메뉴 건너뛰기




Volumn 68, Issue 1, 2007, Pages 301-310

Uncertainty Estimation in Intensity-Modulated Radiotherapy Absolute Dosimetry Verification

Author keywords

Intensity modulated radiotherapy; Radiotherapy quality assurance; Reference dosimetry; Small field dosimetry; Uncertainty estimation

Indexed keywords

IONIZATION CHAMBERS; MONTE CARLO METHODS; RADIOTHERAPY; UNCERTAINTY ANALYSIS;

EID: 34247256458     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2006.11.056     Document Type: Article
Times cited : (29)

References (32)
  • 1
    • 0029120085 scopus 로고
    • A Monte Carlo model of photon beams used in radiation therapy
    • Lovelock D.M., Chui C.S., and Mohan R. A Monte Carlo model of photon beams used in radiation therapy. Med Phys 22 (1995) 1387-1394
    • (1995) Med Phys , vol.22 , pp. 1387-1394
    • Lovelock, D.M.1    Chui, C.S.2    Mohan, R.3
  • 2
    • 0002204586 scopus 로고    scopus 로고
    • Conformal radiation therapy using a multileaf intensity modulating collimators
    • Sternic E.S. (Ed), Advanced Medical Publishing, Durango, CO
    • Curran B. Conformal radiation therapy using a multileaf intensity modulating collimators. In: Sternic E.S. (Ed). The theory and practice of intensity modulated radiation therapy (1997), Advanced Medical Publishing, Durango, CO 75-90
    • (1997) The theory and practice of intensity modulated radiation therapy , pp. 75-90
    • Curran, B.1
  • 3
    • 0032414728 scopus 로고    scopus 로고
    • Quantitative dosimetric verification of an IMRT planning and delivery system
    • Low D.A., Mutic S., Dempsey J.F., et al. Quantitative dosimetric verification of an IMRT planning and delivery system. Radiother Oncol 49 (1998) 305-316
    • (1998) Radiother Oncol , vol.49 , pp. 305-316
    • Low, D.A.1    Mutic, S.2    Dempsey, J.F.3
  • 4
    • 0034176959 scopus 로고    scopus 로고
    • Relative profile and dose verification of intensity-modulated radiation therapy
    • Chang J., Mageras G.S., Chui C.S., et al. Relative profile and dose verification of intensity-modulated radiation therapy. Int J Radiat Oncol Biol Phys 47 (2000) 231-240
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 231-240
    • Chang, J.1    Mageras, G.S.2    Chui, C.S.3
  • 5
    • 0034827572 scopus 로고    scopus 로고
    • Monte Carlo dose verification for intensity-modulated arc therapy
    • Li X.A., Ma L., Naqvi S., et al. Monte Carlo dose verification for intensity-modulated arc therapy. Phys Med Biol 46 (2001) 2269-2282
    • (2001) Phys Med Biol , vol.46 , pp. 2269-2282
    • Li, X.A.1    Ma, L.2    Naqvi, S.3
  • 6
    • 0035024471 scopus 로고    scopus 로고
    • Monte Carlo simulation for MLC-based intensity-modulated radiotherapy
    • Pawlicki T., and Ma C.M. Monte Carlo simulation for MLC-based intensity-modulated radiotherapy. Med Dosim 26 (2001) 157-168
    • (2001) Med Dosim , vol.26 , pp. 157-168
    • Pawlicki, T.1    Ma, C.M.2
  • 7
    • 0002908171 scopus 로고
    • Photon beam dose calculations
    • Mackie T.R., and Palta J.R. (Eds), Advanced Medical Publishing, Madison, WI
    • Mackie T.R., Reckwerdt P., McNutt T., et al. Photon beam dose calculations. In: Mackie T.R., and Palta J.R. (Eds). Teletherapy: Present and future (1995), Advanced Medical Publishing, Madison, WI 103-135
    • (1995) Teletherapy: Present and future , pp. 103-135
    • Mackie, T.R.1    Reckwerdt, P.2    McNutt, T.3
  • 8
    • 0029865277 scopus 로고    scopus 로고
    • Dosimetric verification of intensity modulated fields
    • Wang X., Spirou S., LoSasso T., et al. Dosimetric verification of intensity modulated fields. Med Phys 23 (1996) 317-328
    • (1996) Med Phys , vol.23 , pp. 317-328
    • Wang, X.1    Spirou, S.2    LoSasso, T.3
  • 9
    • 0032708803 scopus 로고    scopus 로고
    • Diamond detector measurements near simulated air channels for narrow photon beams
