. Ido, "Demonstration of enhanced K-edge angiography using a cerium target x-ray generator," Med. Phys., 31, 3017-3021, 2004.
    • (2004) Med. Phys , vol.31 , pp. 3017-3021
    • Sato, E.1    Tanaka, E.2    Mori, H.3    Kawai, T.4    Ichimaru, T.5    Sato, S.6    Takayama, K.7    Ido, H.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.