메뉴 건너뛰기




Volumn 33, Issue 5, 2007, Pages 796-799

Capsulorhexis contraction after cataract surgery: Comparison of sharp anterior edge and modified anterior edge acrylic intraocular lenses

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CAPSULORHEXIS; CAPSULORHEXIS CONTRACTION; CATARACT EXTRACTION; CONTROLLED STUDY; DENMARK; FEMALE; HUMAN; LENS CAPSULE; LENS IMPLANT; MALE; PHACOEMULSIFICATION; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY;

EID: 34247328640     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2007.01.020     Document Type: Article
Times cited : (15)

References (17)
  • 1
    • 0025021178 scopus 로고
    • Development, advantages, and methods of the continuous circular capsulorhexis technique
    • Gimbel H.V., and Neuhann T. Development, advantages, and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg 16 (1990) 31-37
    • (1990) J Cataract Refract Surg , vol.16 , pp. 31-37
    • Gimbel, H.V.1    Neuhann, T.2
  • 2
    • 0032836950 scopus 로고    scopus 로고
    • Capsule contraction after continuous curvilinear capsulorhexis: poly(methyl methacrylate) versus silicone intraocular lenses
    • Cochener B., Jacq P.-L., and Colin J. Capsule contraction after continuous curvilinear capsulorhexis: poly(methyl methacrylate) versus silicone intraocular lenses. J Cataract Refract Surg 25 (1999) 1362-1369
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1362-1369
    • Cochener, B.1    Jacq, P.-L.2    Colin, J.3
  • 3
    • 0030953868 scopus 로고    scopus 로고
    • Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation
    • Hayashi K., Hayashi H., Nakao F., and Hayashi F. Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation. Am J Ophthalmol 123 (1997) 441-447
    • (1997) Am J Ophthalmol , vol.123 , pp. 441-447
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4
  • 4
    • 0027380142 scopus 로고
    • Postoperative complications of capsulorhexis
    • Masket S. Postoperative complications of capsulorhexis. J Cataract Refract Surg 19 (1993) 721-724
    • (1993) J Cataract Refract Surg , vol.19 , pp. 721-724
    • Masket, S.1
  • 5
    • 0031664077 scopus 로고    scopus 로고
    • Measuring the anterior capsule opening after cataract surgery to assess capsule shrinkage
    • Kimura W., Yamanishi S., Kimura T., et al. Measuring the anterior capsule opening after cataract surgery to assess capsule shrinkage. J Cataract Refract Surg 24 (1998) 1235-1238
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1235-1238
    • Kimura, W.1    Yamanishi, S.2    Kimura, T.3
  • 6
    • 0036732653 scopus 로고    scopus 로고
    • Changes in the area of the anterior capsule opening after intraocular lens implantation
    • Park T.K., Chung S.K., and Baek N.H. Changes in the area of the anterior capsule opening after intraocular lens implantation. J Cataract Refract Surg 28 (2002) 1613-1617
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1613-1617
    • Park, T.K.1    Chung, S.K.2    Baek, N.H.3
  • 7
    • 0036062059 scopus 로고    scopus 로고
    • Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification
    • Buehl W., Findl O., Menapace R., et al. Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg 28 (2002) 1105-1111
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1105-1111
    • Buehl, W.1    Findl, O.2    Menapace, R.3
  • 8
    • 4444244403 scopus 로고    scopus 로고
    • Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction
    • Sacu S., Menapace R., Buehl W., et al. Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction. J Cataract Refract Surg 30 (2004) 1875-1882
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1875-1882
    • Sacu, S.1    Menapace, R.2    Buehl, W.3
  • 10
    • 0030909318 scopus 로고    scopus 로고
    • Change in capsulorhexis size after implantation of three types of intraocular lenses
    • Gonvers M., Sickenberg M., and van Melle G. Change in capsulorhexis size after implantation of three types of intraocular lenses. J Cataract Refract Surg 23 (1997) 231-238
    • (1997) J Cataract Refract Surg , vol.23 , pp. 231-238
    • Gonvers, M.1    Sickenberg, M.2    van Melle, G.3
  • 11
    • 0031471972 scopus 로고    scopus 로고
    • Anterior capsule stability in eyes with intraocular lenses made of poly(methyl methacrylate), silicone, and AcrySof
    • Ursell P.G., Spalton D.J., and Pande M.V. Anterior capsule stability in eyes with intraocular lenses made of poly(methyl methacrylate), silicone, and AcrySof. J Cataract Refract Surg 23 (1997) 1532-1538
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1532-1538
    • Ursell, P.G.1    Spalton, D.J.2    Pande, M.V.3
  • 12
    • 13444311827 scopus 로고    scopus 로고
    • Intraocular lens factors that may affect anterior capsule contraction
    • Hayashi K., and Hayashi H. Intraocular lens factors that may affect anterior capsule contraction. Ophthalmology 112 (2005) 286-292
    • (2005) Ophthalmology , vol.112 , pp. 286-292
    • Hayashi, K.1    Hayashi, H.2
  • 13
    • 0031762312 scopus 로고    scopus 로고
    • Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome
    • Hayashi H., Hayashi K., Nakao F., and Hayashi F. Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome. Br J Ophthalmol 82 (1998) 1429-1432
    • (1998) Br J Ophthalmol , vol.82 , pp. 1429-1432
    • Hayashi, H.1    Hayashi, K.2    Nakao, F.3    Hayashi, F.4
  • 14
    • 0031709166 scopus 로고    scopus 로고
    • Anterior capsule contraction and intraocular lens dislocation after implant surgery in eyes with retinitis pigmentosa
    • Hayashi K., Hayashi H., Matsuo K., et al. Anterior capsule contraction and intraocular lens dislocation after implant surgery in eyes with retinitis pigmentosa. Ophthalmology 105 (1998) 1239-1243
    • (1998) Ophthalmology , vol.105 , pp. 1239-1243
    • Hayashi, K.1    Hayashi, H.2    Matsuo, K.3
  • 15
    • 0036142484 scopus 로고    scopus 로고
    • Risk factors for contraction of the anterior capsule opening after cataract surgery
    • Kato S., Suzuki T., Hayashi Y., et al. Risk factors for contraction of the anterior capsule opening after cataract surgery. J Cataract Refract Surg 28 (2002) 109-112
    • (2002) J Cataract Refract Surg , vol.28 , pp. 109-112
    • Kato, S.1    Suzuki, T.2    Hayashi, Y.3
  • 17
    • 0029924878 scopus 로고    scopus 로고
    • In vivo human lens epithelial cell proliferation on the anterior surface of PMMA intraocular lenses
    • Pande M.V., Spalton D.J., and Marshall J. In vivo human lens epithelial cell proliferation on the anterior surface of PMMA intraocular lenses. Br J Ophthalmol 80 (1996) 469-474
    • (1996) Br J Ophthalmol , vol.80 , pp. 469-474
    • Pande, M.V.1    Spalton, D.J.2    Marshall, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.