    • De Vlamynck K., De Wagter C., and De Neve W. Diamond detector measurements near simulated air channels for narrow photon beams. Radiother Oncol 53 (1999) 155-159
    • (1999) Radiother Oncol , vol.53 , pp. 155-159
    • De Vlamynck, K.1    De Wagter, C.2    De Neve, W.3
  • 10
    • 0033795118 scopus 로고    scopus 로고
    • The value of the Pinpoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy
    • Martens C., De Wagter C., and De Neve W. The value of the Pinpoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy. Phys Med Biol 45 (2000) 2519-2530
    • (2000) Phys Med Biol , vol.45 , pp. 2519-2530
    • Martens, C.1    De Wagter, C.2    De Neve, W.3
  • 11
    • 0037037135 scopus 로고    scopus 로고
    • A method for photon beam Monte Carlo multileaf collimator particle transport
    • Siebers J.V., Keall P.J., Kim J.O., et al. A method for photon beam Monte Carlo multileaf collimator particle transport. Phys Med Biol 47 (2002) 3225-3249
    • (2002) Phys Med Biol , vol.47 , pp. 3225-3249
    • Siebers, J.V.1    Keall, P.J.2    Kim, J.O.3
  • 12
    • 0001512274 scopus 로고
    • A theory of cavity ionization
    • Spencer L.V., and Attix F.H. A theory of cavity ionization. Radiat Res 3 (1955) 239-254
    • (1955) Radiat Res , vol.3 , pp. 239-254
    • Spencer, L.V.1    Attix, F.H.2
  • 13
    • 0035889335 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy: Current status and issues of interest
    • Boyer A.L., Butler E.B., DiPetrillo T.A., et al. Intensity-modulated radiotherapy: Current status and issues of interest. Int J Radiat Oncol Biol Phys 51 (2001) 880-914
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 880-914
    • Boyer, A.L.1    Butler, E.B.2    DiPetrillo, T.A.3
  • 14
    • 10744230395 scopus 로고    scopus 로고
    • Ionization chamber dosimetry of small photon fields: A Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams
    • Sánchez-Doblado F., Andreo P., Capote R., et al. Ionization chamber dosimetry of small photon fields: A Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams. Phys Med Biol 48 (2003) 2081-2099
    • (2003) Phys Med Biol , vol.48 , pp. 2081-2099
    • Sánchez-Doblado, F.1    Andreo, P.2    Capote, R.3
  • 16
    • 0037323117 scopus 로고    scopus 로고
    • Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter)
    • Paskalev K.A., Seuntjens J.P., Patrocinio H.J., et al. Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter). Med Phys 30 (2002) 111-118
    • (2002) Med Phys , vol.30 , pp. 111-118
    • Paskalev, K.A.1    Seuntjens, J.P.2    Patrocinio, H.J.3
  • 17
    • 0037150013 scopus 로고    scopus 로고
    • Evaluation of the EGSnrc Monte Carlo code for interface dosimetry near high-Z media exposed to kilovolt and 60Co photons
    • Verhaegen F. Evaluation of the EGSnrc Monte Carlo code for interface dosimetry near high-Z media exposed to kilovolt and 60Co photons. Phys Med Biol 47 (2002) 1691-1705
    • (2002) Phys Med Biol , vol.47 , pp. 1691-1705
    • Verhaegen, F.1
  • 18
    • 4644300643 scopus 로고    scopus 로고
    • An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets
    • Capote R., Sánchez-Doblado F., Leal A., et al. An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets. Med Phys 31 (2004) 2416-2422
    • (2004) Med Phys , vol.31 , pp. 2416-2422
    • Capote, R.1    Sánchez-Doblado, F.2    Leal, A.3
  • 19
    • 4644295340 scopus 로고    scopus 로고
    • Ionization chamber-based reference dosimetry of intensity modulated radiation beams
    • Bouchard H., and Seuntjens J. Ionization chamber-based reference dosimetry of intensity modulated radiation beams. Med Phys 31 (2004) 2454-2465
    • (2004) Med Phys , vol.31 , pp. 2454-2465
    • Bouchard, H.1    Seuntjens, J.2
  • 20
    • 4644331449 scopus 로고    scopus 로고
    • Electron beam quality correction factors for plane-parallel ionization chambers: Monte Carlo calculations using the PENELOPE system
