메뉴 건너뛰기




Volumn 21, Issue SUPPL. 1, 2006, Pages 94-98

Evaluation of a dual-panel PET camera design to breast cancer imaging

Author keywords

Breast cancer; Monte Carlo simulation; Position sensitive avalanche photodiode; Positron emission tomography

Indexed keywords

LUTETIUM; LUTETIUM OXYORTHOSILICATE; SILICATE; UNCLASSIFIED DRUG;

EID: 34247275746     PISSN: 11201797     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1120-1797(06)80035-9     Document Type: Conference Paper
Times cited : (1)

References (7)
  • 1
    • 2942711894 scopus 로고    scopus 로고
    • Instrumentation optimization for positron emission mammography
    • Moses WM and Qi J. Instrumentation optimization for positron emission mammography. Nucl. Inst. Meth. A. Vol. 527, pp. 76-82, 2004.
    • (2004) Nucl. Inst. Meth. A , vol.527 , pp. 76-82
    • Moses, W.M.1    Qi, J.2
  • 2
    • 0037457856 scopus 로고    scopus 로고
    • Fundamental limits of positron emission mammography
    • Moses WM and Qi J. Fundamental limits of positron emission mammography. Nucl. Inst. Meth. A. Vol. 497, pp. 82-89, 2003.
    • (2003) Nucl. Inst. Meth. A , vol.497 , pp. 82-89
    • Moses, W.M.1    Qi, J.2
  • 3
    • 0036815729 scopus 로고    scopus 로고
    • Comparison of rectangular and dual-planar positron emission mammography scanners
    • Oct
    • Qi. J, Kuo C, Huesman RH, Klein GJ, Moses WM, Reutter BW. Comparison of rectangular and dual-planar positron emission mammography scanners. IEEE Trans. Nucl. Sci., vol. 49, pp.2089-2096, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , pp. 2089-2096
    • Qi, J.1    Kuo, C.2    Huesman, R.H.3    Klein, G.J.4    Moses, W.M.5    Reutter, B.W.6
  • 4
    • 0033867215 scopus 로고    scopus 로고
    • Design and evaluation of an LSO PET detector for breast cancer imaging
    • July
    • Doshi. NK, Shao Y, Silverman RW, Cherry SR. Design and evaluation of an LSO PET detector for breast cancer imaging. Med. Phys. Vol. 27(7), pp. 1535-1543, July 2000.
    • (2000) Med. Phys , vol.27 , Issue.7 , pp. 1535-1543
    • Doshi, N.K.1    Shao, Y.2    Silverman, R.W.3    Cherry, S.R.4
  • 5
    • 0033864256 scopus 로고    scopus 로고
    • The potential role of positron emission mammography for detection of breast cancer. A phantom study
    • Aug
    • Raylman RR, Majewski S, Wojcik R, Weisengerger AG, Kross B, Popov V and Bishop HA. The potential role of positron emission mammography for detection of breast cancer. A phantom study. Med. Phys. Vol. 27(8), pp. 1943-1954, Aug. 2000.
    • (2000) Med. Phys , vol.27 , Issue.8 , pp. 1943-1954
    • Raylman, R.R.1    Majewski, S.2    Wojcik, R.3    Weisengerger, A.G.4    Kross, B.5    Popov, V.6    Bishop, H.A.7
  • 6
    • 3342880275 scopus 로고    scopus 로고
    • Investigation of position sensitive avalanche photodiodes for a new high-resolution PET detector design
    • June
    • Levin C S, Foudray A M K, Olcott P D, Habte F. Investigation of position sensitive avalanche photodiodes for a new high-resolution PET detector design. IEEE Trans. Nucl. Sci., vol. 51, pp.805-810, June 2004.
    • (2004) IEEE Trans. Nucl. Sci , vol.51 , pp. 805-810
    • Levin, C.S.1    Foudray, A.M.K.2    Olcott, P.D.3    Habte, F.4
  • 7
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratios using Noise Equivalent Counts
    • Apr
    • Strother S C, Casey M E and Hoffman E J. Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratios using Noise Equivalent Counts. IEEE Trans. Nucl. Sci., vol. 37, pp.783-788, Apr. 1990.
    • (1990) IEEE Trans. Nucl. Sci , vol.37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.