    • Sempau J., Andreo P., Aldana J., et al. Electron beam quality correction factors for plane-parallel ionization chambers: Monte Carlo calculations using the PENELOPE system. Phys Med Biol 49 (2004) 4427-4444
    • (2004) Phys Med Biol , vol.49 , pp. 4427-4444
    • Sempau, J.1    Andreo, P.2    Aldana, J.3
  • 21
    • 16444362815 scopus 로고    scopus 로고
    • Microionization chamber for reference dosimetry in IMRT verification: Clinical implications on OAR dosimetric errors
    • Sánchez-Doblado F., Capote R., Leal A., et al. Microionization chamber for reference dosimetry in IMRT verification: Clinical implications on OAR dosimetric errors. Phys Med Biol 50 (2005) 959-970
    • (2005) Phys Med Biol , vol.50 , pp. 959-970
    • Sánchez-Doblado, F.1    Capote, R.2    Leal, A.3
  • 22
    • 16444377303 scopus 로고    scopus 로고
    • Micro ionization chamber dosimetry in IMRT verification: Clinical implications of dosimetric errors in the PTV
    • Sánchez-Doblado F., Capote R., Leal A., et al. Micro ionization chamber dosimetry in IMRT verification: Clinical implications of dosimetric errors in the PTV. Radiother Oncol 75 (2005) 342-348
    • (2005) Radiother Oncol , vol.75 , pp. 342-348
    • Sánchez-Doblado, F.1    Capote, R.2    Leal, A.3
  • 23
    • 0033695030 scopus 로고    scopus 로고
    • PTW-diamond detector: Dose rate and particle type dependence
    • A
    • Fidanzio A., Azario L., Miceli R., et al. PTW-diamond detector: Dose rate and particle type dependence. A. Med Phys 11 (2000) 2589-2593
    • (2000) Med Phys , vol.11 , pp. 2589-2593
    • Fidanzio, A.1    Azario, L.2    Miceli, R.3
  • 25
    • 0029035150 scopus 로고
    • BEAM: A Monte Carlo code to simulate radiotherapy treatment units
    • Rogers D.W.O., Faddegon B.A., Ding G.X., et al. BEAM: A Monte Carlo code to simulate radiotherapy treatment units. Med Phys 22 (1995) 503-524
    • (1995) Med Phys , vol.22 , pp. 503-524
    • Rogers, D.W.O.1    Faddegon, B.A.2    Ding, G.X.3
  • 27
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • Kawrakow I. Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. Med Phys 27 (2000) 485-498
    • (2000) Med Phys , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 28
    • 0345701465 scopus 로고    scopus 로고
    • Routine IMRT verification by means of an automatic MC simulation system
    • Leal A., Sánchez-Doblado F., Arráns R., et al. Routine IMRT verification by means of an automatic MC simulation system. Int J Radiat Oncol Phys 65 (2003) 58-68
    • (2003) Int J Radiat Oncol Phys , vol.65 , pp. 58-68
    • Leal, A.1    Sánchez-Doblado, F.2    Arráns, R.3
  • 29
    • 34247281209 scopus 로고    scopus 로고
    • Dynamic IMRT segment optimisation for a faster MC verification
    • [Abstract]
    • Lagares J.I., Leal A., Sánchez-Doblado F., et al. Dynamic IMRT segment optimisation for a faster MC verification. [Abstract]. Radiother Oncol 68 Suppl. 1 (2003) S91-S92
    • (2003) Radiother Oncol , vol.68 , Issue.SUPPL. 1
    • Lagares, J.I.1    Leal, A.2    Sánchez-Doblado, F.3
  • 30
    • 7244223252 scopus 로고    scopus 로고
    • Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting
    • Kawrakow I., Rogers D.W.O., and Walters B.R.B. Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting. Med Phys 31 (2004) 2883-2898
    • (2004) Med Phys , vol.31 , pp. 2883-2898
    • Kawrakow, I.1    Rogers, D.W.O.2    Walters, B.R.B.3
  • 32
    • 2542506565 scopus 로고    scopus 로고
    • Monitor unit calculation for Monte Carlo treatment planning
    • Ma C.-M., Price Jr. R.A., Li J.S., et al. Monitor unit calculation for Monte Carlo treatment planning. Phys Med Biol 49 (2004) 1671-1687
    • (2004) Phys Med Biol , vol.49 , pp. 1671-1687
    • Ma, C.-M.1    Price Jr., R.A.2    Li, J.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.